Angle vs. LabSOCS for HPGe efficiency calibration

被引:9
|
作者
Stanic, Goran [1 ]
Nikolov, Jovana [1 ]
Tucakovic, Ivana [2 ]
Mrda, Dusan [1 ]
Todorovic, Natasa [1 ]
Grahek, Zeljko [2 ]
Coha, Ivana [2 ]
Vranicar, Andrei [1 ]
机构
[1] Univ Novi Sad, Fac Sci, Novi Sad, Serbia
[2] Rudjer Boskovic Inst, Zagreb, Croatia
关键词
Efficiency calibration; Angle; LabSOCS; Gamma spectrometry; ENVIRONMENTAL-SAMPLES; PEAK EFFICIENCY; GAMMA; SOFTWARE; DETECTOR; SIMULATION; EFFTRAN; ENERGY;
D O I
10.1016/j.nima.2018.12.059
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The quantitative determination of radionuclides by gamma ray spectrometry requires a high accuracy of detection efficiency determination. Different software codes for efficiency determination are available. The aim of this work was to compare different methods and software used for efficiency calibration modeling and analyses. For that purpose, same samples of vegetation and soil of known activities were measured using HPGe detectors in two laboratories which are employing different software for mathematical efficiency calibrations and analyses, LabSOCS which is based on purely mathematical calculations and Angle which uses a semi-empirical approach. The codes were also tested on samples with unknown reference values (different geometries and matrices). The main advantages and disadvantages of both software were compared. Both Angle and LabSOCS gave comparable and consistent results for different detectors, matrices and geometries used. Deviations of the order of 10% or less obtained from the comparison of different sets of parameters are acceptable and imply that Angle and LabSOCS can be considered reliable for gamma ray detector efficiency calibrations. The main limitation of LabSOCS is in its inability to be used on newly installed detectors (factory characterization needed first), as for Angle the main drawback is in its demand for reference materials which can be costly as well as the need for plenty detector characteristics which are not always provided by the manufacturer.
引用
收藏
页码:81 / 87
页数:7
相关论文
共 50 条
  • [21] Monte Carlo based geometrical model for efficiency calculation of an n-type HPGe detector
    Padilla Cabal, Fatima
    Lopez-Pino, Neivy
    Luis Bernal-Castillo, Jose
    Martinez-Palenzuela, Yisel
    Aguilar-Mena, Jimmy
    D'Alessandro, Katia
    Arbelo, Yuniesky
    Corrales, Yasser
    Diaz, Oscar
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (12) : 2403 - 2408
  • [22] Efficiency calibration of an HPGe X-ray detector for quantitative PIXE analysis
    Mulware, Stephen J.
    Baxley, Jacob D.
    Rout, Bibhudutta
    Reinert, Tilo
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2014, 332 : 95 - 98
  • [23] Efficiency calibration of a coaxial HPGe detector-Marinelli beaker geometry using an 152Eu source prepared in epoxy matrix and its validation by efficiency transfer method
    Yucel, Haluk
    Zumrut, Senem
    Nartturk, Recep Bora
    Gedik, Gizem
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2019, 51 (02) : 526 - 532
  • [24] Efficiency calibration technology of 133Xe gas by efficiency transfer code of 133Ba disk source for HPGe detector
    Tian, Zining
    Ouyang, Xiaoping
    Liu, Yang
    Zhang, Xiaodong
    Liu, Linyue
    Zhang, Jianfu
    Liu, Jun
    Ruan, Jinlu
    Zhang, Zhongbing
    Zeng, Ming
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2014, 26 (09):
  • [25] A fitting algorithm based on simulated annealing techniques for efficiency calibration of HPGe detectors using different mathematical functions
    Hurtado, S.
    Garcia-Leon, M.
    Garcia-Tenorio, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 594 (03) : 362 - 367
  • [26] CREPT-MCNP code for efficiency calibration of HPGe detectors with the representative point method
    Saegusa, Jun
    APPLIED RADIATION AND ISOTOPES, 2008, 66 (6-7) : 774 - 779
  • [27] Self-attenuation corrections calculated by LabSOCS Simulations for gamma-spectrometric measurements with HPGe detectors
    Tian Zi-Ning
    Ouyang Xiao-Ping
    Liu Yang
    Chen Liang
    Liu Jin-Liang
    Zhang Xian-Peng
    Song Ji-Wen
    Zeng Ming
    CHINESE PHYSICS C, 2014, 38 (07)
  • [28] Self-attenuation corrections calculated by LabSOCS Simulations for gamma-spectrometric measurements with HPGe detectors
    田自宁
    欧阳晓平
    刘洋
    陈亮
    刘金良
    张显鹏
    宋纪文
    曾鸣
    Chinese Physics C, 2014, 38 (07) : 88 - 93
  • [29] A semi-empirical method for efficiency calibration of an HPGe detector against different sample densities
    Nabil, Islam M.
    El-Kourghly, K. M.
    El Sayed, A. F.
    APPLIED RADIATION AND ISOTOPES, 2023, 200
  • [30] A proposal to design a new high volume standard air filter for efficiency calibration of HPGe detector
    Mahdi Tourang
    Asghar Hadadi
    Mitra Athari Allaf
    Dariush Sardari
    Journal of Radioanalytical and Nuclear Chemistry, 2021, 327 : 345 - 352