Screw trajectory affects screw cut-out risk after fixation for nondisplaced femoral neck fracture in elderly patients

被引:12
|
作者
Wu, Yueh [1 ]
Leu, Tsai-Hsueh [1 ]
Chuang, Tai-Yuan [1 ]
Ho, Wei-Pin [1 ]
Chen, Yu-Pin [1 ]
Lin, Chung-Ying [2 ]
机构
[1] Taipei Med Univ, Wan Fang Hosp, Coll Med, Dept Orthopaed Surg,Sch Med, 3,Sec 3,Xinglong Rd, Taipei 116, Taiwan
[2] Hong Kong Polytech Univ, Dept Rehabil Sci, Fac Hlth & Social Sci, Hung Hom, Hong Kong, Peoples R China
关键词
femoral neck fracture; parallel screws; screw fixation; screw trajectory; INTRACAPSULAR FRACTURES; INTERNAL-FIXATION; CANCELLOUS SCREWS; HIP SCREWS; PARALLEL; REDUCTION;
D O I
10.1177/2309499019840252
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Incidence of femoral neck fracture has risen with the aging of the population and has critical implications with regard to patient death, functional dependence, and social costs. Screw fixation using triangular configurations and calcar placement are still the preferred treatment for nondisplaced femoral neck fracture, to reduce the risk of loss of reduction and nonunion. However, this method is still controversial in terms of the effects of screw trajectory, including parallel or nonparallel configurations, on fixation of femoral neck fractures. This study aimed to compare the incidence of complications between patients who have undergone fixation with a parallel or a nonparallel screw trajectory. Methods: We retrospectively analyzed 55 patients who were older than 60 years and diagnosed with nondisplaced femoral neck fracture from March 2014 to March 2016, and who were treated with cannulated screw fixation in our institution. Patient demographics, radiographic parameters including reduction quality, screw trajectory, and complications during the follow-up period were all evaluated. Results: The overall complication rate for screw fixation in elderly patients was 23.6%, and screw cut-out was the most common complication, occurring in 14.5% of all enrolled patients. Also, we found that screw cut-out occurred in more osteoporotic patients, and all screw cut-outs were in groups treated with a nonparallel screw trajectory. However, parallel screw fixation was inclined to back out more after fracture healing and had a lower risk of postoperative screw cut-out. Conclusions: Our results suggested that fixation with nonparallel screws for nondisplaced femoral neck fracture in elderly and osteoporotic patients might interfere with shortening of the femoral neck along with fracture healing, leaving patients at risk of postoperative screw cut-out from the femoral head.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] SLIDING SCREW-PLATE FOR FIXATION OF FEMORAL-NECK FRACTURE
    NORDKILD, P
    SONNEHOLM, S
    ACTA ORTHOPAEDICA SCANDINAVICA, 1984, 55 (06): : 616 - 619
  • [22] Risk factors for cut-out after internal fixation of trochanteric fractures in elderly subjects
    Morvan, Antoine
    Boddaert, Jacques
    Cohen-Bittan, Judith
    Picard, Herve
    Pascal-Mousselard, Hugues
    Khiami, Frederic
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2018, 104 (08) : 1183 - 1187
  • [23] High incidence of “in–out–in” posterosuperior screws after cannulated screw fixation of femoral neck fractures
    Brandon J. Yuan
    Mohamad Tayseer Shamaa
    William R. Aibinder
    Joshua A. Parry
    William W. Cross
    Jonathan D. Barlow
    Stephen A. Sems
    European Journal of Orthopaedic Surgery & Traumatology, 2020, 30 : 1417 - 1420
  • [24] Primary screw perforation or subsequent screw cut-out following proximal humerus fracture fixation using locking plates: a review of causative factors and proposed solutions
    Tristan E. McMillan
    Alan J. Johnstone
    International Orthopaedics, 2018, 42 : 1935 - 1942
  • [25] Subtrochanteric fracture after cannulated screw fixation of femoral neck fractures: A report of four cases
    Kloen, P
    Rubel, IF
    Lyden, JP
    Helfet, DL
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2003, 17 (03) : 225 - 229
  • [26] Primary screw perforation or subsequent screw cut-out following proximal humerus fracture fixation using locking plates: a review of causative factors and proposed solutions
    McMillan, Tristan E.
    Johnstone, Alan J.
    INTERNATIONAL ORTHOPAEDICS, 2018, 42 (08) : 1935 - 1942
  • [27] Effect of dynamic hip screw on the treatment of femoral neck fracture in the elderly
    Zhao Wenbo
    Liu Lei
    Zhang Hui
    Fang Yue
    Pei Fuxing
    Yang Tianfu
    CHINESE JOURNAL OF TRAUMATOLOGY, 2014, 17 (02) : 69 - 72
  • [28] Effect of dynamic hip screw on the treatment of femoral neck fracture in the elderly
    Zhao Wenbo
    Liu Lei
    Zhang Hui
    Fang Yue
    Pei Fuxing
    Yang Tianfu
    中华创伤杂志(英文版), 2014, 17 (02) : 69 - 72
  • [29] Four quadrant parallel peripheral screw fixation for displaced femoral neck fractures in elderly patients
    Bhava R. J. Satish
    Atmakuri V. Ranganadham
    Karruppasamy Ramalingam
    Sujit Kumar Tripathy
    Indian Journal of Orthopaedics, 2013, 47 : 174 - 181
  • [30] Four quadrant parallel peripheral screw fixation for displaced femoral neck fractures in elderly patients
    Satish, Bhava R. J.
    Ranganadham, Atmakuri V.
    Ramalingam, Karruppasamy
    Tripathy, Sujit Kumar
    INDIAN JOURNAL OF ORTHOPAEDICS, 2013, 47 (02) : 174 - 181