Index matching to improve optical coherence tomography imaging through blood

被引:1
作者
Brezinski, M
Saunders, K
Jesser, C
Li, XD
Fujimoto, J
机构
[1] MIT, Dept Elect Engn & Comp Sci, Cambridge, MA 02139 USA
[2] Harvard Univ, Brigham & Womens Hosp, Sch Med, Dept Orthoped, Boston, MA 02115 USA
关键词
tomography; plaque; myocardial infarction; blood; imaging;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Most myocardial infarctions are caused by the rupture of small rather than large plaques in the arteries of the heart that are beyond the detection limit of current technologies. Methods and Results-Recently, optical coherence tomography (OCT) has demonstrated considerable potential as a method for high-resolution assessment of vulnerable plaque. However, intravascular OCT imaging is complicated by the need to remove blood from the imaging field because blood results in substantial signal attenuation. This work examines index matching as a method for increasing penetration. Index matching is based on the hypothesis that the predominant source of scattering in blood is the difference in refractive index between the cytoplasm of erythrocytes and serum. By increasing the refractive index of serum to a value near that of the cytoplasm, or index matching, scattering can be substantially reduced. The concept was tested with a system that pumped blood in vitro through transparent tubing. The test compounds, dextran and intravenous contrast agent, both led to significant improvements in penetration (69 +/- 12% and 45 +/-4%). No significant effect was seen with the saline control. For dextran, the effect could not be attributed to reductions of red cell number or volume because changes in these parameters were not different from the control. In the case of intravenous contrast, a small but significant relative reduction in red cell volume was seen. Conclusions-This study demonstrates the feasibility of index matching for improving OCT imaging through blood. Future studies are required to identify compounds for effective index matching in vivo.
引用
收藏
页码:1999 / 2003
页数:5
相关论文
共 21 条
[1]   ANGIOGRAPHIC PROGRESSION OF CORONARY-ARTERY DISEASE AND THE DEVELOPMENT OF MYOCARDIAL-INFARCTION [J].
AMBROSE, JA ;
TANNENBAUM, MA ;
ALEXOPOULOS, D ;
HJEMDAHLMONSEN, CE ;
LEAVY, J ;
WEISS, M ;
BORRICO, S ;
GORLIN, R ;
FUSTER, V .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 12 (01) :56-62
[2]  
[Anonymous], 1987, ELECTROMAGNETIC ACOU
[3]  
Beauvoit B, 1993, Cell Biophys, V23, P91
[4]   Optical coherence tomography for optical biopsy - Properties and demonstration of vascular pathology [J].
Brezinski, ME ;
Tearney, GJ ;
Bouma, BE ;
Izatt, JA ;
Hee, MR ;
Swanson, EA ;
Southern, JF ;
Fujimoto, JG .
CIRCULATION, 1996, 93 (06) :1206-1213
[5]   Assessing atherosclerotic plaque morphology: Comparison of optical coherence tomography and high frequency intravascular ultrasound [J].
Brezinski, ME ;
Tearney, GJ ;
Weissman, NJ ;
Boppart, SA ;
Bouma, BE ;
Hee, MR ;
Weyman, AE ;
Swanson, EA ;
Southern, JF ;
Fujimoto, JG .
HEART, 1997, 77 (05) :397-403
[6]   EFFECTS OF SOLUTES ON OPTICAL-PROPERTIES OF BIOLOGICAL-MATERIALS - MODELS, CELLS, AND TISSUES [J].
CHANCE, B ;
LIU, HL ;
KITAI, T ;
ZHANG, YT .
ANALYTICAL BIOCHEMISTRY, 1995, 227 (02) :351-362
[7]   Sources of contrast in confocal reflectance imaging [J].
Dunn, AK ;
Smithpeter, C ;
Welch, AJ ;
RichardsKortum, R .
APPLIED OPTICS, 1996, 35 (19) :3441-3446
[8]  
FALK E, 1983, BRIT HEART J, V50, P127
[9]   High resolution in vivo intra-arterial imaging with optical coherence tomography [J].
Fujimoto, JG ;
Boppart, SA ;
Tearney, GJ ;
Bouma, BE ;
Pitris, C ;
Brezinski, ME .
HEART, 1999, 82 (02) :128-133
[10]   REDUCED LIGHT-SCATTERING PROPERTIES FOR MIXTURES OF SPHERICAL-PARTICLES - A SIMPLE APPROXIMATION DERIVED FROM MIE CALCULATIONS [J].
GRAAFF, R ;
AARNOUDSE, JG ;
ZIJP, JR ;
SLOOT, PMA ;
DEMUL, FFM ;
GREVE, J ;
KOELINK, MH .
APPLIED OPTICS, 1992, 31 (10) :1370-1376