Simultaneous extraction/derivatization for the analysis of sulfite by capillary electrophoresis: A high-throughput reference method to meet the demand of seafood inspection

被引:8
作者
Goncalves, Samantha [1 ,2 ,3 ]
Molognoni, Luciano [2 ,3 ]
Daguer, Heitor [2 ]
Pimenta, Ricardo [2 ]
Hoff, Rodrigo Barcellos [2 ]
Micke, Gustavo Amadeu [1 ]
Vitali, Luciano [1 ]
机构
[1] Univ Fed Santa Catarina UFSC, Dept Quim, Programa Posgrad Quim, Florianopolis, SC, Brazil
[2] Minist Agr Pecuaria & Abastecimento MAPA, Secao Lab Avancada, Lab Fed Def Agr, Sao Jose, SC, Brazil
[3] Inst Catarinense Sanidade Agr, Florianopolis, SC, Brazil
关键词
Sulfite; Capillary zone electrophoresis; Food analysis; Derivatization; Preservatives; Shrimp; REVERSIBLY BOUND SULFITE; ZONE-ELECTROPHORESIS; SULFUR SPECIATION; CHROMATOGRAPHY; STABILIZATION; THIOSULFATE; SULFATE; SAMPLES; FOODS;
D O I
10.1016/j.foodres.2022.111780
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Sulfite is widely used to prevent enzymatic browning in shrimp and lobster processing. However, sulfite may cause allergy in sensitive consumers. Thus, regulatory agencies set limits for its use. Sulfite is usually controlled by the normalized Monier-Williams (MW) titrimetric method that allows a limited number of samples to be analyzed. This manuscript consolidates an innovative method for sulfite inspection in seafood by capillary zone electrophoresis with diode array detector (CZE-DAD). A simple, fast, and simultaneous extraction and deriva-tization method was developed to provide high throughput for analytical routine. The high instability of the sulfite was suppressed by its derivatization with formaldehyde producing hydroxymethylsulfonate. The evalu-ation of its analytical performance yielded excellent results in compliance with the strict parameters required for metrological accreditation. The CZE-DAD method was selective and specific when submitted to confirmatory evaluations by liquid chromatography coupled to mass spectrometry. The limit of detection (3.50 mg kg(-1)), limit of quantitation (11.7 mg kg( -1)) and recoveries (99-103%) were adequate for sample analysis. The measurement uncertainty was estimated by the propagation of errors and experimental standard uncertainties (precision, accuracy, and analytical curves) and type B uncertainties from traceable measurement instruments. The low relative uncertainty (10%) and the adequate reproducibility demonstrated method suitability. The CZE-DAD results were compared to the MW method through the respective expanded standard uncertainties and normalized error. This new method is promising to be used in seafood inspection and continuous laboratory evaluations using instrumentation not very expensive to acquire and maintain.
引用
收藏
页数:9
相关论文
共 27 条
  • [1] AOAC, 1990, Official Methods of Analysis
  • [2] Brasil, 2020, INS NAC METR NORM QU
  • [3] Determination of Sulfite in Food by Liquid Chromatography Tandem Mass Spectrometry: Collaborative Study
    Carlos, Katherine S.
    de Jager, Lowri S.
    [J]. JOURNAL OF AOAC INTERNATIONAL, 2017, 100 (06) : 1785 - 1794
  • [4] ChemAxon, 2022, CHEMICALIZE
  • [5] COLLINSWILLIAMS C, 1983, ANN ALLERGY, V51, P315
  • [6] Determination of sorbate and benzoate in beverage samples by capillary electrophoresis - Optimization of the method with inspection of ionic mobilities
    Costa, Ana Carolina O.
    Perfeito, Lisliane da Silva
    Tavares, Marina F. M.
    Micke, Gustavo A.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2008, 1204 (01) : 123 - 127
  • [7] Sulfur speciation by capillary zone electrophoresis: conditions for sulfite stabilization and determination in the presence of sulfate, thiosulfate and peroxodisulfate
    de Carvalho, LM
    Schwedt, G
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 368 (2-3): : 208 - 213
  • [8] Sulfur speciation by capillary zone electrophoresis determination of dithionite and its decomposition products sulfite, sulfate and thiosulfate in commercial bleaching agents
    de Carvalho, LM
    Schwedt, G
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2005, 1099 (1-2) : 185 - 190
  • [9] A fast method for simultaneous analysis of methyl, ethyl, propyl and butylparaben in cosmetics and pharmaceutical formulations using capillary zone electrophoresis with UV detection
    Dolzan, Maressa D.
    Spudeit, Daniel Alfonso
    Azevedo, Monia Stremel
    Costa, Ana Carolina O.
    Leal de Oliveira, Marcone Augusto
    Micke, Gustavo Amadeu
    [J]. ANALYTICAL METHODS, 2013, 5 (21) : 6023 - 6029
  • [10] FDA (United States Food and Drug Administration), 2022, FISH FISHERY PRODUCT