Determination of plutonium isotopes in waters and environmental solids: A review

被引:111
作者
Qiao, Jixin [1 ]
Hou, Xiaolin [1 ]
Miro, Manuel [2 ]
Roos, Per [1 ]
机构
[1] Tech Univ Denmark, Div Radiat Res, Riso Natl Lab Sustainable Energy, DK-4000 Roskilde, Denmark
[2] Univ Balearic Isl, Fac Sci, Dept Chem, E-07122 Palma de Mallorca, Illes Balears, Spain
关键词
Plutonium; Environment; Extraction chromatography; Ion exchange chromatography; Mass spectrometry; Radiometry; Flow analysis; Automation; PLASMA-MASS-SPECTROMETRY; HIGH-EFFICIENCY NEBULIZER; FLOW-INJECTION ANALYSIS; EXTRACTION CHROMATOGRAPHIC-SEPARATIONS; LIQUID SCINTILLATION SPECTROMETRY; LONG-LIVED RADIONUCLIDES; ICP-MS DETECTION; NAGASAKI A-BOMB; SEQUENTIAL-INJECTION; ALPHA-SPECTROMETRY;
D O I
10.1016/j.aca.2009.03.010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A number of analytical methods have been developed in the past few years for environmental monitoring of plutonium (Pu) isotopes around nuclear facilities within protocols for emergency preparedness as well as for risk assessment of contaminated areas resulting from nuclear weapon tests, nuclear accidents, and the discharge of nuclear waste. This article summarizes and critically compares recently reported methods for determination of Pu isotopes in waters and environmental solid substrates, in which sample pre-treatment is imperative for separation of the target species from matrix ingredients and/or potentially interfering nuclides prior to detection by radiometric or mass spectrometric techniques. Also discussed, via representative examples, is the automation of the entire analytical protocol by on-line extraction chromatography and ion exchange chromatography using flow injection (FI) or sequential injection (SI) approaches. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:66 / 84
页数:19
相关论文
共 135 条
[1]  
AARKROG A, 2000, RISER1243EN RIS NAT, P1
[2]   DETERMINATION OF PLUTONIUM BY ALPHA SPECTROMETRY [J].
AGGARWAL, SK ;
SAXENA, MK ;
JAIN, HC .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1992, 156 (01) :111-118
[3]  
[Anonymous], THESIS RISO NATL U
[4]   Recent Developments in Flow Injection/Sequential Injection Liquid-Liquid Extraction for Atomic Spectrometric Determination of Metals and Metalloids [J].
Anthemidis, Aristidis N. ;
Miro, Manuel .
APPLIED SPECTROSCOPY REVIEWS, 2009, 44 (02) :140-167
[5]  
*ATSDR, 2007, AGENCY TOXIC SUBSTAN, P151
[6]   Determination of rare earth elements in wine by inductively coupled plasma mass spectrometry using a microconcentric nebulizer [J].
Augagneur, S ;
Medina, B ;
Szpunar, J ;
Lobinski, R .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (09) :713-721
[7]   Radiochemical separation of actinides from environmental samples for determination with DF-ICP-MS and alpha spectrometry [J].
Ayranov, M ;
Krähenbühl, U ;
Sahli, H ;
Röllin, S ;
Burger, M .
RADIOCHIMICA ACTA, 2005, 93 (05) :249-257
[8]   Concentrations of 137Cs, 239,240Pu and 210Pb in sediment samples from the Pechora Sea and biological samples from the Ob, Yenisey Rivers and Kara Sea [J].
Baskaran, M ;
Asbill, S ;
Schwantes, J ;
Santschi, P ;
Champ, MA ;
Brooks, JM ;
Adkinson, D ;
Makeyev, V .
MARINE POLLUTION BULLETIN, 2000, 40 (10) :830-838
[9]   OBSERVATIONS ON PLUTONIUM IN THE OCEANS [J].
BAXTER, MS ;
FOWLER, SW ;
POVINEC, PP .
APPLIED RADIATION AND ISOTOPES, 1995, 46 (11) :1213-1223
[10]   Ultratrace and isotope analysis of long-lived radionuclides by inductively coupled plasma quadrupole mass spectrometry using a direct injection high efficiency nebulizer [J].
Becker, JS ;
Dietze, HJ ;
McLean, JA ;
Montaser, A .
ANALYTICAL CHEMISTRY, 1999, 71 (15) :3077-3084