Evaluation of the effect of an offset implant configuration in the posterior maxilla with external hexagon implant platform: A 3-dimensional finite element analysis

被引:23
作者
de Souza Batista, Victor Eduardo [1 ]
Verri, Fellippo Ramos [2 ]
de Faria Almeida, Daniel Augusto [3 ]
Santiago Junior, Joel Ferreira [4 ]
Araujo Lemos, Cleidiel Aparecido [1 ]
Pellizzer, Eduardo Piza [2 ]
机构
[1] Sao Paulo State Univ, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, Grad Program Dent, Sao Paulo, Brazil
[2] Sao Paulo State Univ, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, Sao Paulo, Brazil
[3] Univ Fed Alfenas, Sch Dent, Alfenas, MG, Brazil
[4] Univ Sagrado Coracao, Dept Hlth Sci, Sao Paulo, Brazil
关键词
STRAIN-GAUGE ANALYSIS; STRESS-DISTRIBUTION; DENTAL IMPLANTS; INTERNAL HEXAGON; SUPPORTED RESTORATIONS; BONE STRESS; PROSTHESES; PLACEMENT; CROWN; QUALITY;
D O I
10.1016/j.prosdent.2016.10.033
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Slight offset of the central implant in 3-unit implant-supported prostheses has been reported to improve biomechanical behavior. However, studies that assessed the effects of an offset implant configuration in the posterior maxilla are scarce. Purpose. The purpose of this 3-dimensional (3D) finite element analysis was to assess the effects of splinting in 3-unit implant-supported prostheses with varying implant positions (straight-line or offset configuration) in terms of the stress/strain distribution on bone tissue and the stress distribution on abutment screws. Material and methods. Three 3D models were used to simulate a posterior maxilla bone block (type IV): straight-line implants supporting single crowns (model M1), straight-line implants supporting 3 -unit splinted fixed dental prosthesis (model M2), and an offset implant configuration supporting 3 -unit splinted fixed dental prosthesis (model M3). The applied forces were 400 N axially and 200 N obliquely. The type of implant platform simulated was an external hexagon. von Mises stress on the abutment screws was measured, and the maximum principal stress and microstrain values were used to perform cortical bone tissue analysis. Analysis of variance (ANOVA) and the Tukey honest significant differences post hoc test were used to determine the significance of the results and interactions among the main variables (alpha=.05). Results. In all models, oblique load increased the stress on abutment screws and bone tissue and the microstrain on bone tissue. Model M3 decreased the stress concentration on the abutment screws and bone tissue. With regard to microstrain distribution, model M3 had the smallest values, and M1 and M2 had similar values. Conclusions. Splinting associated with an offset implant configuration was effective for decreasing the stress on abutment screws and bone tissue and the microstrain on bone tissue.
引用
收藏
页码:363 / 371
页数:9
相关论文
共 37 条
[1]   Straight and Offset Implant Placement under Axial and Nonaxial Loads in Implant-Supported Prostheses: Strain Gauge Analysis [J].
Abreu, Celina Wanderley ;
Nishioka, Renato Sussumu ;
Balducci, Ivan ;
Consani, Rafael Leonardo Xediek .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2012, 21 (07) :535-539
[2]   The staggered installation of dental implants and its effect on bone stresses [J].
Abu-Hammad, Osama ;
Khraisat, Ameen ;
Dar-Odeh, Najla ;
Jagger, Daryll C. ;
Hammerle, Christoph H. F. .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2007, 9 (03) :121-127
[3]  
Akça K, 2001, INT J ORAL MAX IMPL, V16, P722
[4]   STRESS-DISTRIBUTION IN METAL-CERAMIC CROWNS WITH A FACIAL PORCELAIN MARGIN [J].
ANUSAVICE, KJ ;
HOJJATIE, B .
JOURNAL OF DENTAL RESEARCH, 1987, 66 (09) :1493-1498
[5]   A finite element analysis of stress distribution in bone tissue surrounding uncoupled or splinted dental implants [J].
Bergkvist, Goran ;
Simonsson, Kjell ;
Rydberg, Kristofer ;
Johansson, Fredrik ;
Derand, Tore .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2008, 10 (01) :40-46
[6]   The influence of the location of load transfer on strains around implants supporting four unit cement-retained fixed prostheses:: in vitro evaluation of axial versus off-set loading [J].
Çehreli, MC ;
Iplikçioglu, H ;
Bilir, ÖG .
JOURNAL OF ORAL REHABILITATION, 2002, 29 (04) :394-400
[7]   Influence of Tapered and External Hexagon Connections on Bone Stresses Around Tilted Dental Implants: Three-Dimensional Finite Element Method With Statistical Analysis [J].
de Faria Almeida, Daniel Augusto ;
Pellizzer, Eduardo Piza ;
Verri, Fellippo Ramos ;
Santiago, Joel Ferreira, Jr. ;
Perri de Carvalho, Paulo Segio .
JOURNAL OF PERIODONTOLOGY, 2014, 85 (02) :261-269
[8]   The Effect of Offset Implant Configuration on Bone Stress Distribution: A Systematic Review [J].
de Souza Batista, Victor Eduardo ;
Santiago Junior, Joel Ferreira ;
de Faria Almeida, Daniel Augusto ;
de Toledo Piza Lopes, Leonardo Ferreira ;
Verri, Fellippo Ramos ;
Pellizzer, Eduardo Piza .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2015, 24 (02) :93-99
[9]   Effects of cantilever design and material on stress distribution in fixed partial dentures - a finite element analysis [J].
Eraslan, O ;
Sevimay, M ;
Usumez, A ;
Eskitascioglu, G .
JOURNAL OF ORAL REHABILITATION, 2005, 32 (04) :273-278
[10]   Bone's mechanostat: A 2003 update [J].
Frost, HM .
ANATOMICAL RECORD PART A-DISCOVERIES IN MOLECULAR CELLULAR AND EVOLUTIONARY BIOLOGY, 2003, 275A (02) :1081-1101