3D CT Analysis of Combined Cup and Stem Anteversion in Cases of Cup Navigation in Hip Arthroplasty

被引:13
|
作者
Wassilew, Georgi I. [1 ]
Perka, Carsten [1 ]
Koenig, Christian [2 ]
Janz, Viktor [1 ]
Asbach, Patrick [3 ]
Hasart, Olaf [1 ]
机构
[1] Charite, Dept Orthoped, Ctr Musculoskeletal Surg, D-10117 Berlin, Germany
[2] Charite, Julius Wolff Inst, D-13353 Berlin, Germany
[3] Charite, Dept Radiol, Charite, D-13353 Berlin, Germany
关键词
ACETABULAR COMPONENT; ORIENTATION; DISLOCATION; ALIGNMENT; ACCURACY; POSITION; MOTION; RANGE; FEMUR; WEAR;
D O I
10.3928/01477447-20100510-53
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Navigation of the cup in total hip arthroplasty is well analyzed and shows accurate results, reducing cup outliers of Lewinnek's "safe zone." With regard to the combined anteversion of cup and stem, however, a "new" safe zone with a range of 25 degrees to 50 degrees has been published. The aim of this study was to analyze total anteversion (cup and stem) by postoperative 3D computed tomography in isolated cup navigation cases. In 46 patients, the mean combined anteversion was 34.4 degrees (range, 16.3 degrees-57.3 degrees, SD +/- 9.3 degrees) with 10 outliers. The mean cup anteversion was 19.5 degrees (range, 11 degrees-27 degrees, SD +/- 3.7 degrees). Regarding Lewinnek's "safe zone" (cup only), we observed 5 outliers. An improvement of technique of stem implantation or navigation may reduce outliers of combined anteversion.
引用
收藏
页码:48 / 51
页数:4
相关论文
共 50 条
  • [21] Rigid fixation of pelvic tracker essential for accurate cup placement in CT-based navigation total hip arthroplasty
    Hamawaki, Makoto
    Hamada, Hidetoshi
    Uemura, Keisuke
    Takashima, Kazuma
    Mae, Hirokazu
    Nakamura, Nobuo
    Sugano, Nobuhiko
    JOURNAL OF ARTIFICIAL ORGANS, 2024, 27 (04) : 403 - 409
  • [22] Validation of navigation assisted cup placement in total hip arthroplasty
    M. Ajith Kumar
    M. Shantharam Shetty
    Kanthi G. Kiran
    Abhishek R. Kini
    International Orthopaedics, 2012, 36 : 17 - 22
  • [23] Which one is more affected by navigation-assisted cup positioning in total hip arthroplasty: Anteversion or inclination? A retrospective matched-pair cohort study in Asian physique
    Oh, Kwang Jun
    Kim, Byung Kag
    Jo, Myung Il
    Ahn, Byung Mun
    JOURNAL OF ORTHOPAEDIC SURGERY, 2018, 26 (02):
  • [24] 3D Printed Patient-Specific Acetabular Jig for Cup Placement in Total Hip Arthroplasty
    Mishra, Abhishek
    Verma, Tarun
    Rajkumar
    Agarwal, Gaurang
    Sharma, Amit
    Maini, Lalit
    INDIAN JOURNAL OF ORTHOPAEDICS, 2020, 54 (02) : 174 - 180
  • [25] Revision Total Hip Arthroplasty Using Imageless Navigation With the Concept of Combined Anteversion
    Chang, Jun-Dong
    Kim, In-Sung
    Prabhakar, Sharad
    Mansukhani, Sameer A.
    Lee, Sang-Soo
    Yoo, Je-Hyun
    JOURNAL OF ARTHROPLASTY, 2017, 32 (05) : 1576 - 1580
  • [26] Enhancing the accuracy of cup placement in total hip arthroplasty using CT-based navigation by a trainee surgeon: a retrospective cohort study
    Tachibana, Tetsuya
    Katagiri, Hiroki
    Ogawa, Takahisa
    Koyano, Gaku
    Jinno, Tetsuya
    BMC MUSCULOSKELETAL DISORDERS, 2025, 26 (01)
  • [27] Non-equivalent Results from Different Anteversion Measurements Methods for the Evaluation of the Acetabular Cup Orientation in Total Hip Arthroplasty
    Snijders, Thom E.
    Schlosser, Tom P. C.
    van Gaalen, Steven M.
    Castelein, Rene M.
    Weinans, Harry
    de Gast, Arthur
    ORTHOPAEDIC SURGERY, 2019, 11 (02) : 241 - 247
  • [28] Precision of Cup Positioning Using a Novel Computed Tomography Based Navigation System in Total Hip Arthroplasty
    Nemati, Hassan M.
    Christensson, Albin
    Pettersson, Andreas
    Nemeth, Gunnar
    Flivik, Gunnar
    MEDICINA-LITHUANIA, 2024, 60 (10):
  • [29] The Accuracy of Acetabular Cup Positioning Using Patient-Specific 3D Orientation Guidance in Total Hip Arthroplasty
    McMahon, Stephen J.
    Christmas, Maxim U. S., I
    McMahon, Jack
    Pierrepont, Jim
    McMahon, Ryan
    SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH, 2020, 36
  • [30] Is transverse acetabular ligament a reliable guide for aligning cup anteversion in total hip arthroplasty?: A measurement by CT arthrography in 90 hips
    Yoon, Byung-Ho
    Ha, Yong-Chan
    Lee, Young-Kyun
    Jo, Woo-Lam
    Lee, Kyoung-Min
    Koo, Kyung-Hoi
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2016, 21 (02) : 199 - 204