Development and validation of RP-HPLC method for estimation of fisetin in rat plasma

被引:21
|
作者
Kumar, Rajan [1 ]
Kumar, Rakesh [1 ]
Khursheed, Rubiya [1 ]
Awasthi, Ankit [1 ]
Khurana, Navneet [1 ]
Singh, Sachin Kumar [1 ]
Khurana, Shelly [2 ]
Sharma, Neha [1 ]
Gunjal, Pradnya [1 ]
Kaur, Jaskiran [1 ]
Corrie, Leander [1 ]
机构
[1] Lovely Profess Univ, Sch Pharmaceut Sci, Phagwara 144411, Punjab, India
[2] Govt Polytech Coll, Dept Pharm, Amritsar, Punjab, India
关键词
Bioanalytical method; Fisetin; Rat plasma; Recovery; Validation; BIOACTIVE FLAVONOL; PHARMACOKINETICS; IDENTIFICATION; METABOLISM; GERALDOL;
D O I
10.1016/j.sajb.2020.05.010
中图分类号
Q94 [植物学];
学科分类号
071001 ;
摘要
Fisetin is an important phyto-flavonoid that possesses very good anti-oxidant, anti-Parkinson's and anti-cancer activities. A bioanalytical method was developed and validated for the estimation of fisetin in the rat's plasma using reverse phase ultra-fast liquid chromatography combined with a C-18 reverse phase column. Quercetin was used as an internal standard. The mobile phase was composed of acetonitrile and orthophosphoric acid (0.2% v/v) in the ratio of 30:70 v/v. Flow rate was set at 1 mL/min and chromatogram of both compounds was detected at a wavelength of 362 nm. Protein precipitation method was used to extract drug from plasma samples. The retention times for fisetin and quercetin were found at 8.3 min and 16.9 min, respectively. The developed method was found to be linear in the range of 25-125 ng/mL with regression coefficient (r(2)) of 0.9996. The method was validated as per the ICH Q2 (RI) guidelines. The percentage recovery was in the range of 95-105%, which indicated that method was accurate. The percentage relative standard deviation was found to be less than 2% which indicates that method was precised. Limit of detection (LOD) and limit of quantification (LOQ) were found to be 3.18 ng/mL and 9.66 ng/mL, respectively. The developed method was found to be robust as there was no any significant change in response with change in flow rate and composition of mobile phase. Obtained results indicated that the developed method has passed all the validation test parameters and can be applied successfully for estimation of fisetin in the rat plasma. (C) 2020 SAAB. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:284 / 289
页数:6
相关论文
共 50 条
  • [1] DEVELOPMENT AND VALIDATION OF AN RP-HPLC METHOD FOR QUANTITATIVE ESTIMATION OF ILOPERIDONE IN RAT PLASMA
    Dubey, V.
    Saini, T. R.
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2018, 9 (02): : 790 - 794
  • [2] BIOANALYTICAL ESTIMATION OF GLICLAZIDE IN RABBIT PLASMA BY RP-HPLC: METHOD DEVELOPMENT AND VALIDATION
    Rani, Roja B.
    Thaakur, Santhrani
    Rao, S. N. Koteswara G.
    Umasankar, K.
    Reddy, Rajasekhar A.
    Sankar, G. Uma G.
    INTERNATIONAL JOURNAL OF LIFE SCIENCE AND PHARMA RESEARCH, 2020, : 13 - 19
  • [3] Development and validation of RP-HPLC method for estimation of eplerenone in spiked human plasma
    Paraag Gide
    Sandeep Sonawane
    Abhishek Chitnis
    Journal of Pharmaceutical Analysis, 2012, 2 (05) : 390 - 393
  • [4] DEVELOPMENT AND VALIDATION OF A RP-HPLC METHOD FOR THE ESTIMATION OF DAPAGLIFLOZIN IN API
    Sanagapati, Manasa
    Dhanalakshmi, K.
    Nagarjunareddy, G.
    Sreenivasa, S.
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2014, 5 (12): : 5394 - 5397
  • [5] METHOD DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR THE ESTIMATION OF EMPAGLIFLOZIN IN API
    Padmaja, N.
    Veerabhadram, G.
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2016, 7 (02): : 724 - 727
  • [6] Development and Validation of RP-HPLC Method for Simultaneous Estimation of Glibenclamide and Thymoquinone in Rat Plasma and Its Application to Pharmacokinetics
    Ahmad, A.
    Khan, R. M. A.
    Alkharfy, K. M.
    ACTA CHROMATOGRAPHICA, 2015, 27 (03) : 435 - 448
  • [7] Development and validation of RP-HPLC based bioanalytical method for simultaneous estimation of curcumin and quercetin in rat's plasma
    Khursheed, Rubiya
    Wadhwa, Sheetu
    Kumar, Bimlesh
    Gulati, Monica
    Gupta, Saurabh
    Chaitanya, M. V. N. L.
    Kumar, Deepak
    Jha, Niraj Kumar
    Gupta, Gaurav
    Prasher, Parteek
    Chellappan, Dinesh Kumar
    Dua, Kamal
    Singh, Sachin Kumar
    SOUTH AFRICAN JOURNAL OF BOTANY, 2022, 149 : 870 - 877
  • [8] Approaches Development and Validation of RP-HPLC Method for Estimation of Glimepiride in Rat Plasma-Application to Pharmacokinetic Studies
    Tripathi, Alok S.
    Dewani, Anil P.
    Chandewar, Anil V.
    Mazumder, Papiya Mitra
    EURASIAN JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 11 (02): : 55 - 61
  • [9] DEVELOPMENT AND VALIDATION OF A RP-HPLC METHOD FOR THE BIO-ANALYSIS OF OXCARBAZEPINE IN RAT PLASMA
    Anjaneyulu, N.
    Kishore, R. Naga
    Kumar, M. Ravi
    Naik, D. Anil
    INDO AMERICAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2018, 5 (12): : 16786 - 16796
  • [10] BIO ANALYTICAL METHOD DEVELOPMENT AND VALIDATION OF TEMOZOLOMIDE IN RAT PLASMA USING RP-HPLC METHOD
    Pallerla, Swathimutyam
    Prabhakar, Bala
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2016, 7 (03): : 1298 - 1301