Structures at risk from pedicle screws in the proximal thoracic spine: computed tomography evaluation

被引:12
作者
Cardoso, Mario J. [2 ]
Helgeson, Melvin D. [1 ]
Paik, Haines [1 ]
Dmitriev, Anton E. [1 ]
Lehman, Ronald A., Jr. [1 ]
Rosner, Michael K. [2 ]
机构
[1] Walter Reed Army Med Ctr, Dept Orthopaed & Rehabil, Washington, DC 20307 USA
[2] Walter Reed Army Med Ctr, Neurosurg Serv, Washington, DC 20307 USA
关键词
Pedicle screws; Thoracic spine; Esophagus; Trachea; IDIOPATHIC SCOLIOSIS; PLACEMENT; FIXATION; INSTRUMENTATION; AORTA; SAFE; ACCURACY;
D O I
10.1016/j.spinee.2010.08.020
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: Pedicle screw placement in the proximal thoracic spine may result in unwanted bicortical breach. An understanding of the potential structures at risk is paramount to safe screw placement. PURPOSE: To assess the anatomic location of structures at risk with the placement of bicortical pedicle screw fixation in the proximal thoracic spine. STUDY DESIGN: Retrospective radiographic review. PATIENT SAMPLE: Twenty patients with dedicated computed tomography (CT) scans of the thoracic spine. OUTCOME MEASURES: Radiographic parameters on CT. METHODS AND MATERIALS: Computed tomography was performed on 20 patients and analyzed from T1 to T4 for proximity of major structures at risk with breach of the anterior vertebral body cortex from pedicle screw placement. Descriptive statistics, analyses of variance and post hoc paired t tests were used to analyze screw position relative to the esophagus, trachea, aortic arch, carotid, and vertebral arteries. RESULTS: One hundred sixty potential anterior cortical violation positions were analyzed. Left-sided pedicle screws posed a significantly higher risk (p<.05) to the esophagus at T1-T3; in particular, the left T2 screw was significantly closer (p<.05). Right-sided pedicle screws posed a significantly higher risk to the trachea at T2 T4 (p<.05). The right T3 and T4 screws posed the greatest risk to the trachea and right main bronchus, respectively (p<.05). The carotid and vertebral arteries were not at risk for injury. The aortic arch was present at T4 in 70% of patients and was not at risk. CONCLUSIONS: Careful preoperative evaluation with CT is warranted to determine anatomic structures at risk when placing proximal thoracic pedicle screws. Left-sided screws pose the greatest risk to the esophagus; right-sided screws pose the greatest risk to the trachea. The carotid and vertebral arteries, along with the aortic arch are at minimal risk for injury. Published by Elsevier Inc.
引用
收藏
页码:905 / 909
页数:5
相关论文
共 17 条
[1]   In vivo accuracy of thoracic pedicle screws [J].
Belmont, PJ ;
Klemme, WR ;
Dhawan, A ;
Polly, DW .
SPINE, 2001, 26 (21) :2340-2346
[2]   ACCURACY OF PEDICULAR SCREW PLACEMENT INVIVO [J].
GERTZBEIN, SD ;
ROBBINS, SE .
SPINE, 1990, 15 (01) :11-14
[3]  
JENDRISAK MD, 1986, SURGERY, V99, P631
[4]   Delayed presentation of aortic injury by pedicle screws: Report of two cases and review of the literature [J].
Kakkos, Stavros K. ;
Shepard, Alexander D. .
JOURNAL OF VASCULAR SURGERY, 2008, 47 (05) :1074-1082
[5]   Pedicle screw placement with a free hand technique in thoracolumbar spine: Is it safe? [J].
Karapinar, Levent ;
Erel, Nuri ;
Ozturk, Hasan ;
Altay, Taskin ;
Kaya, Ahmet .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2008, 21 (01) :63-67
[6]   Free hand pedicle screw placement in the thoracic spine: Is it safe? [J].
Kim, YJ ;
Lenke, LG ;
Bridwell, KH ;
Cho, YSS ;
Riew, KD .
SPINE, 2004, 29 (03) :333-342
[7]   Structures at risk following anterior instrumented spinal fusion for thoracic adolescent idiopathic scoliosis [J].
Kuklo, TR ;
Lehman, RA ;
Lenke, LG .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2005, 18 :S58-S64
[8]   Straight-forward versus anatomic trajectory technique of thoracic pedicle screw fixation: A biomechanical analysis [J].
Lehman, RA ;
Polly, DW ;
Kuklo, TR ;
Cunningham, B ;
Kirk, KL ;
Belmont, PJ .
SPINE, 2003, 28 (18) :2058-2065
[9]   Pedicle screw instrumentation of the thoracic spine in idiopathic scoliosis [J].
Liljenqvist, UR ;
Halm, HFH ;
Link, TM .
SPINE, 1997, 22 (19) :2239-2245
[10]   PENETRATION OF A SCREW INTO THE THORACIC AORTA IN ANTERIOR SPINAL INSTRUMENTATION - A CASE-REPORT [J].
MATSUZAKI, H ;
TOKUHASHI, Y ;
WAKABAYASHI, K ;
KITAMURA, S .
SPINE, 1993, 18 (15) :2327-2331