Study and realization of a transfer detector based on porous silicon for radiometric measurements

被引:2
|
作者
Ben Achour, Z.
Touayar, O.
Akkari, E.
Bastie, J.
Bessais, B.
Ben Brahim, J.
机构
[1] Inst Natl Sci Appl Technol, Lab Metrol Rayonnements, Tunis 1080, Tunisia
[2] Inst Natl Metrol, Bur Natl Metrol, Head Team Radiomet & Photomet, F-75141 Paris, France
[3] Inst Natl Rech Sci & Tech, Lab Photovoltaique & Mat Semiconduct, Hammam 2050, Tunisia
关键词
radiometric scale; transfer detector; photodiode; porous silicon; spatial responsivity; linearity; spectral responsivity; TRAP PYROELECTRIC DETECTOR; ESTABLISHMENT;
D O I
10.1016/j.nima.2006.12.035
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A photodetector of high accuracy has been developed at the "Laboratoire de Metrologie des Rayonnements (L.M.R)-Tunisia" to serve as a transfer detector for optical power measurements in the visible spectral range, i.e. wavelength from 400 to 800nm. The originality of the work, comparing with other ones, consists of realizing a pn(+) junction with a n(+) porous silicon layer on the front face and a zinc oxide (ZnO) film as a transparent electrode above the porous layer. This detector's structure permits to the porous silicon layer to trap the incident optical radiation and to reduce the reflection coefficient fluctuations of the front face to a value of about 7%. The uncertainties relating to the spatial response uniformity of the detector and especially in the central area with 5 mm diameter are equal to 0.5-0.7% for vertical and horizontal directions, respectively. The realized photodetector can roughly reach 10mW of measured optical power. This value represents an earning of one decade comparing with commercial photodiodes that cannot measure optical power beyond 1 mW. The photodetector presents a linearity with a cumulated deviation of a few 10(-4) through more than 4 decades with an uncertainty of 1.5 x 10(-4) at 1 sigma level. The photodetector was also indirectly calibrated with the cryogenic radiometer of the "Institut National de Wtrologie (INM)-France" and provides a convenient standard with a relative standard uncertainty of a few 10(-3) at the 1 sigma level. This uncertainty is equivalent to commercial transfer detectors used in metrology laboratories. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:1117 / 1121
页数:5
相关论文
共 50 条
  • [1] Radiometric realization of the candela with a trap detector
    Ikonen, E
    Karha, P
    Lassila, A
    Manoochehri, F
    Fagerlund, H
    Liedquist, L
    METROLOGIA, 1996, 32 (06) : 689 - 692
  • [2] Study and characterization of porous germanium for radiometric measurements
    Akkari, E.
    Benachour, Z.
    Aouida, S.
    Touayar, O.
    Bessais, B.
    Benbrahim, J.
    PHYSICA STATUS SOLIDI C - CURRENT TOPICS IN SOLID STATE PHYSICS, VOL 6, NO 7, 2009, 6 (07): : 1685 - +
  • [3] Study and realisation of an original silicon-germanium light trap detector for large band radiometric measurements
    Ben Achour, Z.
    Abbane, S.
    Touayar, O.
    Bonnier, G.
    INTERNATIONAL JOURNAL OF NANOTECHNOLOGY, 2015, 12 (8-9) : 708 - 722
  • [4] DETECTOR SCANNER FOR ACCURATE RADIOMETRIC MEASUREMENTS
    GEIST, J
    KNEISSL, GJ
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1967, 57 (11) : 1418 - &
  • [5] Porous silicon-based UV detector
    Min, NK
    Kang, CG
    Jin, JH
    Ko, JY
    Kim, SK
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2001, 39 : S63 - S66
  • [6] Realization of porous silicon based miniature fuel cells
    Pichonat, T
    Gauthier-Manuel, B
    JOURNAL OF POWER SOURCES, 2006, 154 (01) : 198 - 201
  • [7] Porous Silicon Based Violet-UV Detector
    Ahmed, Naser M.
    Hassan, Z.
    Alhardan, Naif
    Aldouri, Yarub
    Jassim, M. J.
    Hajar, Muhammad Anis Ibnu
    Bakhdri, S. K. Mohd
    Zaini, N. A. Ahmad
    INTERNATIONAL CONFERENCE ON NANOTECHNOLOGY - RESEARCH AND COMMERCIALIZATION 2011 (ICONT 2011), 2012, 1502 : 196 - 210
  • [8] Porous Silicon Based Moisture Detector in the ppmV Range
    Islam, T.
    Islam, S. S.
    Saha, H.
    SENSOR LETTERS, 2008, 6 (05) : 746 - 751
  • [9] Optical tunnel-trap detector for radiometric measurements
    Lehman, JH
    Cromer, CL
    METROLOGIA, 2000, 37 (05) : 477 - 480
  • [10] Effect of ethanol in an inorganic salt detector based on porous silicon
    Murillo, N.
    Rucavado, E.
    Ramirez-Porras, A.
    PHYSICA STATUS SOLIDI C - CURRENT TOPICS IN SOLID STATE PHYSICS, VOL 6, NO 7, 2009, 6 (07): : 1709 - +