Pulse transit time: validation of blood pressure measurement under positive airway pressure ventilation

被引:19
|
作者
Schmalgemeier, Heidi [1 ]
Bitter, Thomas [1 ]
Bartsch, Stephan [1 ]
Bullert, Kevin [1 ]
Fischbach, Thomas [1 ]
Eckert, Siegfried [1 ]
Horstkotte, Dieter [1 ]
Oldenburg, Olaf [1 ]
机构
[1] Ruhr Univ Bochum, Univ Hosp, Heart & Diabet Ctr N Rhine Westphalia, Dept Cardiol, D-32545 Bad Oeynhausen, Germany
关键词
Pulse transit time; Arterial blood pressure measurement; Continuous positive airway pressure (CPAP); Sleep disordered breathing; OBSTRUCTIVE SLEEP-APNEA; HEART-FAILURE; RISK; ECG;
D O I
10.1007/s11325-011-0609-7
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The objective of the present study was to validate noninvasive, continuous blood pressure (BP) measurement using pulse transit time (PTT) to represent absolute values and detect BP changes under continuous positive airway pressure (CPAP) treatment. We applied CPAP to 78 patients of a cardiological sleep lab using 0 (baseline), 4, 8, and 12 cmH(2)O for 10 min at every level and measured BP simultaneous via PTT-based method and standard oscillometric method (OM). Quality of signal perception was acceptable to convert PTT into BP values in 64 patients (82%). When comparing both methods, we found a strong linear correlation of systolic and diastolic BP (baseline, r = 0.94 for systolic BP; r = 0.95 for diastolic BP, p < 0.001) while no significant differences between absolute values obtained with OM and PTT measurement. Mean bias at baseline was 4.1 +/- 3.2 mmHg for systolic BP and 2.3 +/- 2.2 mmHg for diastolic BP. With increasing CPAP levels, PTT and OM measurements differed continuously up to a systolic difference of 6.6 +/- 4.9 mmHg and a diastolic difference of 4.4 +/- 3.5 mmHg. There was no definite trend of PTT method to either over- or underestimate BP. We found that PTT- and OM-based BP results are closely correlated while applying CPAP over a period of 40 min. With higher CPAP level, bias between both methods increased.
引用
收藏
页码:1105 / 1112
页数:8
相关论文
共 50 条
  • [1] Pulse transit time: validation of blood pressure measurement under positive airway pressure ventilation
    Heidi Schmalgemeier
    Thomas Bitter
    Stephan Bartsch
    Kevin Bullert
    Thomas Fischbach
    Siegfried Eckert
    Dieter Horstkotte
    Olaf Oldenburg
    Sleep and Breathing, 2012, 16 : 1105 - 1112
  • [2] Continuous Noninvasive blood pressure measurement by pulse transit time
    Fung, P
    Dumont, G
    Ries, C
    Mott, C
    Ansermino, M
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 738 - 741
  • [3] Effects of continuous positive airway pressure on very short-term blood pressure variability associated with sleep-disordered breathing by pulse transit time-based blood pressure measurements
    Misaka, Tomofumi
    Yoshihisa, Akiomi
    Yokokawa, Tetsuro
    Takeishi, Yasuchika
    JOURNAL OF HYPERTENSION, 2023, 41 (05) : 733 - 740
  • [4] Modeling of pulse transit time under the effects of hydrostatic pressure for cuffless blood pressure measurements
    Poon, Carmen C. Y.
    Zhang, Yuan-Ting
    Liu, Yinbo
    2006 3RD IEEE/EMBS INTERNATIONAL SUMMER SCHOOL ON MEDICAL DEVICES AND BIOSENSORS, 2006, : 65 - +
  • [5] Blood Pressure Measurement from Photo-plethysmography to Pulse Transit Time
    Myint, C. Z.
    Lim, King Hann
    Wong, Kiing Ing
    Gopalai, Alpha Agape
    Oo, Min Zin
    2014 IEEE CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES), 2014, : 496 - 501
  • [6] Pulse transit time technique for cuffless unobtrusive blood pressure measurement: from theory to algorithm
    Ding, Xiaorong
    Zhang, Yuan-Ting
    BIOMEDICAL ENGINEERING LETTERS, 2019, 9 (01) : 37 - 52
  • [7] Non-contact Blood Pressure Measurement Based on Pulse Transit Time
    Chen Pengyong
    Zhou Zuofeng
    Zhao Ting
    Cao Jianzhong
    Yang Hongtao
    TENTH INTERNATIONAL CONFERENCE ON DIGITAL IMAGE PROCESSING (ICDIP 2018), 2018, 10806
  • [8] Smartphone-based Continuous Blood Pressure Measurement Using Pulse Transit Time
    Gholamhosseini, Hamid
    Meintjes, Andries
    Baig, Mirza
    Linden, Maria
    PHEALTH 2016, 2016, 224 : 84 - 89
  • [9] A novel calibration method for noninvasive blood pressure measurement using pulse transit time
    Yan, Y. S.
    Zhang, Y. T.
    2007 4TH IEEE/EMBS INTERNATIONAL SUMMER SCHOOL AND SYMPOSIUM ON MEDICAL DEVICES AND BIOSENSORS, 2007, : 1 - +
  • [10] Continuous blood pressure measurement by using the pulse transit time: comparison to a cuff-based method
    Gesche, Heiko
    Grosskurth, Detlef
    Kuechler, Gert
    Patzak, Andreas
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2012, 112 (01) : 309 - 315