Rapid prototyping to create vascular replicas from CT scan data: Making tools to teach, rehearse, and choose treatment strategies

被引:60
作者
Knox, K
Kerber, CW
Singel, SA
Bailey, MJ
Imbesi, SG
机构
[1] Univ Calif San Diego, Med Ctr, Dept Radiol, San Diego, CA 92103 USA
[2] Univ Calif San Diego, Med Ctr, Dept Neurosurg, San Diego, CA 92103 USA
[3] Univ Calif San Diego, Supercomp Ctr, San Diego, CA 92103 USA
关键词
computed tomographic angiography; arterial replicas; arterial models; atherosclerosis; carotid artery; cerebral aneurysm; stereolithography;
D O I
10.1002/ccd.20333
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Our goal was to develop and prove the accuracy of a system that would allow us to re-create live patient arterial pathology. Anatomically accurate replicas of blood vessels could allow physicians to teach and practice dangerous interventional techniques and might also be used to gather basic physiologic information. The preparation of replicas has, until now, depended on acquisition of fresh cadaver material. Using rapid prototyping, it should be able to replicate vascular pathology in a live patient. We obtained CT angiographic scan data from two patients with known arterial abnormalities. We took such data and, using proprietary software, created a 3D replica using a commercially available rapid prototyping machine. From the prototypes, using a lost wax technique, we created vessel replicas, placed those replicas in the CT scanner, then compared those images with the original scans. Comparison of the images made directly from the patient and from the replica showed that with each step, the relationships were maintained, remaining within 3% of the original, but some smoothing occurred in the final computer manipulation. From routinely obtainable CT angiographic data, it is possible to create accurate replicas of human vascular pathology with the aid of commercially available stereolithography equipment. Visual analysis of the images appeared to be as important as the measurements. With 64 and 128 slice detector scanners becoming available, acquisition times fall enough that we should be able to model rapidly moving structures such as the aortic root. (c) 2005 Wiley-Liss, Inc.
引用
收藏
页码:47 / 53
页数:7
相关论文
共 40 条
  • [1] Accuracy and precision of time-averaged flow as measured by nontriggered 2D phase-contrast MR angiography, a phantom evaluation
    Bakker, CJG
    Kouwenhoven, M
    Hartkamp, MJ
    Hoogeveen, RM
    Mali, WPTM
    [J]. MAGNETIC RESONANCE IMAGING, 1995, 13 (07) : 959 - 965
  • [2] Flexible tubular replicas of abdominal aortic aneurysms
    Berry, E
    Marsden, A
    Dalgarno, KW
    Kessel, D
    Scott, DJA
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2002, 216 (H3) : 211 - 214
  • [3] Rapid prototyping: The future of trauma surgery?
    Brown, GA
    Firoozbakhsh, K
    DeCoster, TA
    Reyna, JR
    Moneim, M
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A : 49 - 55
  • [4] Analysis of errors in medical rapid prototyping models
    Choi, JY
    Choi, JH
    Kim, NK
    Kim, Y
    Lee, JK
    Kim, MK
    Lee, JH
    Kim, MJ
    [J]. INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2002, 31 (01) : 23 - 32
  • [5] CHONG BW, 1994, AM J NEURORADIOL, V15, P733
  • [6] Foutrakis GN, 1999, AM J NEURORADIOL, V20, P1309
  • [7] Gailloud P, 1999, AM J NEURORADIOL, V20, P291
  • [8] Computer-aided 3-D simulation and prediction of craniofacial surgery: a new approach
    Girod, S
    Teschner, M
    Schrell, U
    Kevekordes, B
    Girod, B
    [J]. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2001, 29 (03) : 156 - 158
  • [9] Estimating hospital deaths due to medical errors - Preventability is in the eye of the reviewer
    Hayward, RA
    Hofer, TP
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2001, 286 (04): : 415 - 420
  • [10] Hoogeveen RM, 1999, MAGNET RESON MED, V41, P520, DOI 10.1002/(SICI)1522-2594(199903)41:3<520::AID-MRM14>3.0.CO