Comparison between evaporative light scattering detection and charged aerosol detection for the analysis of saikosaponins

被引:83
作者
Eom, Han Young [1 ]
Park, So-Young [2 ]
Kim, Min Kyung [1 ]
Suh, Joon Hyuk [1 ]
Yeom, Hyesun [1 ]
Min, Jung Won [1 ]
Kim, Unyong [1 ]
Lee, Jeongmi [3 ]
Youm, Jeong-Rok [1 ]
Han, Sang Beom [1 ]
机构
[1] Chung Ang Univ, Coll Pharm, Dept Pharmaceut Anal, Seoul 156756, South Korea
[2] Dankook Univ, Coll Adv Sci, Dept Nanobiomed Sci, Cheonan 330714, Chungnam, South Korea
[3] Sungkyunkwan Univ, Coll Pharm, Suwon 440746, Gyeonggi, South Korea
关键词
Charged aerosol detection (CAD); Evaporative light scattering detection (ELSD); Saikosaponins; Bupleuri Radix; SUPERCRITICAL-FLUID CHROMATOGRAPHY; PERFORMANCE LIQUID-CHROMATOGRAPHY; BUPLEURUM-FALCATUM; PHARMACEUTICAL ANALYSIS; MASS-SPECTROMETRY; RADIX-BUPLEURI; ESI-MS; HPLC; SAPONINS; TANG;
D O I
10.1016/j.chroma.2010.04.047
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Saikosaponins are triterpene saponins derived from the roots of Bupleurum falcatum L. (Umbelliferae), which has been traditionally used to treat fever, inflammation, liver diseases, and nephritis. It is difficult to analyze saikosaponins using HPLC-UV due to the lack of chromophores. Therefore, evaporative light scattering detection (ELSD) is used as a valuable alternative to UV detection. More recently, a charged aerosol detection (CAD) method has been developed to improve the sensitivity and reproducibility of ELSD. In this study, we compared CAD and ELSD methods in the simultaneous analysis of 10 saikosaponins, including saikosaponins-A, -B-1, -B-2, -B-3, -B-4, -C, -D, -G, -H and -I. A mixture of the 10 saikosaponins was injected into the Ascentis (R) Express C18 column (100 mm x 4.6 mm, 2.7 mu m) with gradient elution and detection with CAD and ELSD by splitting. We examined various factors that could affect the sensitivity of the detectors including various concentrations of additives, pH and flow rate of the mobile phase, purity of nitrogen gas and the CAD range. The sensitivity was determined based on the signal-to-noise ratio. The best sensitivity for CAD was achieved with 0.1 mM ammonium acetate at pH 4.0 in the mobile phase with a flow rate of 1.0 mL/min, and the CAD range at 100 pA, whereas that for ELSD was achieved with 0.01% acetic acid in the mobile phase with a flow rate at 0.8 mL/min. The purity of the nitrogen gas had only minor effects on the sensitivities of both detectors. Finally, the sensitivity for CAD was two to six times better than that of ELSD. Taken together, these results suggest that CAD provides a more sensitive analysis of the 10 saikosaponins than does ELSD. (c) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:4347 / 4354
页数:8
相关论文
共 37 条
  • [1] Determination of saikosaponin derivatives in Radix bupleuri and in pharmaceuticals of the Chinese multiherb remedy Xiaochaihu-tang using liquid chromatographic tandem mass spectrometry
    Bao, YW
    Li, CA
    Shen, HW
    Nan, FJ
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (14) : 4208 - 4216
  • [2] In vivo and in vitro antiinflammatory activity of saikosaponins
    Benito, PB
    Martínez, MJA
    Sen, AMS
    Gómez, AS
    Matellano, LF
    Contreras, SS
    Lanza, AMD
    [J]. LIFE SCIENCES, 1998, 63 (13) : 1147 - 1156
  • [3] Analysis of the molecular size distribution of polyethylene glycols by CE-UV versus HPLC with evaporative light scattering detection
    Brinz, Daniela
    Holzgrabe, Ulrike
    [J]. ELECTROPHORESIS, 2008, 29 (17) : 3605 - 3611
  • [4] Corona-charged aerosol detection in supercritical fluid chromatography for pharmaceutical analysis
    Brunelli, C.
    Gorecki, T.
    Zhao, Y.
    Sandra, P.
    [J]. ANALYTICAL CHEMISTRY, 2007, 79 (06) : 2472 - 2482
  • [5] Sho-saiko-to (Xiao-Chai-Hu-Tang) and crude saikosaponins inhibit hepatitis B virus in a stable HBV-producing cell line
    Chang, Jung-San
    Wang, Kuo-Chih
    Liu, Hong-Wen
    Chen, Mei-Chun
    Chiang, Lien-Chai
    Lin, Chun-Ching
    [J]. AMERICAN JOURNAL OF CHINESE MEDICINE, 2007, 35 (02): : 341 - 351
  • [6] Effects of Bupleurum scorzoneraefolium, Bupleurum falcatum, and saponins on nephrotoxic serum nephritis in mice
    Chen, S. -M.
    Sato, N.
    Yoshida, M.
    Satoh, N.
    Ueda, S.
    [J]. JOURNAL OF ETHNOPHARMACOLOGY, 2008, 116 (03) : 397 - 402
  • [7] Simultaneous quantitation of tobramycin and colistin sulphate by HPLC with evaporative light scattering detection
    Clarot, I.
    Storme-Paris, I.
    Chaminade, P.
    Estevenon, O.
    Nicolas, A.
    Rieutord, A.
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 50 (01) : 64 - 67
  • [8] Development and testing of a detection method for liquid chromatography based on aerosol charging
    Dixon, RW
    Peterson, DS
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (13) : 2930 - 2937
  • [9] Saponins from the root of Bupleurum falcatum
    Ebata, N
    Nakajima, K
    Hayashi, K
    Okada, M
    Maruno, M
    [J]. PHYTOCHEMISTRY, 1996, 41 (03) : 895 - 901
  • [10] Evaporative light scattering detection (ELSD) for the analysis of natural products
    Ganzera, Markus
    Stuppner, Hermann
    [J]. CURRENT PHARMACEUTICAL ANALYSIS, 2005, 1 (02) : 135 - 144