3D CT Analysis of Combined Cup and Stem Anteversion in Cases of Cup Navigation in Hip Arthroplasty

被引:13
|
作者
Wassilew, Georgi I. [1 ]
Perka, Carsten [1 ]
Koenig, Christian [2 ]
Janz, Viktor [1 ]
Asbach, Patrick [3 ]
Hasart, Olaf [1 ]
机构
[1] Charite, Dept Orthoped, Ctr Musculoskeletal Surg, D-10117 Berlin, Germany
[2] Charite, Julius Wolff Inst, D-13353 Berlin, Germany
[3] Charite, Dept Radiol, Charite, D-13353 Berlin, Germany
关键词
ACETABULAR COMPONENT; ORIENTATION; DISLOCATION; ALIGNMENT; ACCURACY; POSITION; MOTION; RANGE; FEMUR; WEAR;
D O I
10.3928/01477447-20100510-53
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Navigation of the cup in total hip arthroplasty is well analyzed and shows accurate results, reducing cup outliers of Lewinnek's "safe zone." With regard to the combined anteversion of cup and stem, however, a "new" safe zone with a range of 25 degrees to 50 degrees has been published. The aim of this study was to analyze total anteversion (cup and stem) by postoperative 3D computed tomography in isolated cup navigation cases. In 46 patients, the mean combined anteversion was 34.4 degrees (range, 16.3 degrees-57.3 degrees, SD +/- 9.3 degrees) with 10 outliers. The mean cup anteversion was 19.5 degrees (range, 11 degrees-27 degrees, SD +/- 3.7 degrees). Regarding Lewinnek's "safe zone" (cup only), we observed 5 outliers. An improvement of technique of stem implantation or navigation may reduce outliers of combined anteversion.
引用
收藏
页码:48 / 51
页数:4
相关论文
共 50 条
  • [41] Navigated cup implantation in hip arthroplasty A meta-analysis
    Beckmann, Johannes
    Stengel, Dirk
    Tingart, Markus
    Goetz, Juergen
    Grifka, Joachim
    Luering, Christian
    ACTA ORTHOPAEDICA, 2009, 80 (05) : 538 - 544
  • [42] Trends in cup position utilizing computer-assisted navigation during total hip arthroplasty: A retrospective observational study
    Mays, Rachel R.
    Benson, Jessica R.
    Muir, Jeffrey M.
    Meftah, Morteza
    CURRENT ORTHOPAEDIC PRACTICE, 2020, 31 (03): : 211 - 217
  • [43] Comparison of accuracy of cup position using portable navigation versus alignment guide in total hip arthroplasty in supine position
    Okamoto, Masanori
    Kawasaki, Masashi
    Okura, Toshiaki
    Ochiai, Satoshi
    Yokoi, Hiroyuki
    HIP INTERNATIONAL, 2021, 31 (04) : 492 - 499
  • [44] Could We Expect Postoperative Cup Anteversion after Total Hip Arthroplasty Using Postoperative Plain Anteroposterior and Lateral Radiograph? A Three-Dimensional Experimental Operation Study
    Lee, Tae Sung
    Kwon, Hyuck Min
    Park, Jun Young
    Kim, Dong Ki
    Kang, Kyoung Tak
    Park, Kwan Kyu
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (20)
  • [45] A novel non-invasive mechanical technique of cup and stem placement and leg length adjustment in total hip arthroplasty for dysplastic hips
    Murayama, Takashi
    Ohnishi, Hideo
    Mori, Toshiharu
    Okazaki, Yuichi
    Sujita, Kenji
    Sakai, Akinori
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (06) : 1057 - 1064
  • [46] Increased Cup Anteversion May Not Prevent Posterior Dislocation in Patients With Abnormal Spinopelvic Characteristics in Total Hip Arthroplasty
    Grosso, Matthew J.
    Plaskos, Christopher
    Pierrepont, Jim
    Saxena, Arjun
    ARTHROPLASTY TODAY, 2023, 23
  • [47] Comparing cup placement, leg length, and offset discrepancy after total hip arthroplasty between CT-based robotic arm-assisted and navigation systems
    Shimizu, A.
    Murakami, S.
    Tamai, T.
    Haga, Y.
    Kutsuna, T.
    Kinoshita, T.
    Takao, M.
    BONE & JOINT OPEN, 2025, 6 (01): : 3 - 12
  • [48] Does accelerometer-based portable navigation provide more accurate and precise cup orientation without prosthetic impingement than conventional total hip arthroplasty? A randomized controlled study
    Kiyohara, Masato
    Hamai, Satoshi
    Shiomoto, Kyohei
    Harada, Satoru
    Harada, Tetsunari
    Motomura, Goro
    Ikemura, Satoshi
    Fujii, Masanori
    Kawahara, Shinya
    Nakashima, Yasuharu
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2022, 17 (06) : 1007 - 1015
  • [49] Reliability and accuracy of intraoperative fluoroscopy assessment of acetabular cup anteversion in supine direct anterior approach total hip arthroplasty
    Li, Weihua
    Huang, Yan
    Zou, Zehui
    Liu, Xuqiang
    Li, Xiaofeng
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [50] Comparison of the accuracies of computed tomography-based navigation and image-free navigation for acetabular cup insertion in total hip arthroplasty in the lateral decubitus position
    Hasegawa, Masahiro
    Tone, Shine
    Naito, Yohei
    Wakabayashi, Hiroki
    Sudo, Akihiro
    COMPUTER ASSISTED SURGERY, 2021, 26 (01) : 69 - 76