Pulse transit time: validation of blood pressure measurement under positive airway pressure ventilation

被引:19
|
作者
Schmalgemeier, Heidi [1 ]
Bitter, Thomas [1 ]
Bartsch, Stephan [1 ]
Bullert, Kevin [1 ]
Fischbach, Thomas [1 ]
Eckert, Siegfried [1 ]
Horstkotte, Dieter [1 ]
Oldenburg, Olaf [1 ]
机构
[1] Ruhr Univ Bochum, Univ Hosp, Heart & Diabet Ctr N Rhine Westphalia, Dept Cardiol, D-32545 Bad Oeynhausen, Germany
关键词
Pulse transit time; Arterial blood pressure measurement; Continuous positive airway pressure (CPAP); Sleep disordered breathing; OBSTRUCTIVE SLEEP-APNEA; HEART-FAILURE; RISK; ECG;
D O I
10.1007/s11325-011-0609-7
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The objective of the present study was to validate noninvasive, continuous blood pressure (BP) measurement using pulse transit time (PTT) to represent absolute values and detect BP changes under continuous positive airway pressure (CPAP) treatment. We applied CPAP to 78 patients of a cardiological sleep lab using 0 (baseline), 4, 8, and 12 cmH(2)O for 10 min at every level and measured BP simultaneous via PTT-based method and standard oscillometric method (OM). Quality of signal perception was acceptable to convert PTT into BP values in 64 patients (82%). When comparing both methods, we found a strong linear correlation of systolic and diastolic BP (baseline, r = 0.94 for systolic BP; r = 0.95 for diastolic BP, p < 0.001) while no significant differences between absolute values obtained with OM and PTT measurement. Mean bias at baseline was 4.1 +/- 3.2 mmHg for systolic BP and 2.3 +/- 2.2 mmHg for diastolic BP. With increasing CPAP levels, PTT and OM measurements differed continuously up to a systolic difference of 6.6 +/- 4.9 mmHg and a diastolic difference of 4.4 +/- 3.5 mmHg. There was no definite trend of PTT method to either over- or underestimate BP. We found that PTT- and OM-based BP results are closely correlated while applying CPAP over a period of 40 min. With higher CPAP level, bias between both methods increased.
引用
收藏
页码:1105 / 1112
页数:8
相关论文
共 50 条
  • [21] Validation of blood pressure monitoring using pulse transit time in heart failure patients with Cheyne–Stokes respiration undergoing adaptive servoventilation therapy
    Jens Spießhöfer
    Jessica Heinrich
    Thomas Bitter
    Christina Efken
    Roman Lehmann
    Siegfried Eckert
    Dieter Horstkotte
    Olaf Oldenburg
    Sleep and Breathing, 2014, 18 : 411 - 421
  • [22] Prototype of Wearable Device for Blood Pressure using Pulse Transit Time
    Bunkum, Manao
    Wanluk, Nutthanan
    Visitsattapongse, Sarinporn
    13TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2021), 2018,
  • [23] An implantable optical blood pressure sensor based on pulse transit time
    Fiala, Jens
    Bingger, Philipp
    Ruh, Dominic
    Foerster, Katharina
    Heilmann, Claudia
    Beyersdorf, Friedhelm
    Zappe, Hans
    Seifert, Andreas
    BIOMEDICAL MICRODEVICES, 2013, 15 (01) : 73 - 81
  • [24] OSAHS treatment with continuous positive airway pressure (CPAP) ventilation
    Portier, F.
    Frija, E. Orvoen
    Chavaillon, J. -M.
    Lerousseau, L.
    Degat, O. Reybet
    Leger, D.
    Meurice, J. -C.
    REVUE DES MALADIES RESPIRATOIRES, 2010, 27 : S137 - S145
  • [25] Pulse Transit Time and Blood Pressure During Cardiopulmonary Exercise Tests
    Wibmer, T.
    Doering, K.
    Kropf-Sanchen, C.
    Ruediger, S.
    Blanta, I.
    Stoiber, K. M.
    Rottbauer, W.
    Schumann, C.
    PHYSIOLOGICAL RESEARCH, 2014, 63 (03) : 287 - 296
  • [26] An implantable optical blood pressure sensor based on pulse transit time
    Jens Fiala
    Philipp Bingger
    Dominic Ruh
    Katharina Foerster
    Claudia Heilmann
    Friedhelm Beyersdorf
    Hans Zappe
    Andreas Seifert
    Biomedical Microdevices, 2013, 15 : 73 - 81
  • [27] Estimation of pulse transit time using two diametric blood pressure waveform measurements
    Hahn, Jin-Oh
    Reisner, Andrew T.
    Asada, H. Harry
    MEDICAL ENGINEERING & PHYSICS, 2010, 32 (07) : 753 - 759
  • [28] The influence of heart rate on the relationship between pulse transit time and systolic blood pressure
    Fu, Zhizhong
    Song, Xinyue
    Qin, Tianyi
    Chen, Yifan
    Ding, Xiaorong
    PHYSIOLOGICAL MEASUREMENT, 2024, 45 (10)
  • [29] Pulse transit time-estimated blood pressure: a comparison of beat-to-beat and intermittent measurement
    Hoshide, Satoshi
    Yoshihisa, Akiomi
    Tsuchida, Fumihiro
    Mizuno, Hiroyuki
    Teragawa, Hiroki
    Kasai, Takatoshi
    Koito, Hitoshi
    Ando, Shin-ichi
    Watanabe, Yoshihiko
    Takeishi, Yasuchika
    Kario, Kazuomi
    HYPERTENSION RESEARCH, 2022, 45 (06) : 1001 - 1007
  • [30] Continuous Non-Invasive Blood Pressure Measurement Using Pulse Transit Time in Children and Adolescents
    Zagrada, Elena
    Krickau, Tobias
    Rascher, Wolfgang
    KLINISCHE PADIATRIE, 2019, 231 (02): : 67 - 73