Mouthguard biosensor with telemetry system for monitoring of saliva glucose: A novel cavitas sensor

被引:249
作者
Arakawa, Takahiro [1 ]
Kuroki, Yusuke [1 ]
Nitta, Hiroki [1 ]
Chouhan, Prem [2 ]
Toma, Koji [1 ]
Sawada, Shin-ichi [3 ]
Takeuchi, Shuhei [4 ]
Sekita, Toshiaki [4 ]
Akiyoshi, Kazunari [3 ]
Minakuchi, Shunsuke [4 ]
Mitsubayashi, Kohji [1 ]
机构
[1] Tokyo Med & Dent Univ, Inst Biomat & Bioengn, Dept Biomed Devices & Instrumentat, Chiyoda Ku, 2-3-10 Kanda Surugadai, Tokyo 1010062, Japan
[2] Univ London Imperial Coll Sci Technol & Med, Fac Med, South Kensington Campus, London SW7 2AZ, England
[3] Kyoto Univ, Grad Sch Engn, Dept Polymer Chem, Nishikyo Ku, Kyoto 6158510, Japan
[4] Tokyo Med & Dent Univ, Gerodontol & Oral Rehabil, Bunkyo Ku, 1-5-45 Yushima, Tokyo 1138549, Japan
基金
日本科学技术振兴机构; 日本学术振兴会;
关键词
Mouthguard; Biosensor; Glucose; Oral cavity; Saliva glucose; Glucose oxidase;
D O I
10.1016/j.bios.2015.12.014
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We develop detachable "Cavitas sensors" to apply to the human oral cavity for non-invasive monitoring of saliva glucose. A salivary biosensor incorporating Pt and Ag/AgCl electrodes on a mouthguard support with an enzyme membrane is developed and tested. Electrodes are formed on the polyethylene terephthalate glycol (PETG) surface of the mouthguard. The Pt working electrode is coated with a glucose oxidase (GOD) membrane. The biosensor seamlessly is integrated with a glucose sensor and a wireless measurement system. When investigating in-vitro performance, the biosensor exhibits a robust relationship between output current and glucose concentration. In artificial saliva composed of salts and proteins, the glucose sensor is capable of highly sensitive detection over a range of 5-1000 mu mol/L of glucose, which encompasses the range of glucose concentrations found in human saliva. We demonstrate the ability of the sensor and wireless communication module to monitor saliva glucose in a phantom jaw imitating the structure of the human oral cavity. Stable and long-term real-time monitoring (exceeding 5 h) with the telemetry system is achieved. The mouthguard biosensor will be useful as a novel method for real-time non-invasive saliva glucose monitoring for better management of dental patients. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:106 / 111
页数:6
相关论文
共 25 条
[1]   Glucose estimation in the salivary secretion of diabetes mellitus patients [J].
Abikshyeet, Panda ;
Ramesh, Venkatapathy ;
Oza, Nirima .
DIABETES METABOLIC SYNDROME AND OBESITY-TARGETS AND THERAPY, 2012, 5 :149-154
[2]  
Aguirre F., 2013, IDF DIABETES ATLAS
[3]   Multiparameter techniques for non-invasive measurement of blood glucose [J].
Amaral, Carlos F. ;
Brischwein, Martin ;
Wolf, Bernhard .
SENSORS AND ACTUATORS B-CHEMICAL, 2009, 140 (01) :12-16
[4]  
[Anonymous], IDF DIABETES ATLAS
[5]   Soft contact lens biosensor for in situ monitoring of tear glucose as non-invasive blood sugar assessment [J].
Chu, Ming Xing ;
Miyajima, Kumiko ;
Takahashi, Daishi ;
Arakawa, Takahiro ;
Sano, Kenji ;
Sawada, Shin-ichi ;
Kudo, Hiroyuki ;
Iwasaki, Yasuhiko ;
Akiyoshi, Kazunari ;
Mochizuki, Manabu ;
Mitsubayashi, Kohji .
TALANTA, 2011, 83 (03) :960-965
[6]   Biomedical soft contact-lens sensor for in situ ocular biomonitoring of tear contents [J].
Chu, MingXing ;
Shirai, Takayuki ;
Takahashi, Daishi ;
Arakawa, Takahiro ;
Kudo, Hiroyuki ;
Sano, Kenji ;
Sawada, Shin-ichi ;
Yano, Kazuyoshi ;
Iwasaki, Yasuhiko ;
Akiyoshi, Kazunari ;
Mochizuki, Manabu ;
Mitsubayashi, Kohji .
BIOMEDICAL MICRODEVICES, 2011, 13 (04) :603-611
[7]   Current development in non-invasive glucose monitoring [J].
do Amaral, Carlos Eduardo Ferrante ;
Wolf, Benhard .
MEDICAL ENGINEERING & PHYSICS, 2008, 30 (05) :541-549
[8]   CORROSION OF GOLD AND AMALGAM PLACED IN CONTACT WITH EACH OTHER [J].
FUSAYAMA, T ;
NOMOTO, S ;
KATAYORI, T .
JOURNAL OF DENTAL RESEARCH, 1963, 42 (05) :1183-&
[9]   Self-monitoring of blood glucose [J].
Garg, S. ;
Hirsch, I. B. ;
Bode, B. W. ;
Battelino, T. ;
Pickup, J. ;
Dassau, E. ;
Atlas, E. ;
Phillip, M. ;
Danne, T. ;
Bolinder, J. ;
Heinemann, L. ;
Kaufman, N. ;
Hod, M. ;
Jovanovic, L. ;
Spector, D. ;
Shikora, S. ;
Skyler, J. S. ;
Zisser, H. ;
Riddell, M. C. .
INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2010, 64 :1-69
[10]   Wearable salivary uric acid mouthguard biosensor with integrated wireless electronics [J].
Kim, Jayoung ;
Imani, Somayeh ;
de Araujo, William R. ;
Warchall, Julian ;
Valdes-Ramirez, Gabriela ;
Paixao, Thiago R. L. C. ;
Mercier, Patrick P. ;
Wang, Joseph .
BIOSENSORS & BIOELECTRONICS, 2015, 74 :1061-1068