Reliability and Responsiveness of Cardiopulmonary Exercise Testing in Fatigued Persons with Multiple Sclerosis and Low to Mild Disability

被引:14
|
作者
Heine, Martin [1 ,2 ,3 ]
van den Akker, Lizanne Eva [4 ,5 ]
Verschuren, Olaf [1 ,2 ,3 ]
Visser-Meily, Anne [1 ,2 ,3 ]
Kwakkel, Gert [6 ,7 ]
机构
[1] Univ Med Ctr Utrecht, Brain Ctr Rudolf Magnus, NL-3583 TM Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Ctr Excellence Rehabil Med, NL-3583 TM Utrecht, Netherlands
[3] Rehabil Ctr Hoogstr, NL-3583 TM Utrecht, Netherlands
[4] Vrije Univ Amsterdam Med Ctr, Dept Rehabil Med, Amsterdam, Netherlands
[5] Vrije Univ Amsterdam Med Ctr, EMGO Inst Hlth & Care Res, Amsterdam, Netherlands
[6] Vrije Univ Amsterdam Med Ctr, MOVE Res Inst Amsterdam, Dept Rehabil Med, Amsterdam, Netherlands
[7] Ctr Rehabil & Rheumatol READE, Dept Neurorehabil, Amsterdam, Netherlands
来源
PLOS ONE | 2015年 / 10卷 / 03期
关键词
UPTAKE EFFICIENCY SLOPE; QUALITY-OF-LIFE; OXYGEN-UPTAKE; FITNESS; VALIDITY; REPRODUCIBILITY; PARAMETERS; AGREEMENT; THERAPY; IMPACT;
D O I
10.1371/journal.pone.0122260
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background Peak oxygen uptake (VO(2)peak) via cardiopulmonary exercise testing is considered the gold standard for testing aerobic capacity in healthy participants and people with various medical conditions. The reliability and responsiveness of cardiopulmonary exercise testing outcomes in persons with MS (PwMS) have not been extensively studied. Objective (1) to investigate the reliability of cardiopulmonary exercise parameters in PwMS; (2) to determine the responsiveness, in terms of the smallest detectable change (SDC), for each parameter. Design Two repeated measurements of cardiopulmonary exercise outcomes were obtained, with a median time interval of 16 days. Methods Thirty-two PwMS suffering from subjective fatigue performed cardiopulmonary exercise tests on a cycle ergometer, to voluntary exhaustion. We calculated the reliability, in terms of the intra-class correlation coefficient (ICC [2, k]; absolute agreement), and the measurement error, in terms of standard error of measurement (SEM) and SDC at individual (SDCindividual) and group level (SDCgroup). Results The ICC for VO(2)peak was 0.951, with an SEM of 0.131 L.min(-1) and an SDCindividual of 0.364 L.min(-1). When corrected for bodyweight, the ICC of VO(2)peak was 0.933, with an SEM of 1.7 mL.kg(-1).min(-1) and in an SDCindividual of 4.6 mL.kg(-1).min(-1). Limitations Generalization of our study results is restricted to fatigued PwMS with a low to mild level of disability. Conclusions At individual level, cardiopulmonary exercise testing can be used reliably to assess physical fitness in terms of VO(2)peak, but less so to determine significant changes. At group level, VO(2)peak can be reliably used to determine physical fitness status and establish change over time.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Comprehensive Profile of Cardiopulmonary Exercise Testing in Ambulatory Persons with Multiple Sclerosis
    Klaren, Rachel E.
    Sandroff, Brian M.
    Fernhall, Bo
    Motl, Robert W.
    SPORTS MEDICINE, 2016, 46 (09) : 1365 - 1379
  • [2] Validity of Maximal Exercise Testing in People With Multiple Sclerosis and Low to Moderate Levels Disability
    Heine, Martin
    Hoogervorst, Erwin L. J.
    Hacking, Hub G. A.
    Verschuren, Olaf
    Kwakkel, Gert
    PHYSICAL THERAPY, 2014, 94 (08): : 1168 - 1175
  • [3] Complexity and pitfalls in maximal exercise testing for persons with multiple sclerosis
    Schlagheck, Marit L.
    Bansi, Jens
    Wenzel, Charlotte
    Kuzdas-Sallaberger, Marina
    Kiesl, David
    Gonzenbach, Roman
    Zimmer, Philipp
    EUROPEAN JOURNAL OF NEUROLOGY, 2023, 30 (09) : 2726 - 2735
  • [4] Cardiopulmonary exercise testing in people with minimally impaired multiple sclerosis
    Apollonatou, Vasiliki
    Lykouras, Dimosthenis
    Kargiotis, Odysseas
    Kasdagli, Maria- Iosifina
    Lagiou, Olga
    Papathanasopoulos, Panagiotis
    Spiropoulos, Konstantinos
    Karkoulias, Kiriakos
    MULTIPLE SCLEROSIS AND RELATED DISORDERS, 2023, 79
  • [5] Disability management and rehabilitation for persons with multiple sclerosis
    Khan, Fary
    Gray, Orla
    NEURAL REGENERATION RESEARCH, 2010, 5 (04) : 301 - 309
  • [6] Feasibility and Safety of Cardiopulmonary Exercise Testing in Multiple Sclerosis: A Systematic Review
    van den Akker, Lizanne Eva
    Heine, Martin
    van der Veldt, Nikki
    Dekker, Joost
    de Groot, Vincent
    Beckerman, Heleen
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2015, 96 (11): : 2055 - 2066
  • [7] Physical Fitness Assessment Across the Disability Spectrum in Persons With Multiple Sclerosis: A Comparison of Testing Modalities
    Pilutti, Lara A.
    Sandroff, Brian M.
    Klaren, Rachel E.
    Learmonth, Yvonne C.
    Platta, Matthew E.
    Hubbard, Elizabeth A.
    Stratton, Michelle
    Motl, Robert W.
    JOURNAL OF NEUROLOGIC PHYSICAL THERAPY, 2015, 39 (04): : 241 - 249
  • [8] Utilization of the Expanded Disability Status Scale as a distinctive instrument for walking impairment in persons with multiple sclerosis with mild disability
    Kahraman, Turhan
    Savci, Sema
    Poyraz, Esra Coskuner
    Ozakbas, Serkan
    Idiman, Egemen
    NEUROREHABILITATION, 2016, 38 (01) : 7 - 14
  • [9] Exercise in the management of persons with multiple sclerosis
    Giesser, Barbara S.
    THERAPEUTIC ADVANCES IN NEUROLOGICAL DISORDERS, 2015, 8 (03) : 123 - 130
  • [10] Multimodal exercise training in multiple sclerosis: A randomized controlled trial in persons with substantial mobility disability
    Sandroff, Brian M.
    Bollaert, Rachel E.
    Pilutti, Lara A.
    Peterson, Melissa L.
    Baynard, Tracy
    Fernhall, Bo
    McAuley, Edward
    Motl, Robert W.
    CONTEMPORARY CLINICAL TRIALS, 2017, 61 : 39 - 47