Anodic stripping voltammetric determination of lead in tap water at an ordered mesoporous carbon/Nafion composite film electrode

被引:82
作者
Zhu, Liande [1 ]
Tian, Chunyuan [1 ]
Yang, Ruilan [1 ]
Zhai, Jiangli [1 ]
机构
[1] NE Normal Univ, Sch Chem, Changchun 130024, Jilin, Peoples R China
关键词
ordered mesoporous carbon; lead; anodic stripping voltammetry; Nafion;
D O I
10.1002/elan.200704088
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive mercury-free lead (Pb2+) sensor has been proposed based on an ordered mesoporous carbon and Nafion composite film (OMC/Nafion) coated glassy carbon electrode. The analysis of Ph2+ using anodic stripping voltammetry (ASV) includes two steps. Pb2+ ions are firstly reduced and deposited on the electrode surface in a Ph2+ solution (10 mL) during a preconcentration step biased at -1.0 V, followed by a measurement step by differential pulse voltammetry (DPV) within the potential range of -0.8 to -0.3 V (scan rate: 20 mV/s, frequency: 20 Hz, amplitude: 50 mV, pulse width: 50 ms). Linear calibration curve was found to be from 20 nM to 2 mu M for Pb2+ with a sensitivity of 17.4 +/- 1.38 mu A/mu M after a 5-min of preconcentration. The detection limit was estimated to be around 4.60 +/- 0.12 nM at the signal to noise ratio of 3. Reproducibility (RSD%) was found to be 3.0% for a single sensor with eight measurements and 4.3% for five sensors prepared with identical procedures. The practical application of the proposed lead sensor was verified by determination of trace level of Pb2+ in tap water sample.
引用
收藏
页码:527 / 533
页数:7
相关论文
共 31 条
[1]   STUDIES ON THE ANODIC-STRIPPING VOLTAMMETRY OF LEAD IN POLLUTED ESTUARINE WATERS [J].
ACEBAL, SA ;
REBELLO, AD .
ANALYTICA CHIMICA ACTA, 1983, 148 (APR) :71-78
[2]  
[Anonymous], 1976, MARINE POLLUTION
[3]   ANION INDUCED ADSORPTION OF CADMIUM(2) ON MERCURY FROM IODIDE AND BROMIDE MEDIA [J].
ANSON, FC ;
BARCLAY, DJ .
ANALYTICAL CHEMISTRY, 1968, 40 (12) :1791-&
[4]  
BARCLAY DJ, 1970, J ELECTROANAL CHEM, V28, P71, DOI 10.1016/0368-1874(70)80127-7
[5]   INSITU ELECTRODEPOSITION FOR THE DETERMINATION OF LEAD AND CADMIUM IN SEA-WATER [J].
BATLEY, GE .
ANALYTICA CHIMICA ACTA, 1981, 124 (01) :121-129
[6]   Determination of heavy metals in wines by anodic stripping voltammetry with thick-film modified electrode [J].
Brainina, KZ ;
Stozhko, NY ;
Belysheva, GM ;
Inzhevatova, OV ;
Kolyadina, LI ;
Cremisini, C ;
Galletti, M .
ANALYTICA CHIMICA ACTA, 2004, 514 (02) :227-234
[7]   Anodic stripping voltammetry of trace metals by batch injection analysis [J].
Brett, CMA ;
Brett, AMO ;
Tugulea, L .
ANALYTICA CHIMICA ACTA, 1996, 322 (03) :151-157
[8]   STRIPPING ANALYSIS AT MERCURY MICROELECTRODES IN THE ABSENCE OF SUPPORTING ELECTROLYTE [J].
DANIELE, S ;
MAZZOCCHIN, GA .
ANALYTICA CHIMICA ACTA, 1993, 273 (1-2) :3-11
[9]   Detection of trace levels of Pb2+ in tap water at boron-doped diamond electrodes with anodic stripping voltammetry [J].
Dragoe, D ;
Spataru, N ;
Kawasaki, R ;
Manivannan, A ;
Spataru, T ;
Tryk, DA ;
Fujishima, A .
ELECTROCHIMICA ACTA, 2006, 51 (12) :2437-2441
[10]   Direct electron transfer and electrocatalysis of hemoglobin adsorbed on mesoporous carbon through layer-by-layer assembly [J].
Feng, Jiu-Ju ;
Xu, Jing-Juan ;
Chen, Hong-Yuan .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (08) :1618-1624