Enantiomeric separation of asymmetric triacylglycerol by recycle high-performance liquid chromatography with chiral column

被引:51
|
作者
Nagai, Toshiharu [1 ]
Mizobe, Hoyo
Otake, Ikuko
Ichioka, Kenji
Kojima, Koichi
Matsumoto, Yumiko [2 ]
Gotoh, Naohiro [2 ]
Kuroda, Ikuma [3 ]
Wada, Shun [2 ]
机构
[1] Tsukishima Foods Ind Co Ltd, R&D Div, Edogawa Ku, Tokyo 1348520, Japan
[2] Tokyo Univ Marine Sci & Technol, Dept Food Sci & Technol, Tokyo 1088477, Japan
[3] GL Sci Inc, Tokyo 1631130, Japan
关键词
Chiral column; Enantiomer; Recycle HPLC; Resolution; Triacylglycerol; TRIACYL-SN-GLYCEROLS; POLYUNSATURATED FATTY-ACIDS; POLYMERIC ODS COLUMN; STEREOSPECIFIC ANALYSIS; POSITIONAL DISTRIBUTION; STATIONARY-PHASE; TRIGLYCERIDE STRUCTURE; EICOSANOID PRODUCTION; LIPID-METABOLISM; VEGETABLE-OILS;
D O I
10.1016/j.chroma.2011.02.067
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In our previous studies, we employed recycle HPLC for the separation of triacylglycerol (TAG)-positional isomers (Pis). In this study, a recycle HPLC system equipped with a polysaccharide-based chiral column was applied to the enantiomeric separation of some asymmetric TAGs having straight-chain C16-C18 acyl residues. As a result, 1,2-dipalmitoyl-3-oleoyl-rac-glycerol (rac-PPO), 1,2-dioleoyl-3-palmitoyl-rac-glycerol (rac-OOP), and 1,2-dipalmitoyl-3-linoleoyl-rac-glycerol (rac-PPL) were resolved into their respective enantiomers. However, neither 1,2-dioleoyl-3-linoleoyl-rac-glycerol (rac-OOL), consisting of only unsaturated fatty acids, nor 1,2-dipalmitoyl-3-stearoyl-rac-glycerol (rac-PPS), consisting of only saturated fatty acids, was resolved. These results suggest that the asymmetric TAGs, used in this study, having both a palmitic acid moiety and an oleic acid (or a linoleic acid) moiety at the sn-1 or sn-3 positions are resolved by the chiral column. This new chiral separation method can be used in combination with atmospheric pressure chemical ionization mass spectrometry to determine the sn-OOP/sn-POO ratio in palm oil. This method is applicable for the chiral separation of asymmetric TAGs in palm oil. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:2880 / 2886
页数:7
相关论文
共 50 条
  • [21] Resolution of enantiomeric steroids by high-performance liquid chromatography on chiral stationary phases
    Kummer, M
    Palme, HJ
    Werner, G
    JOURNAL OF CHROMATOGRAPHY A, 1996, 749 (1-2) : 61 - 68
  • [22] DIRECT ENANTIOMERIC SEPARATION OF CIS-(+/-)DILTIAZEM IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH OVOMUCOID COLUMN
    ROSELL, G
    CAMACHO, A
    PARRA, P
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 619 (01): : 87 - 92
  • [23] Determination of enantiomeric excess of dextropropoxyphene and α-(+)-oxyphene by chiral high-performance liquid chromatography
    Fadnavis, N
    Bhaskar, V
    Deshpande, A
    Bhalerao, U
    ANALYTICA CHIMICA ACTA, 2001, 441 (02) : 297 - 301
  • [24] DIRECT ENANTIOMERIC SEPARATION OF FLAVANONES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING VARIOUS CHIRAL STATIONARY PHASES
    FICARRA, P
    FICARRA, R
    BERTUCCI, C
    TOMMASINI, S
    CALABRO, ML
    COSTANTINO, D
    CARULLI, M
    PLANTA MEDICA, 1995, 61 (02) : 171 - 176
  • [25] Separation of triacylglycerol species from interesterified oils by high-performance liquid chromatography
    Lee, Jeung Hee
    Jones, Kerby C.
    Foglia, Thomas A.
    Nunez, Alberto
    Lee, Jong Ho
    Kim, Yu Mi
    Vu, Phuong-Lan
    Lee, Ki-Teak
    JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 2007, 84 (03) : 211 - 217
  • [26] On-line enantiomeric analysis using high-performance liquid chromatography in chiral, separation by simulated moving bed
    Araujo, Joao M. M.
    Rodrigues, Rui. C. R.
    Eusebio, Mario F. J.
    Mota, Jose P. B.
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1189 (1-2) : 292 - 301
  • [27] CHIRAL COVALENTLY BONDED STATIONARY PHASES FOR THE SEPARATION OF ENANTIOMERIC AMINE DERIVATIVES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    DAPPEN, R
    MEYER, VR
    ARM, H
    JOURNAL OF CHROMATOGRAPHY, 1984, 295 (02): : 367 - 376
  • [28] ENANTIOMERIC SEPARATION OF TETRAHYDROISOQUINOLINE ALKALOIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH BETA-CYCLODEXTRIN AS CHIRAL SELECTOR
    STAMMEL, W
    WOESLE, B
    THOMAS, H
    CHIRALITY, 1995, 7 (01) : 10 - 19
  • [29] ENANTIOMERIC SEPARATION OF BETA-BLOCKERS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    TRAN, CD
    DOTLICH, M
    JOURNAL OF CHEMICAL EDUCATION, 1995, 72 (01) : 71 - 73
  • [30] ENANTIOMERIC SEPARATION OF RACEMIC THIOSULPHINATE ESTERS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    BAUER, R
    BREU, W
    WAGNER, H
    WEIGAND, W
    JOURNAL OF CHROMATOGRAPHY, 1991, 541 (1-2): : 464 - 468