Radiation exposure from fluoroscopy during fixation of hip fracture and fracture of ankle: Effect of surgical experience

被引:32
作者
Botchu, Rajesh [1 ]
Ravikumar, Kassetti [1 ]
机构
[1] Maidstone Hlth Author, Dept Orthopaed, Maidstone, Kent, England
关键词
Experience; fixation; fracture; radiation; surgeon;
D O I
10.4103/0019-5413.43398
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Over the years, there has been a tremendous increase in the use of fluoroscopy in orthopaedics. The risk of contracting cancer is significantly higher for an orthopedic surgeon. Hip and spine surgeries account for 99 of the total radiation dose. The amount of radiation to patients and operating surgeon depends on the position of the patient and the type of protection used during the surgery. A retrospective study to assess the influence of the radiation exposure of the operating surgeon during fluoroscopically assisted fixation of fractures of neck of femur (dynamic hip screw) and ankle (Weber B) was performed at a district general hospital in the United Kingdom. Materials and Methods: Sixty patients with undisplaced intertrochanteric fracture were included in the hip group, and 60 patients with isolated fracture of lateral malleolus without communition were included in the ankle group. The hip and ankle groups were further divided into subgroups of 20 patients each depending on the operative experience of the operating surgeon. All patients had fluoroscopically assisted fixation of fracture by the same approach and technique. The radiation dose and screening time of each group were recorded and analyzed. Results: The radiation dose and screening time during fluoroscopically assisted fixation of fracture neck of femur were significantly high with surgeons and trainees with less than 3 years of surgical experience in comparison with surgeons with more than 10 years of experience. The radiation dose and screening time during fluoroscopically assisted fixation of Weber B fracture of ankle were relatively independent of operating surgeons surgical experience. Conclusion: The experience of operating surgeon is one of the important factors affecting screening time and radiation dose during fluoroscopically assisted fixation of fracture neck of femur. The use of snapshot pulsed fluoroscopy and involvement of senior surgeons could significantly reduce the radiation dose and screening time.
引用
收藏
页码:471 / 473
页数:3
相关论文
共 9 条
[1]  
BARRY TP, 1984, CLIN ORTHOP RELAT R, P160
[2]   Dose-area product measurements in a range of common orthopaedic procedures and their possible use in establishing local diagnostic reference levels [J].
Crawley, MT ;
Rogers, AT .
BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (871) :740-744
[3]   Ionising radiation during internal fixation of extracapsular neck of femur fractures [J].
Giannoudis, PV ;
McGuigan, J ;
Shaw, DL .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1998, 29 (06) :469-472
[4]   Increased cancer risk among surgeons in an orthopaedic hospital [J].
Mastrangelo, G ;
Fedeli, U ;
Fadda, E ;
Giovanazzi, A ;
Scoizzato, L ;
Saia, B .
OCCUPATIONAL MEDICINE-OXFORD, 2005, 55 (06) :498-500
[5]   Radiation exposure to the orthopaedic surgical team during fluoroscopy: "How far away is far enough?" [J].
Mehlman, CT ;
DiPasquale, TG .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1997, 11 (06) :392-398
[6]  
ORourke PJ, 1996, J ROY COLL SURG EDIN, V41, P40
[7]  
SMITH GL, 1992, ANN ROY COLL SURG, V74, P326
[8]   Occupational exposure from common fluoroscopic projections used in orthopaedic surgery [J].
Theocharopoulos, N ;
Perisinakis, K ;
Damilakis, J ;
Papadokostakis, G ;
Hadjipavlou, A ;
Gourtsoyiannis, N .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (09) :1698-1703
[9]  
[No title captured]