Study and realization of a transfer detector based on porous silicon for radiometric measurements

被引:2
|
作者
Ben Achour, Z.
Touayar, O.
Akkari, E.
Bastie, J.
Bessais, B.
Ben Brahim, J.
机构
[1] Inst Natl Sci Appl Technol, Lab Metrol Rayonnements, Tunis 1080, Tunisia
[2] Inst Natl Metrol, Bur Natl Metrol, Head Team Radiomet & Photomet, F-75141 Paris, France
[3] Inst Natl Rech Sci & Tech, Lab Photovoltaique & Mat Semiconduct, Hammam 2050, Tunisia
关键词
radiometric scale; transfer detector; photodiode; porous silicon; spatial responsivity; linearity; spectral responsivity; TRAP PYROELECTRIC DETECTOR; ESTABLISHMENT;
D O I
10.1016/j.nima.2006.12.035
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A photodetector of high accuracy has been developed at the "Laboratoire de Metrologie des Rayonnements (L.M.R)-Tunisia" to serve as a transfer detector for optical power measurements in the visible spectral range, i.e. wavelength from 400 to 800nm. The originality of the work, comparing with other ones, consists of realizing a pn(+) junction with a n(+) porous silicon layer on the front face and a zinc oxide (ZnO) film as a transparent electrode above the porous layer. This detector's structure permits to the porous silicon layer to trap the incident optical radiation and to reduce the reflection coefficient fluctuations of the front face to a value of about 7%. The uncertainties relating to the spatial response uniformity of the detector and especially in the central area with 5 mm diameter are equal to 0.5-0.7% for vertical and horizontal directions, respectively. The realized photodetector can roughly reach 10mW of measured optical power. This value represents an earning of one decade comparing with commercial photodiodes that cannot measure optical power beyond 1 mW. The photodetector presents a linearity with a cumulated deviation of a few 10(-4) through more than 4 decades with an uncertainty of 1.5 x 10(-4) at 1 sigma level. The photodetector was also indirectly calibrated with the cryogenic radiometer of the "Institut National de Wtrologie (INM)-France" and provides a convenient standard with a relative standard uncertainty of a few 10(-3) at the 1 sigma level. This uncertainty is equivalent to commercial transfer detectors used in metrology laboratories. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:1117 / 1121
页数:5
相关论文
共 50 条
  • [31] Drift mobility measurements in porous silicon
    Tsybeskov, L
    Peng, C
    Fauchet, PM
    Gu, Q
    Schiff, EA
    AMORPHOUS SILICON TECHNOLOGY - 1996, 1996, 420 : 825 - 829
  • [32] Design and realization of highly stable porous silicon optical biosensor based on proteins from extremophiles
    De Stefano, Luca
    Rotrotia, Lucia
    Rea, Ilaria
    De Tommasi, Edoardo
    Vitale, Annalisa
    Rossi, Mose
    Rendina, Ivo
    D'Auria, Sabato
    OPTICAL SENSING TECHNOLOGY AND APPLICATIONS, 2007, 6585
  • [33] Development of an Enzyme-Based Photoluminescent Porous Silicon Detector for Chemical Warfare Agents
    Hart, Bradley R.
    Letant, Sonia E.
    Kane, Staci R.
    Hadi, Masood Z.
    Shields, Sharon J.
    Cheng, Tu-Chen
    Rastogi, Vipin K.
    Del Eckels, J.
    Reynolds, John G.
    ANTITERRORISM AND HOMELAND DEFENSE: POLYMERS AND MATERIALS, 2007, 980 : 39 - 56
  • [34] EXTENDING THE SPECTRAL RANGE OF SILICON-BASED DIRECT-BEAM SOLAR SPECTRAL RADIOMETRIC MEASUREMENTS
    OSTERWALD, CR
    EMERY, KA
    MYERS, DR
    RIORDAN, CJ
    CONFERENCE RECORD OF THE TWENTIETH IEEE PHOTOVOLTAIC SPECIALISTS CONFERENCE - 1988, VOLS 1-2, 1988, : 1246 - 1250
  • [35] Realization of porous silicon photonic bandgap optical sensor devices
    Patel, P. N.
    Mishra, Vivekanand
    JOURNAL OF OPTOELECTRONICS AND ADVANCED MATERIALS, 2014, 16 (3-4): : 269 - 275
  • [36] Nondestructive evaluation of metal contaminated silicon wafers using radiometric measurements
    Kalli, K
    Othonos, A
    Christofides, C
    Tardiff, F
    JOURNAL OF APPLIED PHYSICS, 1999, 86 (06) : 3064 - 3067
  • [37] THE DM2 SOLENOIDAL DETECTOR ON DCI AT ORSAY - REALIZATION AND MEASUREMENTS
    BAZIN, C
    COSTA, S
    DABIN, Y
    LEMEUR, G
    RENARD, M
    IEEE TRANSACTIONS ON MAGNETICS, 1981, 17 (05) : 1840 - 1842
  • [38] Advanced Study of Novel Radiation Detector based on Silicon Photomultiplier
    Osovizky, Alon
    Ginzburg, Dimitry
    Ghelman, Max
    Cohen-Zada, Ilan
    Pushkarsky, Vitaly
    Marcus, Eli
    Manor, Avi
    Kadmon, Yagil
    Cohen, Yosef
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 1552 - +
  • [40] Numerical study of the external flow effect on the heat transfer in a radiometric calorimeter dedicated to nuclear heating measurements
    Muraglia, M.
    Reynard-Carette, C.
    Brun, J.
    Carette, M.
    Lyoussi, A.
    Guimbal, P.
    Villard, J-F.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 295 - 301