Value of contrast-enhanced ultrasonography for detecting renal infarcts proven by contrast enhanced CT. A feasibility study

被引:57
作者
Bertolotto, Michele [1 ]
Martegani, Alberto [2 ]
Aiani, Luca [2 ]
Zappetti, Roberta [1 ]
Cernic, Stefano [1 ]
Cova, Maria Assunta [1 ]
机构
[1] Univ Trieste, Osped Cattinara, UCO Radiol, I-34149 Trieste, Italy
[2] Osped Valduce, Serv Diagnost Immagini, I-22100 Como, Italy
关键词
microbubble contrast agents; ultrasound; kidney; renal infarction; contrast-enhanced ultrasonography;
D O I
10.1007/s00330-007-0747-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The effectiveness of contrast-enhanced ultrasonography (CEUS) in the evaluation of patients with acute renal infarcts was investigated, using contrast-enhanced helical computed tomography (CT) as the reference imaging procedure. Twenty-seven consecutive patients with acute renal infarcts detected with contrast-enhanced helical CT underwent CEUS. Digital cine-clips of CEUS were evaluated by two independent readers blinded to CT findings. Image quality was rated subjectively on a four-point scale. Then, readers were asked to assign a confidence level in diagnosis of renal infarct at the upper pole, medium portion, and lower pole of each kidney according to a five-degree scale, ranging from definitely absent to definitely present. ROC curve analysis was employed to assess the overall confidence of diagnosis of infarct, and weighted kappa values were calculated to assess inter-reader agreement. The subjective image quality of CEUS was lower than the image quality of CT at the upper poles. However, the diagnostic performance of CEUS was excellent (area under receiver-operator characteristic curve 0.992 +/- 0.006 for reader 1; 0.991 +/- 0.007 for reader 2), with very good inter-reader agreement (weighted kappa value=0.83). CEUS is a reproducible tool to detect acute renal infarcts in men, with a diagnostic performance approaching that of CT.
引用
收藏
页码:376 / 383
页数:8
相关论文
共 25 条
[11]   Interlobular vasculature in renal transplants: A power Doppler US study with MR correlation [J].
Martinoli, C ;
Crespi, G ;
Bertolotto, M ;
Rollandi, G ;
Rosenberg, I ;
Pretolesi, F ;
Derchi, LE .
RADIOLOGY, 1996, 200 (01) :111-117
[12]  
Murphy SW, 2000, J AM SOC NEPHROL, V11, P177, DOI 10.1681/ASN.V111177
[13]   Contrast-enhanced ultrasound of the kidneys [J].
Nilsson, A .
EUROPEAN RADIOLOGY, 2004, 14 :P104-P109
[14]  
Nilsson A, 1997, J ULTRAS MED, V16, P275
[15]   Receiver operating characteristic curves and their use in radiology [J].
Obuchowski, NA .
RADIOLOGY, 2003, 229 (01) :3-8
[16]   The safety of Sonovue® in abdominal applications:: Retrospective analysis of 23188 investigations [J].
Piscaglia, Fabio ;
Bolondi, Luigi .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2006, 32 (09) :1369-1375
[17]   Detection of focal renal perfusion defects in rabbits after sulphur hexafluoride-filled microbubble injection at low transmission power ultrasound insonation [J].
Quaia, E ;
Siracusano, S ;
Palumbo, A ;
Ciciliato, S ;
Rossi, S ;
Bruni, S ;
Bussani, R ;
Cova, M .
EUROPEAN RADIOLOGY, 2006, 16 (01) :166-172
[18]   Renal parenchymal diseases: Is characterization feasible with ultrasound? [J].
Quaia, E ;
Bertolotto, M .
EUROPEAN RADIOLOGY, 2002, 12 (08) :2006-2020
[19]   Renal imaging with ultrasound contrast: current status [J].
Robbin, ML ;
Lockhart, ME ;
Barr, RG .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2003, 41 (05) :963-+
[20]   Renal cortical perfusion in rabbits: Visualization with color amplitude imaging and an experimental microbubble-based US contrast agent [J].
Taylor, GA ;
Ecklund, K ;
Dunning, PS .
RADIOLOGY, 1996, 201 (01) :125-129