SVR-EEMD: An Improved EEMD Method Based on Support Vector Regression Extension in PPG Signal Denoising

被引:6
作者
Liu, Guangda [1 ]
Hu, Xinlei [1 ]
Wang, Enhui [1 ]
Zhou, Ge [1 ]
Cai, Jing [1 ]
Zhang, Shang [1 ]
机构
[1] Jilin Univ, Coll Instrumentat & Elect Engn, Changchun 130026, Jilin, Peoples R China
关键词
EMPIRICAL MODE DECOMPOSITION; PHOTOPLETHYSMOGRAPHY;
D O I
10.1155/2019/5363712
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Photoplethysmography (PPG) has been widely used in noninvasive blood volume and blood flow detection since its first appearance. However, its noninvasiveness also makes the PPG signals vulnerable to noise interference and thus exhibits nonlinear and nonstationary characteristics, which have brought difficulties for the denoising of PPG signals. Ensemble empirical mode decomposition known as EEMD, which has made great progress in noise processing, is a noise-assisted nonlinear and nonstationary time series analysis method based on empirical mode decomposition (EMD). The EEMD method solves the "mode mixing" problem in EMD effectively, but it can do nothing about the "end effect," another problem in the decomposition process. In response to this problem, an improved EEMD method based on support vector regression extension (SVR-EEMD) is proposed and verified by simulated data and real-world PPG data. Experiments show that the SVR-EEMD method can solve the "end effect" efficiently to get a better decomposition performance than the traditional EEMD method and bring more benefits to the noise processing of PPG signals.
引用
收藏
页数:10
相关论文
共 44 条
  • [31] A Novel Fault Diagnosis Method for Rolling Bearing Based on EEMD-PE and Multiclass Relevance Vector Machine
    Liu, Xiaodong
    Chen, Yinsheng
    Yang, Jingli
    2017 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2017, : 441 - 446
  • [32] Vital Sign Signal Extraction Method Based on Permutation Entropy and EEMD Algorithm for Ultra-Wideband Radar
    Yang, Degui
    Zhu, Zhengliang
    Liang, Buge
    IEEE ACCESS, 2019, 7 : 178879 - 178890
  • [33] EEMD-Based cICA method for single-channel signal separation and fault feature extraction of gearbox
    Leng, Junfa
    Jing, Shuangxi
    Luo, Chenxu
    Wang, Zhiyang
    JOURNAL OF VIBROENGINEERING, 2017, 19 (08) : 5858 - 5873
  • [34] An EEMD-based method for removing residual blood oxygen signal noise by combining wavelet and singular spectrum analysis
    Xing, Zhiming
    Cao, Yan
    Shan, Xinzhi
    Wang, Lingyu
    Gao, Xiumin
    JOURNAL OF MODERN OPTICS, 2023, 70 (02) : 85 - 99
  • [35] A Rolling Bearing Fault Diagnosis Method Based on EEMD-WSST Signal Reconstruction and Multi-Scale Entropy
    Ge, Jianghua
    Niu, Tianyu
    Xu, Di
    Yin, Guibin
    Wang, Yaping
    ENTROPY, 2020, 22 (03)
  • [36] A Novel Joint Denoising Method for Hydrophone Signal Based on Improved SGMD and WT
    Xing, Tianyu
    Wang, Xiaohao
    Ni, Kai
    Zhou, Qian
    SENSORS, 2024, 24 (04)
  • [37] Empirical mode decomposition based denoising method with support vector regression for time series prediction: A case study for electricity load forecasting
    Yaslan, Yusuf
    Bican, Bahadir
    MEASUREMENT, 2017, 103 : 52 - 61
  • [38] Denoising method of natural gas pipeline leakage signal based on empirical mode decomposition and improved Bhattacharyya distance
    Wang, Dongmei
    Zhu, Lijuan
    Yue, Jikang
    Lu, Jingyi
    Li, Gongfa
    ENGINEERING RESEARCH EXPRESS, 2021, 3 (03):
  • [39] Process method for end effects of Hilbert-Huang transform based on support vector regression machines
    Cheng, Junsheng
    Yu, Dejie
    Yang, Yu
    Jixie Gongcheng Xuebao/Chinese Journal of Mechanical Engineering, 2006, 42 (04): : 23 - 31
  • [40] An Improved VMD-Based Denoising Method for Time Domain Load Signal Combining Wavelet with Singular Spectrum Analysis
    Fu, Jingjing
    Cai, Fuyou
    Guo, Yonghao
    Liu, Hongda
    Niu, Wentie
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2020, 2020