Natively fat-suppressed 5D whole-heart MRI with a radial free-running fast-interrupted steady-state (FISS) sequence at 1.5T and 3T

被引:29
作者
Bastiaansen, Jessica A. M. [1 ,2 ]
Piccini, Davide [1 ,2 ,3 ]
Di Sopra, Lorenzo [1 ,2 ]
Roy, Christopher W. [1 ,2 ]
Heerfordt, John [1 ,2 ,3 ]
Edelman, Robert R. [4 ,5 ]
Koktzoglou, Ioannis [4 ,6 ]
Yerly, Jerome [1 ,2 ,7 ]
Stuber, Matthias [1 ,2 ,7 ]
机构
[1] Lausanne Univ Hosp, Dept Diagnost & Intervent Radiol, Lausanne, Switzerland
[2] Univ Lausanne, Lausanne, Switzerland
[3] Siemens Healthcare AG, Adv Clin Imaging Technol, Lausanne, Switzerland
[4] NorthShore Univ HealthSyst, Dept Radiol, Evanston, IL USA
[5] Northwestern Univ, Feinberg Sch Med, Chicago, IL 60611 USA
[6] Univ Chicago, Pritzker Sch Med, Chicago, IL 60637 USA
[7] Ctr Biomed Imaging, Lausanne, Switzerland
基金
瑞士国家科学基金会; 美国国家卫生研究院;
关键词
1; 5T MRI; 3T MRI; bSSFP; compressed sensing; fat suppression; FISS; free-running; noncontrast; 3D radial; whole-heart MRI; VISUALIZATION;
D O I
10.1002/mrm.27942
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To implement, optimize, and test fast interrupted steady-state (FISS) for natively fat-suppressed free-running 5D whole-heart MRI at 1.5 tesla (T) and 3T. Methods FISS was implemented for fully self-gated free-running cardiac- and respiratory-motion-resolved radial imaging of the heart at 1.5T and 3T. Numerical simulations and phantom scans were performed to compare fat suppression characteristics and to determine parameter ranges (number of readouts [NR] per FISS module and TR) for effective fat suppression. Subsequently, free-running FISS data were collected in 10 healthy volunteers and images were reconstructed with compressed sensing. All acquisitions were compared with a continuous balanced steady-state free precession version of the same sequence, and both fat suppression and scan times were analyzed. Results Simulations demonstrate a variable width and location of suppression bands in FISS that were dependent on TR and NR. For a fat suppression bandwidth of 100 Hz and NR <= 8, simulations demonstrated that a TR between 2.2 ms and 3.0 ms is required at 1.5T, whereas a range of 3.0 ms to 3.5 ms applies at 3T. Fat signal increases with NR. These findings were corroborated in phantom experiments. In volunteers, fat SNR was significantly decreased using FISS compared with balanced steady-state free precession (P < 0.05) at both field strengths. After protocol optimization, high-resolution (1.1 mm(3)) 5D whole-heart free-running FISS can be performed with effective fat suppression in under 8 min at 1.5T and 3T at a modest scan time increase compared to balanced steady-state free precession. Conclusion An optimal FISS parameter range was determined enabling natively fat-suppressed 5D whole-heart free-running MRI with a single continuous scan at 1.5T and 3T, demonstrating potential for cardiac imaging and noncontrast angiography.
引用
收藏
页码:45 / 55
页数:11
相关论文
共 20 条
[1]  
Bacher M, 2018, P 26 ANN M ISMRM PAR, P4798
[2]   Noncontrast free-breathing respiratory self-navigated coronary artery cardiovascular magnetic resonance angiography at 3T using lipid insensitive binomial off-resonant excitation (LIBRE) [J].
Bastiaansen, Jessica A. M. ;
van Heeswijk, Ruud B. ;
Stuber, Matthias ;
Piccini, Davide .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2019, 21 (1)
[3]   Flexible water excitation for fat-free MRI at 3T using lipid insensitive binomial off-resonant RF excitation (LIBRE) pulses [J].
Bastiaansen, Jessica A. M. ;
Stuber, Matthias .
MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (06) :3007-3017
[4]   Simultaneous fat-free isotropic 3D anatomical imaging and T2 mapping of knee cartilage with lipid-insensitive binomial off-resonant RF excitation (LIBRE) pulses [J].
Colotti, Roberto ;
Omoumi, Patrick ;
van Heeswijk, Ruud B. ;
Bastiaansen, Jessica A. M. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 49 (05) :1275-1284
[5]   Free-running 4D whole-heart self-navigated golden angle MRI: Initial results [J].
Coppo, Simone ;
Piccini, Davide ;
Bonanno, Gabriele ;
Chaptinel, Jerome ;
Vincenti, Gabriella ;
Feliciano, Helene ;
van Heeswijk, Ruud B. ;
Schwitter, Juerg ;
Stuber, Matthias .
MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (05) :1306-1316
[6]  
Di Sopra L., 2017, P INT SOC MAG RESON, V25, P3148
[7]   An automated approach to fully self-gated free-running cardiac and respiratory motion-resolved 5D whole-heart MRI [J].
Di Sopra, Lorenzo ;
Piccini, Davide ;
Coppo, Simone ;
Stuber, Matthias ;
Yerly, Jerome .
MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (06) :2118-2132
[8]   Cardiovascular cine imaging and flow evaluation using Fast Interrupted Steady-State (FISS) magnetic resonance [J].
Edelman, Robert R. ;
Serhal, Ali ;
Pursnani, Amit ;
Pang, Jianing ;
Koktzoglou, Ioannis .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2018, 20
[9]   Soap-bubble visualization and quantitative analysis of 3D coronary magnetic resonance angiograms [J].
Etienne, A ;
Botnar, RM ;
van Muiswinkel, AMC ;
Boesiger, P ;
Manning, WJ ;
Stuber, M .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (04) :658-666
[10]   5D whole-heart sparse MRI [J].
Feng, Li ;
Coppo, Simone ;
Piccini, Davide ;
Yerly, Jerome ;
Lim, Ruth P. ;
Masci, Pier Giorgio ;
Stuber, Matthias ;
Sodickson, Daniel K. ;
Otazo, Ricardo .