Angle vs. LabSOCS for HPGe efficiency calibration

被引:9
|
作者
Stanic, Goran [1 ]
Nikolov, Jovana [1 ]
Tucakovic, Ivana [2 ]
Mrda, Dusan [1 ]
Todorovic, Natasa [1 ]
Grahek, Zeljko [2 ]
Coha, Ivana [2 ]
Vranicar, Andrei [1 ]
机构
[1] Univ Novi Sad, Fac Sci, Novi Sad, Serbia
[2] Rudjer Boskovic Inst, Zagreb, Croatia
关键词
Efficiency calibration; Angle; LabSOCS; Gamma spectrometry; ENVIRONMENTAL-SAMPLES; PEAK EFFICIENCY; GAMMA; SOFTWARE; DETECTOR; SIMULATION; EFFTRAN; ENERGY;
D O I
10.1016/j.nima.2018.12.059
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The quantitative determination of radionuclides by gamma ray spectrometry requires a high accuracy of detection efficiency determination. Different software codes for efficiency determination are available. The aim of this work was to compare different methods and software used for efficiency calibration modeling and analyses. For that purpose, same samples of vegetation and soil of known activities were measured using HPGe detectors in two laboratories which are employing different software for mathematical efficiency calibrations and analyses, LabSOCS which is based on purely mathematical calculations and Angle which uses a semi-empirical approach. The codes were also tested on samples with unknown reference values (different geometries and matrices). The main advantages and disadvantages of both software were compared. Both Angle and LabSOCS gave comparable and consistent results for different detectors, matrices and geometries used. Deviations of the order of 10% or less obtained from the comparison of different sets of parameters are acceptable and imply that Angle and LabSOCS can be considered reliable for gamma ray detector efficiency calibrations. The main limitation of LabSOCS is in its inability to be used on newly installed detectors (factory characterization needed first), as for Angle the main drawback is in its demand for reference materials which can be costly as well as the need for plenty detector characteristics which are not always provided by the manufacturer.
引用
收藏
页码:81 / 87
页数:7
相关论文
共 50 条
  • [1] Calibration and Performance of HPGe Detector for Environmental Radioactivity Measurements using LabSOCS
    Shyti, Manjola
    10TH JUBILEE CONFERENCE OF THE BALKAN PHYSICAL UNION, 2019, 2075
  • [2] A new and general efficiency calibration methodology for Ge detectors using LabSOCS
    Barba-Lobo, A.
    RADIATION MEASUREMENTS, 2025, 181
  • [3] An investigation of HPGe gamma efficiency calibration software (ANGLE V.3) for applications in nuclear decommissioning
    Bell, S. J.
    Judge, S. M.
    Regan, P. H.
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (12) : 2737 - 2741
  • [4] Development of an absolute method for efficiency calibration of a coaxial HPGe detector for large volume sources
    Ortiz-Ramirez, Pablo C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 793 : 49 - 56
  • [5] A simple method for efficiency calibration of HPGe detectors in γ-spectrometric measurements
    Pérez-Moreno, JP
    Bolívar, JP
    García-Tenorio, R
    Miguel, ES
    Aguado, JL
    Mas, JL
    Vaca, F
    RADIATION PHYSICS AND CHEMISTRY, 2001, 61 (3-6) : 437 - 438
  • [6] Efficiency calibration of HPGe detector in a PGNAA system for the measurement of aqueous samples
    Cheng, Can
    Jia, Wenbao
    Hei, Daqian
    Li, Jiatong
    Cai, Pingkun
    Zhao, Dong
    Wei, Zhiyong
    APPLIED RADIATION AND ISOTOPES, 2019, 145 : 1 - 6
  • [7] Semiempirical Efficiency Calibration in Semiconductor HPGe Gamma-Ray Spectroscopy
    Nikolic, Jelena Krneta
    Rajacic, Milica
    Todorovic, Dragana
    Jankovic, Marija
    Sarap, Natasa
    Pantelic, Gordana
    Vukanac, Ivana
    JOURNAL OF SPECTROSCOPY, 2018, 2018
  • [8] Gamma spectrometry and LabSOCS-calculated efficiency in the radiological characterisation of quadrangular and cubic specimens of hardened portland cement paste
    Suarez-Navarro, J. A.
    Moreno-Reyes, A. M.
    Gasco, C.
    Alonso, M. M.
    Puertas, F.
    RADIATION PHYSICS AND CHEMISTRY, 2020, 171
  • [9] Robustness of LabSOCS calculating Ge detector efficiency for the measurement of radionuclides
    Barba-Lobo, A.
    Exposito-Suarez, V. M.
    Suarez-Navarro, J. A.
    Bolivar, J. P.
    RADIATION PHYSICS AND CHEMISTRY, 2023, 205
  • [10] Efficiency calibration of a HPGe detector for the measurement of the primary coolant
    Qin, Guoxiu
    Liu, Yujuan
    Wu, Hexi
    Zhang, Huaiqiang
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2016, 310 (03) : 1033 - 1040