The burden of the variability introduced by the HEp-2 assay kit and the CAD system in ANA indirect immunofluorescence test

被引:25
作者
Infantino, M. [1 ]
Meacci, F. [1 ]
Grossi, V. [1 ]
Manfredi, M. [1 ]
Benucci, M. [2 ]
Merone, M. [3 ]
Soda, P. [3 ]
机构
[1] S Giovanni di Dio Hosp, Immunol & Allergy Lab, Via Torregalli 3, I-50143 Florence, Italy
[2] S Giovanni di Dio Hosp, Rheumatol Unit, Via Torregalli 3, I-50143 Florence, Italy
[3] Univ Campus Biomed, Dept Engn, Comp Syst & Bioinformat Lab, Rome, Italy
关键词
Indirect immunofluorescence; HEp-2; Antinuclear antibodies; Automated classification system; Standardization; ANTINUCLEAR ANTIBODIES; AUTOANTIBODIES; GUIDELINES; DIAGNOSIS; IMMUNOASSAYS; CHALLENGES;
D O I
10.1007/s12026-016-8845-3
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
According to the recent recommendations of the American College of Rheumatology, ANATask Force, IIF technique should be considered the gold standard in antinuclear antibodies (ANAs) testing. To overcome the lack of standardization, biomedical industries have developed several computer-aided diagnosis (CAD) systems. Two hundred and sixty-one consecutive samples with suspected autoimmune diseases were tested for ANA by means of IIF on routinely HEp-2 assay kit (Euroimmun AG). Assignment of result wasmade if consensus for positive/negative was reached by at least 2 out of 3 expert physicians. ANAIIF was also carried out using 3 CAD systems: Zenit G-Sight (n = 84), Helios (n = 85) and NOVA View (n = 92); human evaluation was repeated on the same substrate of each CAD system (Immco, Aesku and Inova HEp-2 cells, respectively). To anonymize the results, we randomly named these three systems as A, B and C. We ran a statistical analysis computing several measures of agreement between the ratings, and we also improved the evaluation by using the Wilcoxon's test for nonparametric data. Agreement between the human readings on routinely HEp-2 assay kit and human readings on CAD HEp-2 assay was substantial for A (k = 0.82) and B (k = 0.72), and almost perfect for C (k = 0.89). Such readingswere statistically different only in case A. Comparing experts' readings with the readings of CAD systems, when the samples were prepared using CAD HEp-2 assay kits, we found almost perfect agreement for B and C (k = 0.86; k = 0.82) and substantial agreement for A (k = 0.73). Again, human and CAD readings were statistically different only in A. When we compared the readings of medical experts on routinely HEp-2 assay kit with the output of the CAD systems thatworked using their own slides, we found substantial agreement for all the systems (A: k = 0.62; B: k = 0.65; C: k = 0.71). Such readingswere not statistically different. The change of the assay kit and/or the introduction of a CAD system affect the laboratory reporting, with an evident impact on the autoimmune laboratory workflow. The CAD systems may represent one of themost important novel elements of harmonization in the autoimmunity field, reducing intra-and inter-laboratory variability in a new vision of the diagnostic autoimmune platform.
引用
收藏
页码:345 / 354
页数:10
相关论文
共 59 条
[1]  
[Anonymous], 2006, AUTOANTIBODIES AUTOI
[2]  
[Anonymous], REUMATISMO
[3]  
[Anonymous], 2006, ILA2A2 CLSI
[4]  
[Anonymous], INT J STAT MED RES
[5]   Screening of antinuclear antibodies: comparison between enzyme immunoassay based on nuclear homogenates, purified or recombinant antigens and immunofluorescence assay [J].
Bernardini, S ;
Infantino, M ;
Bellincampi, L ;
Nuccetelli, M ;
Afeltra, A ;
Iori, R ;
Biroccio, A ;
Urbani, A ;
Federici, G .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2004, 42 (10) :1155-1160
[6]   Original Approach for Automated Quantification of Antinuclear Autoantibodies by Indirect Immunofluorescence [J].
Bertin, Daniel ;
Jourde-Chiche, Noemie ;
Bongrand, Pierre ;
Bardin, Nathalie .
CLINICAL & DEVELOPMENTAL IMMUNOLOGY, 2013,
[7]   Variability between methods to determine ANA, anti-dsDNA and anti-ENA autoantibodies: a collaborative study with the biomedical industry [J].
Bizzaro, N ;
Tozzoli, R ;
Tonutti, E ;
Piazza, A ;
Manoni, F ;
Ghirardello, A ;
Bassetti, D ;
Villalta, D ;
Pradella, M ;
Rizzotti, P .
JOURNAL OF IMMUNOLOGICAL METHODS, 1998, 219 (1-2) :99-107
[8]   Automated antinuclear immunofluorescence antibody screening: A comparative study of six computer-aided diagnostic systems [J].
Bizzaro, Nicola ;
Antico, Antonio ;
Platzgummer, Stefan ;
Tonutti, Elio ;
Bassetti, Danila ;
Pesente, Fiorenza ;
Tozzoli, Renato ;
Tampoia, Marilina ;
Villalta, Danilo .
AUTOIMMUNITY REVIEWS, 2014, 13 (03) :292-298
[9]   Automated indirect immunofluorescence antinuclear antibody analysis is a standardized alternative for visual microscope interpretation [J].
Bonroy, Carolien ;
Verfaillie, Charlotte ;
Smith, Vanessa ;
Persijn, Lies ;
De Witte, Evy ;
De Keyser, Filip ;
Devreese, Katrien .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2013, 51 (09) :1771-+
[10]   Detection of antinuclear antibodies by automated indirect immunofluorescence analysis [J].
Bossuyt, Xavier ;
Cooreman, Sarah ;
De Baere, Heidi ;
Verschueren, Patrick ;
Westhovens, Rene ;
Blockmans, Daniel ;
Marien, Godelieve .
CLINICA CHIMICA ACTA, 2013, 415 :101-106