Non-equilibrium thermodynamic model for liquefied natural gas storage tanks

被引:41
作者
Wang, Zhihao [1 ]
Sharafian, Amir [1 ]
Merida, Walter [1 ]
机构
[1] Univ British Columbia, Clean Energy Res Ctr, 2360 East Mall, Vancouver, BC V6T 1Z3, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Non-equilibrium model; Liquefied natural gas; Storage tank; Boil-off gas; Refueling station; Methane emissions; TURBULENT FREE-CONVECTION; CORRELATING EQUATIONS; HEAT-TRANSFER; LNG; LAMINAR; BOIL; PERFORMANCE; FLOW;
D O I
10.1016/j.energy.2019.116412
中图分类号
O414.1 [热力学];
学科分类号
摘要
A thermodynamic non-equilibrium model is introduced to evaluate the thermal performance of vertical and horizontal liquefied natural gas (LNG) storage tanks in refueling stations. This model incorporates a resistance-capacitance network to reduce the required computation time to several hours compared with the computational fluid dynamics (CFD) method which requires several days or weeks to run under high-performance computing. The accuracy of the non-equilibrium model is validated with two sets of experimental data, and thermodynamic equilibrium and CFD models, respectively. Our results indicate that the non-equilibrium and equilibrium models have a similar accuracy to predict the pressure and temperature changes in vertical and horizontal LNG storage tanks under stationary conditions. However, the equilibrium model fails to predict the tank performance under sudden pressure changes such as those produced via vapor return from heavy-duty trucks duringre fueling. In contrast, the non-equilibrium model accurately predicts the pressure of LNG storage tank under dynamic conditions. Our results also indicate that, compared to vertical tanks and under dynamic operating conditions, horizontal storage tanks can hold LNG for longer periods without methane release to the atmosphere. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页数:20
相关论文
共 53 条
[1]  
[Anonymous], 2017, UND NAT GAS LNG OPT
[2]  
[Anonymous], 2016, LNG STOR VESS
[3]  
ANSYS academic Research fluent, AC RES FLUENT
[4]  
Augustynowicz SD, 2005, CRYOGENIC THERMAL IN
[5]  
BEDUZ C, 1994, ADV CRYOG ENG, V39, P1749
[6]  
Bond M, 2004, PHYS REV E, V70, DOI 10.1103/PhysRevE.70.061605
[7]  
Chen X., 2014, Dependable and Secure Computing, IEEE Transactions on, P1, DOI [10.1371/journal.pone.0109577, DOI 10.1371/JOURNAL.PONE.0109577]
[8]  
Chidthaisong A, 2007, CLIMATE CHANGE 2007
[9]   Numerical analysis of convective flow and thermal stratification in a cryogenic storage tank [J].
Choi, Sung Woong ;
Lee, Woo Il ;
Kim, Han Sang .
NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2017, 71 (04) :402-422
[10]   CORRELATING EQUATIONS FOR LAMINAR AND TURBULENT FREE CONVECTION FROM A HORIZONTAL CYLINDER [J].
CHURCHILL, SW ;
CHU, HHS .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1975, 18 (09) :1049-1053