MR1 detection of glycogen in vivo by using chemical exchange saturation transfer imaging (glycoCEST)

被引:327
作者
van Zijl, Peter C. M. [1 ]
Jones, Craig K.
Ren, Jimin
Malloy, Craig R.
Sherry, A. Dean
机构
[1] Johns Hopkins Med Inst, Div Magnet Resonance Res, Neurol Sect, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD 21205 USA
[2] Kennedy Krieger Inst, FM Kirby Res Ctr Funct Brain Imaging, Baltimore, MD 21205 USA
[3] Univ Texas, SW Med Ctr, Adv Imaging Res Ctr, Dallas, TX 75390 USA
[4] VA N Texas Hlth Care Syst, Dallas, TX 76216 USA
关键词
glucose; liver; water imaging; noninvasive;
D O I
10.1073/pnas.0700281104
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Detection of glycogen in vivo would have utility in the study of normal physiology and many disorders. Presently, the only magnetic resonance (MR) method available to study glycogen metabolism in Vivo is C-13 MR spectroscopy, but this technology is not routinely available on standard clinical scanners. Here, we show that glycogen can be detected indirectly through the water signal by using selective radio frequency (RF) saturation of the hydroxyl protons in the 0.5- to 1.5-ppm frequency range downfield from water. The resulting saturated spins are rapidly transferred to water protons via chemical exchange, leading to partial saturation of the water signal, a process now known as chemical exchange saturation transfer. This effect is demonstrated in glycogen phantoms at magnetic field strengths of 4.7 and 9.4 T, showing improved detection at higher field in adherence with MR exchange theory. Difference images obtained during RF irradiation at 1.0 ppm upfield and downfield of the water signal showed that glycogen metabolism could be followed in isolated, perfused mouse livers at 4.7 T before and after administration of glucagon. Glycogen breakdown was confirmed by measuring effluent glucose and, in separate experiments, by C-13 NMR spectroscopy. This approach opens the way to image the distribution of tissue glycogen in vivo and to monitor its metabolism rapidly and non-invasively with MRI.
引用
收藏
页码:4359 / 4364
页数:6
相关论文
共 40 条
[1]   Tunable imaging of cells labeled with MRI-PARACEST agents [J].
Aime, S ;
Carrera, C ;
Delli Castelli, D ;
Crich, SG ;
Terreno, E .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2005, 44 (12) :1813-1815
[2]   Paramagnetic lanthanide(III) complexes as pH-sensitive chemical exchange saturation transfer (CEST) contrast agents for MRI applications [J].
Aime, S ;
Barge, A ;
Delli Castelli, D ;
Fedeli, F ;
Mortillaro, A ;
Nielsen, FU ;
Terreno, E .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (04) :639-648
[3]   A paramagnetic MRI-CEST agent responsive to lactate concentration [J].
Aime, S ;
Delli Castelli, D ;
Fedeli, F ;
Terreno, E .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2002, 124 (32) :9364-9365
[4]   PROTON-DECOUPLED, OVERHAUSER-ENHANCED, SPATIALLY LOCALIZED C-13 SPECTROSCOPY IN HUMANS [J].
BOTTOMLEY, PA ;
HARDY, CJ ;
ROEMER, PB ;
MUELLER, OM .
MAGNETIC RESONANCE IN MEDICINE, 1989, 12 (03) :348-363
[5]   NMR-STUDIES OF H-1 NOES IN GLYCOGEN [J].
CHEN, W ;
AVISON, MJ ;
ZHU, XH ;
SHULMAN, RG .
BIOCHEMISTRY, 1993, 32 (43) :11483-11487
[6]   NUCLEAR-MAGNETIC-RESONANCE RELAXATION OF GLYCOGEN H1 IN SOLUTION [J].
CHEN, W ;
ZHU, XH ;
AVISON, MJ ;
SHULMAN, RG .
BIOCHEMISTRY, 1993, 32 (36) :9417-9422
[7]   Impaired glucose transport as a cause of decreased insulin-stimulated muscle glycogen synthesis in type 2 diabetes [J].
Cline, GW ;
Petersen, KF ;
Krssak, M ;
Shen, J ;
Hundal, RS ;
Trajanoski, Z ;
Inzucchi, S ;
Dresner, A ;
Rothman, DL ;
Shulman, GI .
NEW ENGLAND JOURNAL OF MEDICINE, 1999, 341 (04) :240-246
[8]   EVIDENCE FOR INCREASED LIVER-GLYCOGEN IN PATIENTS WITH NONINSULIN-DEPENDENT DIABETES-MELLITUS AFTER A 3-DAY FAST [J].
CLORE, JN ;
POST, EP ;
BAILEY, DJ ;
NESTLER, JE ;
BLACKARD, WG .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 1992, 74 (03) :660-666
[9]   Sensitive NMR detection of cationic-polymer-based gene delivery systems using saturation transfer via proton exchange [J].
Goffeney, N ;
Bulte, JWM ;
Duyn, J ;
Bryant, LH ;
van Zijl, PCM .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2001, 123 (35) :8628-8629
[10]   VALIDATION OF C-13 NMR MEASUREMENTS OF LIVER-GLYCOGEN IN-VIVO [J].
GRUETTER, R ;
MAGNUSSON, I ;
ROTHMAN, DL ;
AVISON, MJ ;
SHULMAN, RG ;
SHULMAN, GI .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (06) :583-588