Aim. The aim of this in vitro study was to compare the two-body wear resistance of substructure zirconia and veneering porcelain versus steatite and human enamel antagonists, respectively. Materials and methods. Two-body wear tests were performed in a chewing simulator with steatite and enamel antagonists (enamel cusps). A pin-on-block design with a vertical load of 50 N for 1.2 x 10(5) cycles; (f = 1.6 Hz; lateral movement: 1 mm, mouth opening: 2 mm) was used for the wear test. For quantification of the wear resistance, wear tests were performed with standardized steatite spheres. Human enamel was used as a reference. Five zirconia ceramics and four veneering porcelains were investigated. One zirconia ceramic was tested with superficial glaze, which was applied after polishing or sandblasting, respectively. Surface roughness R(a) (SP6, Perthen-Feinpruf, G) and wear depth were determined using a 3D-Profilometer (Laserscan 3D, Willytec, G). SEM (Quanta FEG 400, FEI, USA) pictures were used for evaluating wear performance of both, ceramics and antagonists. Results. No wear was found for zirconia substructures. Veneering porcelain provided wear traces between 186.1 +/- 33.2 mu m and 232.9 +/- 66.9 mu m (steatite antagonist) and 90.6 +/- 3.5 mu m and 123.9 +/- 50.7 mu m (enamel). Wear of the steatite antagonists varied between 0.812 +/- 0.256 mm(2) and 1.360 +/- 0.321 mm(2) for zirconia and 1.708 +/- 0.275 mm(2) and 2.568 +/- 0.827 mm(2) for porcelain. Enamel generally showed wear, cracks or even fractures at the ridge, regardless whether opposed by zirconia or porcelain/glaze. Enamel was polished, when opposed to zirconia, or plowed, provoked and grinded, when opposed to porcelain/glaze. Conclusion. The results of the wear test with steatite or enamel antagonists indicated no measurable wear on zirconia surfaces. Porcelain showed higher wear than zirconia, but comparable or lower wear than an enamel reference. Antagonistic wear against zirconia was found to be lower than wear against porcelain. (C) 2011 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:796 / 804
页数:9
相关论文
共 50 条
  • [1] Wear Performance of Dental Materials: A Comparison of Substructure Ceramics, Veneering Ceramics, and Non-Precious Alloys
    Preis, Verena
    Hahnel, Sebastian
    Kolbeck, Carola
    Behrend, Detlef
    Warkentin, Mareike
    Handel, Gerhard
    Rosentritt, Martin
    ADVANCED ENGINEERING MATERIALS, 2011, 13 (12) : B432 - B439
  • [2] Two-body wear of dental porcelain and substructure oxide ceramics
    Rosentritt, Martin
    Preis, Verena
    Behr, Michael
    Hahnel, Sebastian
    Handel, Gerhard
    Kolbeck, Carola
    CLINICAL ORAL INVESTIGATIONS, 2012, 16 (03) : 935 - 943
  • [3] Wear performance of dental ceramics after grinding and polishing treatments
    Preis, Verena
    Behr, Michael
    Handel, Gerhard
    Schneider-Feyrer, Sibylle
    Hahnel, Sebastian
    Rosentritt, Martin
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2012, 10 : 13 - 22
  • [4] Investigation on the Tribological Behavior and Wear Mechanism of Five Different Veneering Porcelains
    Min, Jie
    Zhang, Qianqian
    Qiu, Xiaoli
    Zhu, Minhao
    Yu, Haiyang
    Gao, Shanshan
    PLOS ONE, 2015, 10 (09):
  • [5] Two-body wear of dental porcelain and substructure oxide ceramics
    Martin Rosentritt
    Verena Preis
    Michael Behr
    Sebastian Hahnel
    Gerhard Handel
    Carola Kolbeck
    Clinical Oral Investigations, 2012, 16 : 935 - 943
  • [6] Wear evaluation of the human enamel opposing different Y-TZP dental ceramics and other porcelains
    Kim, Mi-Jin
    Oh, Sun-Hee
    Kim, Ji-Hwan
    Ju, Sung-Won
    Seo, Deog-Gyu
    Jun, Sang-Ho
    Ahn, Jin-Soo
    Ryu, Jae-Jun
    JOURNAL OF DENTISTRY, 2012, 40 (11) : 979 - 988
  • [7] In vitro evaluation of shear bond strength of veneering ceramics to zirconia
    Ozkurt, Zeynep
    Kazazoglu, Ender
    Unal, Ahmet
    DENTAL MATERIALS JOURNAL, 2010, 29 (02) : 138 - 146
  • [8] Wear behavior of enamel/dentine and veneering ceramics
    Gao, Q. P.
    Chao, Y. L.
    Jian, X. C. H.
    Guo, F.
    Meng, Y. K.
    Wang, H.
    Cui, J.
    Zhang, W. Q.
    Tian, Y. F.
    BIOCERAMICS, VOL 19, PTS 1 AND 2, 2007, 330-332 : 1251 - +
  • [9] Flexural Strength of Glass-Infiltrated Zirconia/Alumina-Based Ceramics and Feldspathic Veneering Porcelains
    Bottino, Marco Antonio
    Salazar-Marocho, Susana M.
    Leite, Fabiola P. P.
    Vasquez, Vanessa C.
    Valandro, Luiz Felipe
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2009, 18 (05): : 417 - 420
  • [10] In Vitro Adherence of Oral Streptococci to Zirconia Core and Veneering Glass-Ceramics
    Rosentritt, Martin
    Behr, Michael
    Buergers, Ralf
    Feilzer, Albert J.
    Hahnel, Sebastian
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2009, 91B (01) : 257 - 263