Effects of low-level inhalation exposure to carbon dioxide in indoor environments: A short review on human health and psychomotor performance

被引:249
作者
Azuma, Kenichi [1 ,4 ]
Kagi, Naoki [2 ,4 ]
Yanagi, U. [3 ,4 ]
Osawa, Haruki [4 ]
机构
[1] Kindai Univ, Fac Med, Dept Environm Med & Behav Sci, 377-2 Ohnohigashi, Osakasayama, Osaka 5898511, Japan
[2] Tokyo Inst Technol, Grad Sch Informat Sci & Engn, Dept Mech & Environm Informat, Tokyo 1528550, Japan
[3] Kogakuin Univ, Sch Architecture, Dept Architecture, Tokyo 1638677, Japan
[4] Natl Inst Publ Hlth, Dept Environm Hlth, Wako, Saitama 3510197, Japan
关键词
Carbon dioxide; Indoor air; Low-level exposure; Physiological change; Psychomotor performance; SICK BUILDING SYNDROME; DAY-CARE-CENTERS; CO2; CONCENTRATIONS; AIR-QUALITY; OFFICE BUILDINGS; VENTILATION RATE; DECISION-MAKING; SYMPTOMS; RESPONSES; WORKERS;
D O I
10.1016/j.envint.2018.08.059
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Scientific literature and documents pertaining to the effects of inhalation exposure to carbon dioxide (CO2) on human health and psychomotor performance were reviewed. Linear physiological changes in circulatory, cardiovascular, and autonomic systems on exposure to CO2 at concentrations ranging from 500 to 5000 ppm were evident. Human experimental studies have suggested that short-term CO2 exposure beginning at 1000 ppm affects cognitive performances including decision making and problem resolution. Changes in autonomic systems due to low-level exposure to CO2 may involve these effects. Further research on the long-term effects of low-level CO2 exposure on the autonomic system is required. Numerous epidemiological studies indicate an association between low-level exposure to CO2 beginning at 700 ppm and building-related symptoms. Respiratory symptoms have been indicated in children exposed to indoor CO2 concentrations higher than 1000 ppm. However, other indoor comorbid pollutants are possibly involved in such effects. In the context of significant linear increase of globally ambient CO2 concentration caused by anthropogenic activities and sources, reducing indoor CO2 levels by ventilation with ambient air represents an increase in energy consumption in an air-conditioned building. For the efficient energy control of CO2 intruding a building from ambient air, the rise of atmospheric CO2 concentration needs to be urgently suppressed.
引用
收藏
页码:51 / 56
页数:6
相关论文
共 61 条
[1]  
ACGIH, 2017, AM C GOVT IND HYGIEN
[2]  
ALBERTS WM, 1994, J ALLERGY CLIN IMMUN, V94, P289, DOI 10.1053/ai.1994.v94.a56007
[3]   Airplane pilot flight performance on 21 maneuvers in a flight simulator under varying carbon dioxide concentrations [J].
Allen, Joseph G. ;
MacNaughton, Piers ;
Cedeno-Laurent, Jose Guillermo ;
Cao, Xiaodong ;
Flanigan, Skye ;
Vallarino, Jose ;
Rueda, Francisco ;
Donnelly-McLay, Deborah ;
Spengler, John D. .
JOURNAL OF EXPOSURE SCIENCE AND ENVIRONMENTAL EPIDEMIOLOGY, 2019, 29 (04) :457-468
[4]   Associations of Cognitive Function Scores with Carbon Dioxide, Ventilation, and Volatile Organic Compound Exposures in Office Workers: A Controlled Exposure Study of Green and Conventional Office Environments [J].
Allen, Joseph G. ;
MacNaughton, Piers ;
Satish, Usha ;
Santanam, Suresh ;
Vallarino, Jose ;
Spengler, John D. .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2016, 124 (06) :805-812
[5]  
[Anonymous], P 8 INT C IND AIR QU
[6]  
[Anonymous], IND POLL
[7]  
[Anonymous], 2013, Contribution of working group i to the fifth assessment report of the intergovernmental panel on climate change
[8]  
[Anonymous], 2016, WMO B
[9]   Associations between indoor CO2 concentrations and sick building syndrome symptoms in US office buildings:: An analysis of the 1994-1996 BASE study data [J].
Apte, MG ;
Fisk, WJ ;
Daisey, JM .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 2000, 10 (04) :246-257
[10]   Carbon dioxide transport [J].
Arthurs, G. J. ;
Sudhakar, M. .
BJA EDUCATION, 2005, 5 (06) :207-210