Efficiency of 4% icodextrin in preventing adhesions to spiral tacks used to fix intraperitoneal prostheses -: A sequential laparoscopy study

被引:9
作者
Bellon, J. M.
Rodriguez, M.
Garcia-Honduvilla, N.
Pascual, G.
Bujan, J.
机构
[1] Univ Alcala de Henares, Fac Med, Dept Surg, ES-28871 Madrid, Spain
[2] Univ Alcala de Henares, Fac Med, Dept Med Specialties, ES-28871 Madrid, Spain
关键词
adhesion formation; hernia; laparoscopy; peritoneal adhesions; wound healing; icodextrin; titanium spiral tacks;
D O I
10.1159/000095089
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background/Aims: This study was designed to evaluate the extent of adhesion formation to prostheses fixed with spiral tacks and to establish whether the use of Ringer's lactate or icodextrin could prevent these adhesions. Methods: 24 New Zealand white rabbits weighing around 3,000 g were implanted with a 7 ! 5 cm patch of ePTFE (DualMesh((R))) through a midline laparotomy. The prosthesis was fixed to the intact peritoneum using spiral tacks. Three study groups were established according to whether the animals were: implanted with ePTFE fixed with spiral tacks or implanted with ePTFE fixed with spiral tacks and simultaneously administered Ringer's lactate or 4% icodextrin in the peritoneal cavity. Adhesion formation and prosthetic behavior at the prosthesis/peritoneal interface were evaluated and quantified by sequential laparoscopy performed at 3, 7 and 14 days. Results: Adhesions generally formed on the tacks and were classified as the fully integrated type. No significant differences were observed in terms of the extent of adhesions or of neoperitoneal thickness between control animals and those receiving Ringer's lactate or icodextrin. Conclusions: (a) Prosthesis-fixing tacks induced adhesions; (b) the use of substances such as icodextrin or Ringer's lactate does not seem to diminish adhesion formation, and (c) the use of icodextrin offered no benefits over that of Ringer's lactate solution. Copyright (c) 2006 S. Karger AG, Basel.
引用
收藏
页码:458 / 463
页数:6
相关论文
共 20 条
[1]   PHOSPHATIDYLCHOLINE PREVENTS POSTOPERATIVE PERITONEAL ADHESIONS - AN EXPERIMENTAL-STUDY IN THE RAT [J].
ARRAJAB, A ;
AHREN, B ;
ROZGA, J ;
BENGMARK, S .
JOURNAL OF SURGICAL RESEARCH, 1991, 50 (03) :212-215
[2]   Experimental assay of a Dual Mesh(R) polytetrafluoroethylene prosthesis (non-porous on one side) in the repair of abdominal wall defects [J].
Bellon, JM ;
Contreras, LA ;
Bujan, J ;
Martin, ACS .
BIOMATERIALS, 1996, 17 (24) :2367-2372
[3]   Effect of phosphatidylcholine on the process of peritoneal adhesion following implantation of a polypropylene mesh prosthesis [J].
Bellon, JM ;
Contreras, LA ;
Bujan, J ;
Jurado, F .
BIOMATERIALS, 1996, 17 (14) :1369-1372
[4]   TNP-470 inhibits intraabdominal adhesion formation [J].
Chiang, SC ;
Cheng, CH ;
Moulton, KS ;
Kasznica, JM ;
Moulton, SL .
JOURNAL OF PEDIATRIC SURGERY, 2000, 35 (02) :189-196
[5]   Prevention of chemotherapy-induced intraperitoneal adhesion formation in rats by icodextrin at a range of concentrations [J].
Conroy, SE ;
Baines, L ;
Rodgers, K ;
Deviren, F ;
Verco, SJ .
GYNECOLOGIC ONCOLOGY, 2003, 88 (03) :304-308
[6]  
de Waart DR, 2001, PERITON DIALYSIS INT, V21, P269
[7]   Laparoscopic intraperitoneal polytetrafluoroethylene (PTFE) prosthetic patch repair of ventral hernia - Prospective comparison to open prefascial polypropylene mesh repair [J].
DeMaria, EJ ;
Moss, JM ;
Sugerman, HJ .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 2000, 14 (04) :326-329
[8]   A randomized, controlled pilot study of the safety and efficacy of 4% icodextrin solution in the reduction of adhesions following laparoscopic gynaecological surgery [J].
diZerega, GS ;
Verco, SJS ;
Young, P ;
Kettel, M ;
Kobak, W ;
Martin, D ;
Sanfilippo, J ;
Peers, EM ;
Scrimgeour, A ;
Brown, CB .
HUMAN REPRODUCTION, 2002, 17 (04) :1031-1038
[9]  
GILBERT JA, 1999, PERITON DIAL INT S1, V1, pS79
[10]   Evaluation of adhesion formation, mesh fixation strength, and hydroxyproline content after intraabdominal placement of polytetrafluoroethylene mesh secured using titanium spiral tacks, nitinol anchors, and polypropylene suture or polyglactin 910 suture [J].
Joels, CS ;
Matthews, BD ;
Kercher, KW ;
Austin, C ;
Norton, HJ ;
Williams, TC ;
Heniford, BT .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2005, 19 (06) :780-785