The effect of whole-body vibration on peri-implant bone healing in rats

被引:39
作者
Ogawa, Toru [2 ]
Zhang, Xiaolei
Naert, Ignace
Vermaelen, Peter [3 ,4 ]
Deroose, Christophe M. [3 ,4 ]
Sasaki, Keiichi [2 ]
Duyck, Joke [1 ]
机构
[1] Katholieke Univ Leuven, Dept Prosthet Dent, Sch Dent Oral Pathol & Maxillofacial Surg, BIOMAT Res Cluster,Fac Med, B-3000 Louvain, Belgium
[2] Tohoku Univ, Grad Sch Dent, Div Adv Prosthet Dent, Sendai, Miyagi 980, Japan
[3] Katholieke Univ Leuven, Div Nucl Med, B-3000 Louvain, Belgium
[4] Katholieke Univ Leuven, Mol Small Anim Imaging Ctr MoSAIC, B-3000 Louvain, Belgium
关键词
low-magnitude and high-frequency loading; oral implant; peri-implant bone; positron emission tomography (PET); rat tibia; whole-body vibration; FREQUENCY MECHANICAL STIMULI; MARROW STROMAL CELLS; LOW-MAGNITUDE; DENTAL IMPLANTS; LOW-AMPLITUDE; F-18-FLUORIDE; IMMEDIATE; SIGNALS; STRAIN; DIFFERENTIATION;
D O I
10.1111/j.1600-0501.2010.02020.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose The aim of this study was to evaluate the effect of low-magnitude, high-frequency (LMHF) loading, applied by means of whole-body vibration (WBV), on peri-implant bone healing and implant osseointegration in rat tibiae. Materials and methods A custom-made titanium implant was inserted into the proximal metaphysis of the tibiae of 42 rats and left to heal for 3, 7, 14 or 25 days. Half of the animals received LMHF mechanical vibration for 5 days per week (test), whereas the others served as unloaded controls. The WBV consisted of 15 consecutive frequency steps (12, 20, 30, ... to 150 Hz). Each of the 15 frequencies was applied for 2000 cycles, at an acceleration of 0.3 g. In the group with a 25-day healing period, PET images were taken at -1 (day before surgery), 3, 5, 7, 10, 14 and 21 days of loading, after an injection of [18F]sodium fluoride, a positron-emitting tracer. The ratio of the metabolic activity around the implants to that of a reference site (uptake ratio) was calculated as a measure of bone metabolism. Bone-to-implant contact (BIC) and peri-implant bone fraction (BF) were analysed for histomorphometrical measurement. Results The mean BIC and BF were significantly influenced by both the loading and the healing time (ANOVA, P < 0.01). The PET images did not reveal any significant difference in uptake ratio between the test and the control implants. Conclusion LMHF loading increased BIC and BF significantly. The results confirm the bone-stimulating potential of LMHF loading, through WBV, on peri-implant bone healing and osseointegration. To cite this article:Ogawa T, Zhang X, Naert I, Vermaelen P. Deroose CM, Sasaki K, Duyck J. The effect of whole-body vibration on peri-implant bone healing in rats.Clin. Oral Impl. Res. 22, 2011; 302-307.doi: 10.1111/j.1600-0501.2010.02020.x.
引用
收藏
页码:302 / 307
页数:6
相关论文
共 50 条
  • [1] Influence of whole-body vibration time on peri-implant bone healing: a histomorphometrical animal study
    Ogawa, Toru
    Possemiers, Tine
    Zhang, Xiaolei
    Naert, Ignace
    Chaudhari, Amol
    Sasaki, Keiichi
    Duyck, Joke
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2011, 38 (02) : 180 - 185
  • [2] The basic science of peri-implant bone healing
    Kuzyk, Paul R. T.
    Schemitsch, Emil H.
    INDIAN JOURNAL OF ORTHOPAEDICS, 2011, 45 (02) : 108 - 115
  • [3] Effects of whole-body vibration on bone properties in aged rats
    Minematsu, Akira
    Nishii, Yasue
    Sakata, Susumu
    JOURNAL OF MUSCULOSKELETAL & NEURONAL INTERACTIONS, 2021, 21 (02) : 287 - 297
  • [4] Effect of high-frequency loading and parathyroid hormone administration on peri-implant bone healing and osseointegration
    Shibamoto, Aya
    Ogawa, Toru
    Duyck, Joke
    Vandamme, Katleen
    Naert, Ignace
    Sasaki, Keiichi
    INTERNATIONAL JOURNAL OF ORAL SCIENCE, 2018, 10
  • [5] Effects of alendronate on the peri-implant bone in rats
    Oh, K. C.
    Moon, H. S.
    Lee, J. H.
    Park, Y. B.
    Kim, J-H
    ORAL DISEASES, 2015, 21 (02) : 248 - 256
  • [6] Distinct Frequency Dependent Effects of Whole-Body Vibration on Non-Fractured Bone and Fracture Healing in Mice
    Wehrle, Esther
    Wehner, Tim
    Heilmann, Aline
    Bindl, Ronny
    Claes, Lutz
    Jakob, Franz
    Amling, Michael
    Ignatius, Anita
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2014, 32 (08) : 1006 - 1013
  • [7] Effect of whole-body vibration on bone properties in aging mice
    Wenger, Karl H.
    Freeman, James D.
    Fulzele, Sadanand
    Immel, David M.
    Powell, Brian D.
    Molitor, Patrick
    Chao, Yuh J.
    Gao, Hong-Sheng
    Elsalanty, Mohammed
    Hamrick, Mark W.
    Isales, Carlos M.
    Yu, Jack C.
    BONE, 2010, 47 (04) : 746 - 755
  • [8] The effect of low-magnitude high-frequency loading on peri-implant bone healing and implant osseointegration in Beagle dogs
    Wang, Shuhua
    Ogawa, Toru
    Zheng, Sheng
    Miyashita, Makiko
    Tenkumo, Taichi
    Gu, Zhiyuan
    Lian, Wenhai
    Sasaki, Keiichi
    JOURNAL OF PROSTHODONTIC RESEARCH, 2018, 62 (04) : 497 - 502
  • [9] Histologic and Biomechanical Evaluation of the Effects of Implant Insertion Torque on Peri-Implant Bone Healing
    Consolo, Ugo
    Travaglini, Domenico
    Todisco, Marzio
    Trisi, Paolo
    Galli, Silvia
    JOURNAL OF CRANIOFACIAL SURGERY, 2013, 24 (03) : 860 - 865
  • [10] Influence of hyperbaric oxygen therapy on peri-implant bone healing in rats with alloxan-induced diabetes
    Dutra Oliveira, Peterson Antonio
    Soares Dutra Oliveira, Alcione Maria
    Pablos, Aletheia Buosi
    Costa, Fernando Oliveira
    Borges Silva, Gerluza Aparecida
    dos Santos, Jean Nunes
    Cury, Patricia Ramos
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2012, 39 (09) : 879 - 886