Vitamin E-blended highly cross-linked polyethylene liners in total hip arthroplasty: a randomized, multicenter trial using virtual CAD-based wear analysis at 5-year follow-up

被引:19
作者
Busch, Andre [1 ]
Jaeger, Marcus [1 ]
Klebingat, Stefan [2 ]
Baghdadi, Josef [3 ]
Floerkemeier, Thilo [4 ]
Huetter, Felix [5 ]
Grupp, Thomas M. [6 ,7 ]
Haversath, Marcel [1 ]
机构
[1] Univ Duisburg Essen, Dept Orthopaed Trauma & Reconstruct Surg, Marienhosp Mulheim Ruhr, Chair Orthopaed & Trauma Surg, Essen, Germany
[2] Otto von Guericke Univ, Inst Med Tech & Forsch Campus STIMULATE, Magdeburg, Germany
[3] Hannover Med Sch, Dept Orthopaed Surg, Hannover, Germany
[4] Univ Klinikum Halle Saale, Dept Orthopadie Unfall & Wiederherstellungschirur, Ernst Grube Str 40, D-06114 Halle, Saale, Germany
[5] Elisabeth Klinikum Olsberg, Dept Orthopaed & Trauma Surg, Olsberg, Germany
[6] Aesculap AG, Res & Dev, D-78532 Tuttlingen, Germany
[7] Ludwig Maximilians Univ Munchen, Dept Orthopaed Surg Phys Med & Rehabil, Campus Grosshadern, Munich, Germany
关键词
Total hip arthroplasty; CAD-based wear analysis; UHMWPE-XE; Particle-induced osteolysis; MOLECULAR-WEIGHT POLYETHYLENE; FEMORAL-HEAD-PENETRATION; ALPHA-TOCOPHEROL; RADIOSTEREOMETRIC ANALYSIS; PRIMARY STABILITY; ACETABULAR CUPS; RESISTANCE; ACCURACY; IRRADIATION; CEMENTLESS;
D O I
10.1007/s00402-020-03358-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Progressive oxidation of highly cross-linked ultra-high molecular weight (UHMPWE-X) liners is considered to be a risk factor for material failure in THA. Antioxidants such as vitamin E (alpha-tocopherol) (UHMWPE-XE) were supplemented into the latest generation of polyethylene liners. To prevent inhomogenous vitamin E distribution within the polymer, blending was established as an alternative manufacturing process to diffusion. The purpose of the present study was to investigate the in vivo wear behavior of UHMWPE-XE in comparison with conventional UHMWPE-X liners using virtual CAD-based radiographs. Methods Until now, 94 patients from a prospective, randomized, controlled, multicenter study were reviewed at 5-year follow-up. Of these, 51 (54%) received UHMWPE-XE and 43 (46%) UHMWPE-X liners. Anteroposterior pelvic radiographs were made immediately after surgery and at 1 and 5 years postoperatively. The radiographs were analyzed using the observer-independent analysis software RayMatch(R) (Raylytic GmbH, Leipzig, Germany). Results The mean wear rate was measured to be 23.6 mu m/year (SD 13.7; range 0.7-71.8 mu m). There were no significant differences between the two cohorts (UHMWPE-X: 23.2 mu m/year vs. UHMWPE-XE: 24.0 mu m/year, p = 0.73). Cup anteversion significantly changed within the 1st year after implantation independent from the type of polyethylene liner [UHMWPE-X: 18.2-23.9 degrees (p = 0.0001); UHMWPE-XE: 21.0-25.5 degrees (p = 0.002)]. No further significant changes of cup anteversion in both groups were found between year 1 and 5 after implantation [UHMWPE-X (p = 0.46); UHMWPE-XE (p = 0.56)]. Conclusion The present study demonstrates that the addition of vitamin E does not adversely affect the midterm wear behavior of UHMWPE-X. The antioxidative benefit of vitamin E is expected to become evident in long-term follow-up. Cup anteversion increment by 5 degrees within the 1st year is likely a result of the released hip flexion contracture resulting in an enhanced posterior pelvic tilt. Therefore, a reassessment of target values in acetabular cup placement might be considered.
引用
收藏
页码:1859 / 1866
页数:8
相关论文
共 44 条
  • [1] Radiostereometric Analysis Study of Tantalum Compared with Titanium Acetabular Cups and Highly Cross-Linked Compared with Conventional Liners in Young Patients Undergoing Total Hip Replacement
    Ayers, David C.
    Greene, Meridith
    Snyder, Benjamin
    Aubin, Michelle
    Drew, Jacob
    Bragdon, Charles
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2015, 97A (08) : 627 - 634
  • [2] Beaulé PE, 2001, CLIN ORTHOP RELAT R, P159
  • [3] Comparison of the Primary Stability of a Porous Coated Acetabular Revision Cup With a Standard Cup
    Beckmann, Nicholas A.
    Jaeger, Sebastian
    Janoszka, Maciej B.
    Klotz, Matthias C.
    Bruckner, Thomas
    Bitsch, Rudi G.
    [J]. JOURNAL OF ARTHROPLASTY, 2018, 33 (02) : 580 - 585
  • [4] Accuracy of EBRA-FCA in the measurement of migration of femoral components of total hip replacement
    Biedermann, R
    Krismer, M
    Stöckl, B
    Mayrhofer, P
    Ornstein, E
    Franzén, H
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (02): : 266 - 272
  • [5] Bottner F, 2005, HSS J, V1, P94, DOI 10.1007/s11420-005-0114-2
  • [6] Vitamin E-stabilized UHMWPE for Total Joint Implants: A Review
    Bracco, Pierangiola
    Oral, Ebru
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (08) : 2286 - 2293
  • [7] Accuracy of methods to measure femoral head penetration within metal-backed acetabular components
    Callary, Stuart A.
    Solomon, Lucian B.
    Holubowycz, Oksana T.
    Campbell, David G.
    Howie, Donald W.
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2017, 35 (05) : 988 - 996
  • [8] The Otto Aufranc Award -: Highly cross-linked polyethylene in Total Hip Arthroplasty -: Randomized evaluation of penetration rate in cemented and uncemented sockets using radiostereometric analysis
    Digas, G
    Kärrholm, J
    Thanner, J
    Malchau, H
    Herberts, P
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (429) : 6 - 16
  • [9] Characterization of long-term femoral-head-penetration rates - Association with and prediction of osteolysis
    Dowd, JE
    Sychterz, CJ
    Young, AM
    Engh, CA
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (08) : 1102 - 1107
  • [10] Evaluation of in vivo wear of vitamin E-diffused highly crosslinked polyethylene at five years A MULTICENTRE RADIOSTEREOMETRIC ANALYSIS STUDY
    Galea, V. P.
    Connelly, J. W.
    Shareghi, B.
    Karrholm, J.
    Skoldenberg, O.
    Salemyr, M.
    Laursen, M. B.
    Muratoglu, O.
    Bragdon, C.
    Malchau, H.
    [J]. BONE & JOINT JOURNAL, 2018, 100B (12) : 1592 - 1599