Optimal passage size for solar collector microchannel and tube-on-plate absorbers

被引:30
作者
Moss, R. W. [1 ]
Shire, G. S. F. [1 ]
Henshall, P. [2 ]
Eames, P. C. [3 ]
Arya, F. [4 ]
Hyde, T. [4 ]
机构
[1] Univ Warwick, Sch Engn, Coventry, W Midlands, England
[2] Loughborough Univ Technol, Sci & Technol Facil Council, Ctr Renewable Energy Syst Technol, Loughborough, Leics, England
[3] Loughborough Univ Technol, Ctr Renewable Energy Syst Technol, Loughborough, Leics, England
[4] Univ Ulster, Sch Built Environm, Coleraine, Londonderry, North Ireland
基金
英国工程与自然科学研究理事会;
关键词
Solar collector; Solar absorber; Single pass; Double pass; Thermal; Flat panel; Heat transfer; Laminar; Turbulent; Microchannel; Serpentine; Pressure drop; Pumping power; Optimisation; WATER-HEATING SYSTEM; AIR HEATERS; THERMAL PERFORMANCE; MICRO-CHANNELS; PARALLEL-FLOW; OPTIMIZATION; DESIGN;
D O I
10.1016/j.solener.2017.05.030
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Solar thermal collectors for buildings use a heat transfer fluid passing through heat exchange channels in the absorber. Flat plate absorbers may pass the fluid through a tube bonded to a thermally conducting plate or achieve lower thermal resistance and pressure drop by using a flooded panel or microchannel design. The pressure drop should be low to minimise power input to the circulating pump. A method is presented for choosing the optimum channel hydraulic diameter subject to geometric similarity and pumping power constraints; this is an important preliminary design choice for any solar collector designer. The choice of pumping power is also illustrated in terms of relative energy source costs. Both microchannel and serpentine tube systems have an optimum passage diameter, albeit for different reasons. Double-pass and flooded panel designs are considered as special microchannel cases. To maintain efficiency, the pumping power per unit area must rise as the passage length increases. Beyond the optimum pumping power the rise in operating cost outweighs the increase in collector efficiency. (C) 2017 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.orgflicensesiby/4.0/).
引用
收藏
页码:718 / 731
页数:14
相关论文
共 47 条
[1]   HEAT REMOVAL FACTOR FOR A FLAT-PLATE SOLAR COLLECTOR WITH A SERPENTINE TUBE [J].
ABDELKHALIK, SI .
SOLAR ENERGY, 1976, 18 (01) :59-64
[2]   Energy and exergy analysis of hybrid micro-channel photovoltaic thermal module [J].
Agrawal, Sanjay ;
Tiwari, G. N. .
SOLAR ENERGY, 2011, 85 (02) :356-370
[3]   HEAT REMOVAL FACTOR FOR A SERPENTINE ABSORBER PLATE [J].
AKGUN, MA .
SOLAR ENERGY, 1988, 41 (01) :109-111
[4]   Analytical and Experimental Investigation to Determine the Variation of Hottel-Whillier-Bliss Constants for a Scaled Forced Circulation Flat-Plate Solar Water Heater [J].
Arunachala, U. C. ;
Bhatt, M. Siddhartha ;
Sreepathi, L. K. .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2015, 137 (05)
[5]   Optimization of solar thermal fraction in PVT systems [J].
Aste, Niccolo ;
Del Pero, Claudio ;
Leonforte, Fabrizio .
1ST INTERNATIONAL CONFERENCE ON SOLAR HEATING AND COOLING FOR BUILDINGS AND INDUSTRY (SHC 2012), 2012, 30 :8-18
[6]   Optimal aspect ratios for non-isothermal flat plate solar collectors for air heating [J].
Bracamonte, Johane ;
Baritto, Miguel .
SOLAR ENERGY, 2013, 97 :605-613
[7]  
Caffell A., 1998, US patent, Patent No. [5,769,069, 5769069]
[8]   A coupled numerical model for tube-on-sheet flat-plate solar liquid collectors. Analysis and validation of the heat transfer mechanisms [J].
Ceron, J. F. ;
Perez-Garcia, J. ;
Solano, J. P. ;
Garcia, A. ;
Herrero-Martin, R. .
APPLIED ENERGY, 2015, 140 :275-287
[9]   A review of the performance of double pass solar air heater [J].
Chamoli, Sunil ;
Chauhan, Ranchan ;
Thakur, N. S. ;
Saini, J. S. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2012, 16 (01) :481-492
[10]   Frictional performance of U-type wavy tubes [J].
Chen, IY ;
Lai, YK ;
Wang, CC .
JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2003, 125 (05) :880-886