A label-free electrochemical immunosensor based on gold nanoparticles for detection of paraoxon

被引:84
作者
Hu, SQ
Xie, JW
Xu, QH
Rong, KT
Shen, GL [1 ]
Yu, RQ
机构
[1] Hunan Univ, Coll Chem & Chem Engn, State Key Lab Chemo Biosensing Technol & Chemomet, Changsha 410082, Peoples R China
[2] Zhu Zhou Teachers Coll, Dept Chem, Zhuzhou 410082, Peoples R China
[3] Beijing Inst Pharmacol & Toxicol, Beijing 100850, Peoples R China
关键词
immunosensor; gold nanoparticles; detection of paraoxon;
D O I
10.1016/S0039-9140(03)00368-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrochemical immunosensor for the direct determination of paraoxon has been developed based on the biocomposites of gold nanoparticles loaded with paraoxon antibodies. The biocomposites are immobilized on the glassy carbon electrode (GCE) using Nafion membrane. On the immunosensor prepared paraoxon shows well-shaped CV with reduction and oxidation peaks located -0.08 and -0.03 mV versus SCE, respectively. The detection of paraoxon performed at -0.03 mV is beneficial for guaranteeing sufficient selectivity. The amount of the biocomposite consisting gold nanoparticles loaded with antibodies and the volume of Nafion solution used for fabricating the immunosensor have been studied to ensure sensitivity and conductivity of the immunosensor. The immunosensor has been employed for monitoring the concentrations of paraoxon in aqueous samples up to 1920 mug l(-1) with a detection limit of 12 mug l(-1). (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:769 / 777
页数:9
相关论文
共 23 条
[1]   A glucose biosensor based on electrodeposited biocomposites of gold nanoparticles and glucose oxidase enzyme [J].
Bharathi, S ;
Nogami, M .
ANALYST, 2001, 126 (11) :1919-1922
[2]   Electrochemical and spectroscopic studies of nitrophenyl moieties immobilized on gold nanoparticles [J].
Chen, SW ;
Huang, K .
LANGMUIR, 2000, 16 (04) :2014-2018
[3]  
Chough SH, 2002, ELECTROANAL, V14, P273, DOI 10.1002/1521-4109(200202)14:4<273::AID-ELAN273>3.0.CO
[4]  
2-5
[5]   Direct electron transfer based tri-enzyme electrode for monitoring of organophosphorus pesticides [J].
DiehlFaxon, J ;
Ghindilis, AL ;
Atanasov, P ;
Wilkins, E .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 36 (1-3) :448-457
[6]   Selective colorimetric detection of polynucleotides based on the distance-dependent optical properties of gold nanoparticles [J].
Elghanian, R ;
Storhoff, JJ ;
Mucic, RC ;
Letsinger, RL ;
Mirkin, CA .
SCIENCE, 1997, 277 (5329) :1078-1081
[7]  
ELLENS L, 1998, MED FAC LANDBOUWW RI, V53, P20358
[8]   Use of colloidal gold surface plasmon resonance peak shift to infer affinity constants from the interactions between protein antigens and antibodies specific for single or multiple epitopes [J].
Englebienne, P .
ANALYST, 1998, 123 (07) :1599-1603
[9]   Disposable potentiometric enzyme sensor for direct determination of organophosphorus insecticides [J].
Gäberlein, S ;
Knoll, M ;
Spener, F ;
Zaborosch, C .
ANALYST, 2000, 125 (12) :2274-2279
[10]   Silver electrodeposition catalyzed by colloidal gold on carbon paste electrode:: application to biotin-streptavidin interaction monitoring [J].
González-García, MB ;
Costa-García, A .
BIOSENSORS & BIOELECTRONICS, 2000, 15 (11-12) :663-670