A double-vented tetraphasic continuous column approach to MuDPIT analysis on long capillary columns demonstrates superior proteomic coverage

被引:20
作者
Guzzetta, AW [1 ]
Chien, AS [1 ]
机构
[1] Stanford Univ, Vincent Coates Fdn, Mass Spectrometry Lab, Stanford, CA 94305 USA
关键词
MuDPIT; vented column; V-column; multidimensional chromatography; long capillary column; serum proteomics;
D O I
10.1021/pr050209h
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A double-vented serial tetraphasic capillary column approach is applied to proteomic MuDPIT-type analysis using extended length capillary reverse-phase columns. The heart of the tetraphasic device consists of a triphasic MuDPIT trap located upstream of a venting tee. The trap is followed by a 60 cm high-resolution capillary column. A conventional high-flow HPLC is used to develop gradients at standard flow rates and pressures. The double-vented triphasic MuDPIT trapping device relieves the capillary separation column from the salt burden during the on-line cation-exchange portion of the analysis. Two configurations are presented, a double-vented continuous column model and a discontinuous model in which the triphasic MuDPIT trap is installed on a six-port valve; both configurations were tested with 60 and 10 cm capillary columns. All four systems were challenged with a trypsin digest of undepleted human serum, and a matrix of proteomic results for the different models and column lengths are compared.
引用
收藏
页码:2412 / 2419
页数:8
相关论文
共 23 条
[1]   A multidimensional approach to protein characterization [J].
Anderegg, RJ ;
Wagner, DS ;
Blackburn, RK ;
Opiteck, GJ ;
Jorgenson, JW .
JOURNAL OF PROTEIN CHEMISTRY, 1997, 16 (05) :523-526
[2]   AUTOMATED INSTRUMENTATION FOR COMPREHENSIVE 2-DIMENSIONAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PROTEINS [J].
BUSHEY, MM ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1990, 62 (02) :161-167
[3]   Instrumental requirements for nanoscale liquid chromatography [J].
Chervet, JP ;
Ursem, M ;
Salzmann, JB .
ANALYTICAL CHEMISTRY, 1996, 68 (09) :1507-1512
[4]  
CHIEN AS, 2004, 52 ASMS C MASS SPECT
[5]   SEPARATION OF NANOLITER SAMPLES OF BIOLOGICAL AMINES BY A COMPREHENSIVE 2-DIMENSIONAL MICROCOLUMN LIQUID-CHROMATOGRAPHY SYSTEM [J].
HOLLAND, HA ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1995, 67 (18) :3275-3283
[6]   FAST LIQUID CHROMATOGRAPHY - AN INVESTIGATION OF OPERATING PARAMETERS AND SEPARATION OF NUCLEOTIDES ON PELLICULAR ION EXCHANGERS [J].
HORVATH, CG ;
PREISS, BA ;
LIPSKY, SR .
ANALYTICAL CHEMISTRY, 1967, 39 (12) :1422-&
[7]   2-DIMENSIONAL SEPARATIONS OF PEPTIDES AND PROTEINS BY COMPREHENSIVE LIQUID-CHROMATOGRAPHY CAPILLARY-ELECTROPHORESIS [J].
LARMANN, JP ;
LEMMO, AV ;
MOORE, AW ;
JORGENSON, JW .
ELECTROPHORESIS, 1993, 14 (5-6) :439-447
[8]   Automation of nanoscale microcapillary liquid chromatography-tandem mass spectromentry with a vented column [J].
Licklider, LJ ;
Thoreen, CC ;
Peng, JM ;
Gygi, SP .
ANALYTICAL CHEMISTRY, 2002, 74 (13) :3076-3083
[9]   Comparison of three directly coupled HPLC MS/MS strategies for identification of proteins from complex mixtures: single-dimension LC-MS/MS, 2-phase MudPIT, and 3-phase MudPIT [J].
McDonald, WH ;
Ohi, R ;
Miyamoto, DT ;
Mitchison, TJ ;
Yates, JR .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2002, 219 (01) :245-251
[10]  
Meiring HD, 2002, J SEP SCI, V25, P557, DOI 10.1002/1615-9314(20020601)25:9<557::AID-JSSC557>3.0.CO