Mixed hemimicelles solid-phase extraction based on cetyltrimethylammonium bromide-coated nano-magnets Fe3O4 for the determination of chlorophenols in environmental water samples coupled with liquid chromatography/spectrophotometry detection

被引:201
|
作者
Li, Jidong [1 ,2 ]
Zhao, Xiaoli [1 ]
Shi, Yali [1 ]
Cai, Yaqi [1 ]
Mou, Shifen [1 ]
Jiang, Guibin [1 ]
机构
[1] Chinese Acad Sci, Res Ctr Ecoenvironm Sci, State Key Lab Environm Chem & Ecotoxicol, Beijing 100085, Peoples R China
[2] Gen Res Inst NonFerrous Met, Beijing 100088, Peoples R China
基金
中国国家自然科学基金;
关键词
nanoparticles; Fe3O4; magnetism; mixed hemimicelles; solid-phase extraction; chlorophenols;
D O I
10.1016/j.chroma.2007.12.028
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Mixed hemimicelles solid-phase extraction (SPE) based on cetyltrimethylammonium bromide (CTAB)-coated nano-magnets Fe3O4 was investigated for the preconcentration of four chlorophenols (CPs) in environmental water samples prior to HPLC-spectrophotometry determination in this paper. By the rapid isolating (about 5 min) of Fe3O4 nanoparticles (NPs) through placing a Nd-Fe-B strong magnet on the bottom of beaker, the time-consuming preconcentration process of loading large volume sample in conversional SPE method with a column can be avoided. The unique properties of Fe3O4 NPs such as high surface area and strong magnetism were utilized adequately in the SPE process. This novel separation method produced a high preconcentration rate and factor. A comprehensive study of the adsorption conditions such as the Fe3O4 NPs zeta-potential, CTAB added amounts, pH value, standing time and maximal extraction volume was also presented. Under optimized conditions, four analytes of 2-chlorophenol (2-CP), 2,4-dichlorophenol (2,4-DCP), 2,4,6-trichlorophenol (TCP) and pentachlorophenol (PCP) were quantitatively extracted. The method was then used to determine four CPs in five real environmental water samples. High concentration factors (700) were achieved for each of the analytes, with observed detection limits ranging between 0.11 and 0.15 mu g L-1. The accuracy of method was evaluated by recovery measurements on spiked samples. Good recovery results (83-98%) with satisfactory relative standard deviation (RSD) were achieved. It is important to note that satisfactory preconcentration factors and extraction recoveries for the four CPs were obtained with only a little amount of Fe3O4 NPs (0.1 g) and CTAB (60 mg). To the best of our knowledge, this was the first time a mixed hemimicelles SPE method based on Fe3O4 NPs magnetic separation had been used for the pretreatment of environmental water samples. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:24 / 31
页数:8
相关论文
共 50 条
  • [31] Determination of trace bisphenol A in environmental water by high-performance liquid chromatography using magnetic reduced graphene oxide based solid-phase extraction coupled with dispersive liquid-liquid microextraction
    Li, Danping
    Ma, Xiaoguo
    Wang, Rui
    Yu, Yumian
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2017, 409 (05) : 1165 - 1172
  • [32] Magnetic Solid-Phase Extraction Based on Fe3O4/g-C3N4 Nanocomposite for the Determination of Polychlorinated Biphenyls and Polychlorinated Diphenyl Ethers in Environmental Waters
    Ji, Dongliang
    Zhang, Meixing
    Geng, Xinxiang
    Zha, Zhenxing
    Li, Ying
    Yang, Jing
    Cui, Shihai
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2020, 20 (12) : 7469 - 7479
  • [33] Extraction and determination of flavonoids in fruit juices and vegetables using Fe3O4/SiO2 magnetic nanoparticles modified with mixed hemi/ad-micelle cetyltrimethylammonium bromide and high performance liquid chromatography
    Sani, Tahereh Harsij
    Hadjmohammadi, Mohammadreza
    Fatemi, Mohammad Hossein
    JOURNAL OF SEPARATION SCIENCE, 2020, 43 (07) : 1224 - 1231
  • [34] Chitosan-poly(m-phenylenediamine)@Fe3O4 nanocomposite for magnetic solid-phase extraction of polychlorinated biphenyls from water samples
    Liao, Qie Gen
    Wang, Dong Gen
    Luo, Lin Guang
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (29) : 7571 - 7579
  • [35] Optimized solid phase extraction based on diethyldithiocarbamate-coated Fe3O4 magnetic nanoparticles followed by ICP-OES for determination of Cd(II) and Ni(II) in rice and water samples
    Sereshti, Hassan
    Karimi, Maryam
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2014, 11 (04) : 1129 - 1136
  • [36] Optimized solid phase extraction based on diethyldithiocarbamate-coated Fe3O4 magnetic nanoparticles followed by ICP-OES for determination of Cd(II) and Ni(II) in rice and water samples
    Hassan Sereshti
    Maryam Karimi
    Journal of the Iranian Chemical Society, 2014, 11 : 1129 - 1136
  • [37] A novel dianionic amino acid ionic liquid-coated PEG 4000 modified Fe3O4 nanocomposite for the magnetic solid-phase extraction of trypsin
    Yang, Qin
    Wang, Yuzhi
    Zhang, Hongmei
    Xu, Kaijia
    Wei, Xiaoxiao
    Xu, Panli
    Zhou, Yigang
    TALANTA, 2017, 174 : 139 - 147
  • [38] Evaluation of Fe3O4@SiO2-MOF-177 as an advantageous adsorbent for magnetic solid-phase extraction of phenols in environmental water samples
    Wang, Guan-Hua
    Lei, Yong-Qian
    Song, Hua-Can
    ANALYTICAL METHODS, 2014, 6 (19) : 7842 - 7847
  • [39] Facile synthesis of multifunctional attapulgite/Fe3O4/polyaniline nanocomposites for magnetic dispersive solid phase extraction of benzoylurea insecticides in environmental water samples
    Yang, Xiaoling
    Qiao, Kexin
    Ye, Yiren
    Yang, Miyi
    Li, Jing
    Gao, Haixiang
    Zhang, Sanbing
    Zhou, Wenfeng
    Lu, Runhua
    ANALYTICA CHIMICA ACTA, 2016, 934 : 114 - 121
  • [40] Determination of trace bisphenol A in environmental water by high-performance liquid chromatography using magnetic reduced graphene oxide based solid-phase extraction coupled with dispersive liquid–liquid microextraction
    Danping Li
    Xiaoguo Ma
    Rui Wang
    Yumian Yu
    Analytical and Bioanalytical Chemistry, 2017, 409 : 1165 - 1172