Study and realization of a transfer detector based on porous silicon for radiometric measurements

被引:2
|
作者
Ben Achour, Z.
Touayar, O.
Akkari, E.
Bastie, J.
Bessais, B.
Ben Brahim, J.
机构
[1] Inst Natl Sci Appl Technol, Lab Metrol Rayonnements, Tunis 1080, Tunisia
[2] Inst Natl Metrol, Bur Natl Metrol, Head Team Radiomet & Photomet, F-75141 Paris, France
[3] Inst Natl Rech Sci & Tech, Lab Photovoltaique & Mat Semiconduct, Hammam 2050, Tunisia
关键词
radiometric scale; transfer detector; photodiode; porous silicon; spatial responsivity; linearity; spectral responsivity; TRAP PYROELECTRIC DETECTOR; ESTABLISHMENT;
D O I
10.1016/j.nima.2006.12.035
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A photodetector of high accuracy has been developed at the "Laboratoire de Metrologie des Rayonnements (L.M.R)-Tunisia" to serve as a transfer detector for optical power measurements in the visible spectral range, i.e. wavelength from 400 to 800nm. The originality of the work, comparing with other ones, consists of realizing a pn(+) junction with a n(+) porous silicon layer on the front face and a zinc oxide (ZnO) film as a transparent electrode above the porous layer. This detector's structure permits to the porous silicon layer to trap the incident optical radiation and to reduce the reflection coefficient fluctuations of the front face to a value of about 7%. The uncertainties relating to the spatial response uniformity of the detector and especially in the central area with 5 mm diameter are equal to 0.5-0.7% for vertical and horizontal directions, respectively. The realized photodetector can roughly reach 10mW of measured optical power. This value represents an earning of one decade comparing with commercial photodiodes that cannot measure optical power beyond 1 mW. The photodetector presents a linearity with a cumulated deviation of a few 10(-4) through more than 4 decades with an uncertainty of 1.5 x 10(-4) at 1 sigma level. The photodetector was also indirectly calibrated with the cryogenic radiometer of the "Institut National de Wtrologie (INM)-France" and provides a convenient standard with a relative standard uncertainty of a few 10(-3) at the 1 sigma level. This uncertainty is equivalent to commercial transfer detectors used in metrology laboratories. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:1117 / 1121
页数:5
相关论文
共 50 条
  • [11] Silicon-based UV detector prototypes using luminescent porous silicon films
    Peraza, Limarix
    Cruz, Madeline
    Estrada, Angel
    Navarro, Carlos
    Avalos, Javier
    Fonseca, Luis F.
    Resto, Oscar
    Weisz, S.Z.
    Materials Research Society Symposium - Proceedings, 1999, 536 : 123 - 128
  • [12] Realization of a radiometric head for measurements of ultraviolet total erythemal effective irradiance
    Pelizzo, Maria-Guglielmina
    Garoli, Denis
    Nicolosi, Piergiorgio
    APPLIED OPTICS, 2007, 46 (22) : 4977 - 4984
  • [13] Photothermal radiometric measurements on metal contaminated silicon wafers
    Kalli, K
    Othonos, A
    Christofides, C
    Tardiff, F
    PHOTOACOUSTIC AND PHOTOTHERMAL PHENOMENA: TENTH INTERNATIONAL CONFERENCE, 1999, 463 : 386 - 388
  • [14] Calmodulin Functionalized Porous Silicon Based Electrical Calcium Detector and its Comparison with Optical Detector
    Sen, Kaustav
    Sarkar, Tanusree
    Basu, Deeparati
    Hossain, Syed Minhaz
    Das, Jayoti
    SILICON, 2023, 15 (08) : 3637 - 3645
  • [15] Calmodulin Functionalized Porous Silicon Based Electrical Calcium Detector and its Comparison with Optical Detector
    Kaustav Sen
    Tanusree Sarkar
    Deeparati Basu
    Syed Minhaz Hossain
    Jayoti Das
    Silicon, 2023, 15 : 3637 - 3645
  • [16] Silicon-based UV detector prototypes using luminescent porous silicon films.
    Peraza, L
    Cruz, M
    Estrada, A
    Navarro, C
    Avalos, J
    Fonseca, LF
    Resto, O
    Weisz, SZ
    MICROCRYSTALLINE AND NANOCRYSTALLINE SEMICONDUCTORS-1998, 1999, 536 : 123 - 128
  • [17] Hydrogeological Survey, Radiometric Analysis and Field Parametric Measurements: A Combined Tool for the Study of Porous Aquifers
    Cuiuli, Enzo
    Procopio, Salvatore
    WATER, 2022, 14 (14)
  • [19] REALIZATION OF POROUS SILICON MEMBRANES FOR GAS SENSOR APPLICATIONS
    TALIERCIO, T
    DILHAN, M
    MASSONE, E
    GUE, AM
    FRAISSE, B
    FOUCARAN, A
    THIN SOLID FILMS, 1995, 255 (1-2) : 310 - 312
  • [20] Radiometric Transfer: Example-based Radiometric Linearization of Photographs
    Li, Han
    Peers, Pieter
    COMPUTER GRAPHICS FORUM, 2015, 34 (04) : 109 - 118