Digital subtraction in gadolinium-enhanced MR imaging of the brain: a method to reduce contrast dosage

被引:2
作者
Chan, JHM
Tsui, EYK
Chan, CY
Lai, KF
Chau, LF
Fong, D
Mok, CK
Cheung, YK
Wong, KPC
Yuen, MK
机构
[1] Tuen Mun Hosp, Dept Diagnost Radiol, Tuen Mun, Hong Kong, Peoples R China
[2] No Dist Hosp, Dept Diagnost Radiol, Hong Kong, Hong Kong, Peoples R China
[3] Tuen Mun Hosp, Dept Neurosurg, Tuen Mun, Hong Kong, Peoples R China
[4] Tuen Mun Hosp, Dept Med, Tuen Mun, Hong Kong, Peoples R China
关键词
digital subtraction; dose reduction; contrast-enhanced MRI; brain tumour; MR imaging;
D O I
10.1007/s00330-001-1285-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of the study was to investigate the feasibility of using digital subtraction in contrast-enhanced MR imaging of the brain to reduce the MR contrast dosage without jeopardizing patient care. Fifty-two patients with intracranial lesions, either intra-axial or extra-axial, detected by computerized tomography were selected for contrast-enhanced MR imaging with half-dose and full-dose of gadopentetate dimeglumine. The half-dose unsubtracted, full-dose unsubtracted, and half-dose subtracted MR images were visually assessed by counting the number of enhancing brain lesions in the images and quantitatively analyzed by computing their lesion contrast-to-background ratios (CBR). The visual conspicuity of the half-dose subtracted MR images was comparable to that of the full-dose unsubtracted MR images (p>0.05), whereas the CBR of the half-dose subtracted images was approximately two to three times higher than that of the full-dose unsubtracted images. The half-dose subtracted T1-weighted spin-echo images might be able to replace the conventional standard-dose T1-weighted spin-echo images in MR imaging of the brain.
引用
收藏
页码:2317 / 2321
页数:5
相关论文
共 20 条
[1]  
CURATI VL, 1996, NEURORADIOLOGY, V38, P713
[2]   Adverse events and cost savings three years after implementation of guidelines for outpatient contrast agent use [J].
Grant, KL ;
Camamo, JM .
AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 1997, 54 (12) :1395-1401
[3]   Use of half-dose gadolinium-enhanced MRI and magnetization transfer saturation in brain tumors [J].
Haba, D ;
Papon, AP ;
Tanguy, JY ;
Burtin, P ;
Aube, C ;
Caron-Poitreau, C .
EUROPEAN RADIOLOGY, 2001, 11 (01) :117-122
[4]   Half-dose gadolinium-enhanced MR imaging with magnetization transfer technique in brain tumors: Comparison with conventional contrast-enhanced MR imaging [J].
Han, D ;
Chang, KH ;
Han, MH ;
Cho, JY ;
Han, SW ;
Kim, HD ;
Seong, SO .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (01) :189-193
[5]  
HANNA SL, 1991, AM J NEURORADIOL, V12, P681
[6]   Contrast-enhanced magnetization transfer imaging: Improvement of brain tumor conspicuity and delineation for radiosurgical target volume definition [J].
Hawighorst, H ;
Debus, J ;
Schreiber, W ;
Knopp, MV ;
EngenhartCabillic, R ;
Essig, M ;
Brix, G ;
vanKaick, G .
RADIOTHERAPY AND ONCOLOGY, 1997, 43 (03) :261-267
[7]  
Hesselink J R, 1986, Acta Radiol Suppl, V369, P558
[8]   Field strength dependence of MRI contrast enhancement: Phantom measurements and application to dynamic breast imaging [J].
Hittmair, K ;
Turetschek, K ;
Gomiscek, G ;
Stiglbauer, R ;
Schurawitzki, H .
BRITISH JOURNAL OF RADIOLOGY, 1996, 69 (819) :215-220
[9]  
Knauth M, 1996, AM J NEURORADIOL, V17, P1853
[10]   Low-field interventional MRI in neurosurgery: finding the right dose of contrast medium [J].
Knauth, M ;
Wirtz, CR ;
Aras, N ;
Sartor, K .
NEURORADIOLOGY, 2001, 43 (03) :254-258