A New Prototype of Smart Wearable Monitoring System Solution for Alzheimer's Patients

被引:8
作者
Al-Naami, Bassam [1 ]
Abu Owida, Hamza [2 ]
Abu Mallouh, Mohammed [3 ]
Al-Naimat, Feras [2 ]
Agha, Moh'd [2 ]
Al-Hinnawi, Abdel-Razzak [4 ]
机构
[1] Hashemite Univ, Dept Biomed Engn, Zarqa, Jordan
[2] Al Ahliyya Amman Univ, Dept Med Engn, Amman, Jordan
[3] Hashemite Univ, Dept Mechatron Engn, Zarqa, Jordan
[4] Al Isra Univ, Fac Sci, Amman, Jordan
关键词
Alzheimer's disease; smart wearable medical device; fall down alert; Internet Cloud access; health care aids; Wi-Fi micro controller; SENSORS;
D O I
10.2147/MDER.S339855
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose: The daily life management of patients with Alzheimer's disease (AD) constitutes a significant and rapidly expanding health-care responsibility. In this study, an innovative prototype of a wireless-sensing smart wearable medical device (SWMD) is proposed as a multi-functions solution for Alzheimer patients. The SWMD is aimed to assemble three main biomedical engineering advances: 1) use of a Wi-Fi microcontroller, 2) simultaneous monitoring of a set of vital biomarkers, and 3) cautions of fall down conditions, in addition to GPS location indicator. Methods: The SWMD employs a Wi-Fi controller that is incorporated with electronic circuits to monitor three vital signals (temperature, heart rate, and oxygen saturation), fall down conditions in three directions (X, Y, and Z axis), and GPS location. The SWMD was connected to the Firebase Service (database hosted on the Internet Cloud). The proposed device was tested on 13 normal volunteers. The left side, right side, forward, and backward fall down conditions were assessed. The prototype's functions during daily activity such as rising hand, sitting down or standing up, and walking conditions were also assessed. Results: The three assembled functions were all successfully incorporated to build the SWDM device as a suggested solution offering real-time alerts during daily activity to AD patients. The Bland-Altman statistical test showed no significant difference (p-value >0.05) between the SWMD biomarkers' acquisition and the reference methods. The gyro/accelerator sensor yielded 93% sensitivity in fall down detection and 95% specificity during daily activities. The GPS yielded correct positioning of the SWDM holder, while the internet cloud allowed saving and managing all vital biomarkers daily. Conclusion: The SWMD is a possible solution for daily life support for AD patients. It incorporates three functions in one single device, GPS location indicator, monitoring set of biomarkers, and fall down alert, which are all controlled via a Wi-Fi micro controller on-line connected to Internet Cloud. It successfully would allow the management of the daily records as well as the real-time alerts to remote persons.
引用
收藏
页码:423 / 433
页数:11
相关论文
共 33 条
[1]   Usability Study of a wireless monitoring system among Alzheimer's disease elderly population [J].
Abbate, Stefano ;
Avvenuti, Marco ;
Light, Janet .
International Journal of Telemedicine and Applications, 2014,
[2]   MIMS: A Minimally Invasive Monitoring Sensor Platform [J].
Abbate, Stefano ;
Avvenuti, Marco ;
Light, Janet .
IEEE SENSORS JOURNAL, 2012, 12 (03) :677-684
[3]  
Aljehani SS, 2018, 2018 1ST INTERNATIONAL CONFERENCE ON COMPUTER APPLICATIONS & INFORMATION SECURITY (ICCAIS' 2018)
[4]   Assessing Agreement between Methods of Measurement [J].
Altman, Douglas G. ;
Bland, J. Martin .
CLINICAL CHEMISTRY, 2017, 63 (10) :1653-1654
[5]  
AnalogDevices.,, 2014, PULS OX HEART RAT SE
[6]  
Anzalone Patricia, 2008, Clin Nurs Res, V17, P251, DOI 10.1177/1054773808325050
[7]   NAVIX: A Wearable Navigation System for Visually Impaired Persons [J].
Bal, Debasish ;
Tusher, Md Munirul Islam ;
Rahman, Mizanur ;
Saymon, Md Salmanur Rahman .
2020 2ND INTERNATIONAL CONFERENCE ON SUSTAINABLE TECHNOLOGIES FOR INDUSTRY 4.0 (STI), 2020,
[8]  
Boppana L, 2019, TENCON IEEE REGION, P2466, DOI [10.1109/tencon.2019.8929412, 10.1109/TENCON.2019.8929412]
[9]  
Caring.com. ,, 2021, FREEDOM GUARDIAN WAT
[10]  
Chaitep T, 2017, 2017 14TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING/ELECTRONICS, COMPUTER, TELECOMMUNICATIONS AND INFORMATION TECHNOLOGY (ECTI-CON), P183, DOI 10.1109/ECTICon.2017.8096203