Analysis of dose characteristics from beveled and flat applicators in intra-operative radiation therapy (IORT) using Monte Carlo simulation, Wellhofer measurement and film dosimetry

被引:0
|
作者
Parsai, E [1 ]
Li, J [1 ]
Feldmeier, J [1 ]
Schifter, D [1 ]
Priyadershi, A [1 ]
Dobelbower, R [1 ]
机构
[1] Med Coll Ohio, Toledo, OH 43699 USA
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:1420 / 1420
页数:1
相关论文
共 19 条
  • [1] A Monte Carlo study of dosimetric characteristics of intra-operative radiation therapy (IORT) electron beam with beveled applicators
    Li, J
    Parsai, E
    Lee, S
    Feldmeier, J
    MEDICAL PHYSICS, 2003, 30 (06) : 1515 - 1515
  • [2] Optimized Monte-Carlo intra-operative radiotherapy dose prediction for flat and surface applicators
    Vidal, M.
    Ibanez, P.
    Parent, L.
    Goubert, M.
    Ferrand, R.
    Guerra, P.
    Udias, J. M.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S277 - S278
  • [3] Intra-operative radiation therapy optimization using the Monte Carlo method
    Rosetti, M
    Benassi, M
    Bruzzaniti, V
    Bufacchi, A
    D'Andrea, M
    ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 455 - 460
  • [4] Output Factor Measurement of a Dedicated Intra-Operative Radiotherapy (IORT) Accelerator Using Ethanol Chlorobenzene (ECB) Dosimeter and Comparing the Results with Ionometric Dosimetry and Monte Carlo Simulation
    Barzegar, Mojtaba
    Shirazi, Ali Reza
    Mahdavi, Seyed Rabi
    Baghani, Hamid Reza
    IRANIAN JOURNAL OF RADIOLOGY, 2017, 14 (02)
  • [5] MONTE CARLO SIMULATIONS TO IMPROVE INTRA-OPERATIVE RADIATION THERAPY DOSE CALCULATIONS IN CLINICAL SETTING
    Strigari, L.
    Iaccarino, G.
    D'Andrea, M.
    Bellesi, L.
    Felici, G.
    Ciccotelli, A.
    Benassi, M.
    Soriani, A.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S13 - S14
  • [6] MONTE CARLO SIMULATION OF THE ELECTRON BEAMS PRODUCED BY A LINEAR ACCELERATOR FOR INTRA-OPERATIVE RADIATION THERAPY
    Mihailescu, D.
    Borcia, C.
    ROMANIAN REPORTS IN PHYSICS, 2014, 66 (01) : 61 - 74
  • [7] Evaluation of heterogeneity effect in intra-operative HDR (IOHDR) brachytherapy dose calculation using Monte Carlo simulation and GAFCHROMIC EBT film measurement
    Le, Y.
    Armour, E.
    Wong, J.
    MEDICAL PHYSICS, 2007, 34 (06) : 2450 - 2450
  • [8] Hybrid Monte Carlo dose algorithm for low energy X-rays intra-operative radiation therapy
    Vidal, M.
    Ibanez, P.
    Cal Gonzalez, J.
    Guerra, P.
    Udias, J. M.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S106 - S107
  • [9] Intrabeam Post-Operative Monte Carlo Heterogeneous Treatment Planning for Breast Intra-Operative Radiation Treatments (IORT) Using a Pre-Operative CT Scan
    Trichter, S.
    Balogun, O.
    Ng, J.
    Swistel, A.
    Nowak, F.
    Kulidzhanov, F.
    DeWyngaert, K.
    MEDICAL PHYSICS, 2018, 45 (06) : E128 - E128
  • [10] Monte Carlo evaluation of the effect of inhomogeneities on dose calculation for low energy photons intra-operative radiation therapy in pelvic area
    Chiavassa, Sophie
    Buge, Francois
    Herve, Chloe
    Delpon, Gregory
    Rigaud, Jerome
    Lisbona, Albert
    Supiot, Sthephane
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (08): : 956 - 962