Initial performance evaluation of the UniCel® DxH 800 Coulter® cellular analysis system

被引:26
作者
Hedley, B. D. [1 ]
Keeney, M. [1 ]
Chin-Yee, I. [1 ]
Brown, W. [1 ]
机构
[1] London Hlth Sci Ctr, Dept Hematol, London, ON N6A 5W9, Canada
关键词
Hematology analyzer; WBC; NRBC; platelet count; extreme leukocytosis; interference; PLATELET TRANSFUSION; HIGH-RISK; CHEMOTHERAPY; LEUKEMIA; COMPLICATIONS; NEUTROPENIA; THRESHOLDS; ANALYZERS; MORTALITY; THERAPY;
D O I
10.1111/j.1751-553X.2010.01239.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
P>The Beckman Coulter UniCel (R) DxH 800 is a hematology analyzer incorporating new electronic and mechanical design with advanced algorithm technology to perform CBC, white blood cell (WBC) differential, nucleated red blood cell (NRBC), and reticulocyte analysis. Evaluation of this instrument was performed in our 800-bed tertiary care hospital and specifically centered upon the correlation of WBC, NRBC, and platelet (PLT) enumeration when compared to a predicate analyzer, the Coulter (R) LH 780, and flow cytometry (FCM) reference methods. Of particular interest were those samples with morphologically confirmed interference and extreme leukocytosis (evaluated with respect to red blood cell parameter correction). The sample set (n = 272) consisted of morphologically normal and hematologically abnormal patients. Correlation of the WBC, PLT, and NRBC showed r2 values of 0.994, 0.985, and 0.910 for the DxH 800 vs. FCM, respectively. The presence of interfering particles did not affect the accuracy of the DxH 800 with respect to WBC counts. The DxH 800 showed accurate PLT and NRBC counts in the clinically significant low range when compared to FCM. Compared to the LH 780, flagging rates were significantly reduced (NRBC flag), or equivalent (WBC, PLT flag) on the DxH 800. The DxH 800 demonstrated higher sensitivity and specificity for PLTs and NRBCs and achieved a lower NRBC false negative rate compared to the LH 780. The UniCel (R) DxH 800 represents a significant improvement to previous impedance analyzers in accurately detecting the presence of NRBCs at counts > 1/100 WBC. Furthermore, it provides accurate PLT and WBC counts in the presence of interference and improved NRBC flagging efficiency when compared to the LH 780. Correction of red blood cell parameters is appropriate and accurate in cases of extreme leukocytosis.
引用
收藏
页码:45 / 56
页数:12
相关论文
共 32 条
[1]  
Aulesa C, 2004, Lab Hematol, V10, P14, DOI 10.1532/LH96.03030
[2]  
Aulesa C, 2003, Lab Hematol, V9, P15
[3]   Fever and neutropenia: the early years [J].
Bodey, Gerald P. .
JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 2009, 63 :I3-I13
[4]  
Bourner G, 2005, Lab Hematol, V11, P285, DOI 10.1532/LH96.05036
[5]  
Brown W., 2001, LAB HEMATOL, V7, P229
[6]  
Chin-yee I., 2002, LAB HEMATOLOGY, V8, P210
[7]   Effect of outpatient treatment of febrile neutropenia on the risk threshold for the use of CSF in patients with cancer treated with chemotherapy [J].
Cosler, LE ;
Sivasubramaniam, V ;
Agboola, O ;
Crawford, J ;
Dale, D ;
Lyman, GH .
VALUE IN HEALTH, 2005, 8 (01) :47-52
[8]   Identifying patients at high risk for neutropenic complications during chemotherapy for metastatic breast cancer with doxorubicin or pegylated liposomal doxorubicin - The development of a prediction model [J].
Dranitsaris, George ;
Rayson, Daniel ;
Vincent, Mark ;
Chang, Jose ;
Gelmon, Karen ;
Sandor, David ;
Reardon, Greg .
AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2008, 31 (04) :369-374
[9]  
ENGLAND JM, 1994, CLIN LAB HAEMATOL, V16, P157
[10]  
Fernandez T., 2001, Laboratory Hematology, V7, P217