Optic disk and nerve fiber layer Imaging to detect glaucoma

被引:101
作者
Badala, Federico [1 ]
Nouri-Mahdavi, Kouros [1 ]
Raoof, Duna A. [1 ]
Leeprechanon, Narakorn [1 ]
Law, Simon K. [1 ]
Caprioli, Joseph [1 ]
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Jules Stein Eye Inst, Glaucoma Div, Los Angeles, CA 90095 USA
关键词
D O I
10.1016/j.ajo.2007.07.010
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare optic disk and retinal nerve fiber layer (RNFL) imaging methods to discriminate eyes with early glaucoma from normal eyes. DESIGN: Retrospective, cross-sectional study. METHODS: In a tertiary care academic glaucoma center, 92 eyes of 92 subjects (46 with early perimetric open-angle glaucoma and 46 controls) were studied. Diagnostic performance of optical coherence tomography (StratusOCT; Carl Zeiss Meditec, Dublin, California, USA), scanning laser polarimetry (GDx VCC; Laser Diagnostic Technologies, San Diego, California, USA), confocal laser ophthalmoscopy (Heidelberg Retinal Tomograph [HRT] III; Heidelberg Engineering GmbH, Heidelberg, Germany), and qualitative assessment of stereoscopic optic disk photographs were compared. Outcome measures were areas under receiver operator characteristic curves (AUCs) and sensitivities at fixed specificities. Classification and regression tree (CART) analysis was used to evaluate combinations of quantitative parameters. RESULTS: The average (+/- standard deviation) visual field mean deviation for glaucomatous eyes was -4.0 +/- 2.5 dB (decibels). Parameters with largest AUCs ( standard error) were: average RNFL thickness for StratusOCT (+/- 0.96 +/- 0.02), nerve fiber indicator for GDx VCC (0.92 +/- 0.03), Frederick S. Mikelberg (FSM) discriminant function for HRT III (0.91 +/- 0.03), and 0.97 +/- 0.02 for disk photograph evaluation. At 95% specificity, sensitivity of disk photograph evaluation (90%) was greater than GDx VCC (P = .05) and HRT III (P = .002) results, but not significantly different than those of StratusOCT (P > .05). The combination of StratusOCT average RNFL thickness and HRT III cup,to-disk area with CART produced a sensitivity of 91% and specificity of 96%. CONCLUSIONS: StratusOCT, GDx VCC, and HRT III performed as well as, but not better than, qualitative evaluation of optic disk stereophotographs for detec, tion of early perimetric glaucoma. The combination of StratusOCT average RNFL thickness and HRT III cup-to-disk area ratio provided a high diagnostic precision.
引用
收藏
页码:724 / 732
页数:9
相关论文
共 32 条
  • [11] Evaluation of the glaucomatous damage on retinal nerve fiber layer thickness measured by optical coherence tomography
    Kanamori, A
    Nakamura, M
    Escano, MFT
    Seya, R
    Maeda, H
    Negi, A
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 135 (04) : 513 - 520
  • [12] Kass MA, 2002, ARCH OPHTHALMOL-CHIC, V120, P701
  • [13] MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA
    LANDIS, JR
    KOCH, GG
    [J]. BIOMETRICS, 1977, 33 (01) : 159 - 174
  • [14] Lester M, 1997, OPHTHALMOLOGY, V104, P545
  • [15] LESTER M, 2002, J GLAUCOMA, V11, P97
  • [16] LESTER M, 1997, CAN J OPHTHALMOL, V32, P382
  • [17] LESTER M, 2000, BR J OPHTHALMOL, V84, P464
  • [18] Discrimination between normal and glaucomatous eyes with scanning laser polarimetry and optic disc topography: A preliminary report
    Magacho, L
    Marcondes, AM
    Costa, VP
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2005, 15 (03) : 353 - 359
  • [19] Evaluation of retinal nerve fiber layer, optic nerve head, and macular thickness measurements for glaucoma detection using optical coherence tomography
    Medeiros, FA
    Zangwill, LM
    Bowd, C
    Vessani, RM
    Susanna, R
    Weinreb, RN
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 139 (01) : 44 - 55
  • [20] Comparison of the GDx VCC scanning laser polarimeter, HRT II confocal scanning laser ophthalmoscope, and stratus OCT optical coherence tomograph for the detection of glaucoma
    Medeiros, FA
    Zangwill, LM
    Bowd, C
    Weinreb, RN
    [J]. ARCHIVES OF OPHTHALMOLOGY, 2004, 122 (06) : 827 - 837