Overview of the Chemcatcher® for the passive sampling of various pollutants in aquatic environments Part A: Principles, calibration, preparation and analysis of the sampler

被引:69
作者
Charriau, Adeline [1 ]
Lissalde, Sophie [1 ]
Poulier, Gaelle [1 ,2 ]
Mazzella, Nicolas [2 ]
Buzier, Remy [1 ]
Guibaud, Gilles [1 ]
机构
[1] Univ Limoges, Fac Sci & Tech, GRESE, F-87060 Limoges, France
[2] Grp Irstea Bordeaux, Unite Rech EABX, F-33612 Cestas, France
关键词
Freshwater; Micropollutants; Environmental monitoring; Passive sampling; Chemcatcher (R); Calibration; SEMIPERMEABLE-MEMBRANE DEVICES; CHEMICAL INTEGRATIVE SAMPLER; HYDROPHOBIC ORGANIC POLLUTANTS; GREAT-BARRIER-REEF; PERFORMANCE REFERENCE COMPOUNDS; IN-SITU CALIBRATION; ORGANOTIN COMPOUNDS; SEMIPOLAR PESTICIDES; MONITORING METALS; FIELD APPLICATION;
D O I
10.1016/j.talanta.2015.06.064
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The passive sampler Chemcatcher (R), which was developed in 2000, can be adapted for various types of water contaminants (e.g., trace metals, polycyclic aromatic hydrocarbons, pesticides and pharmaceutical residues) depending on the materials chosen for the receiving phase and the membrane. The Chemcatcher (R) has been used in numerous research articles in both laboratory experiments and field exposures, and here we review the state-of-the-art in applying this passive sampler. Part A of this review covers (1) the theory upon which the sampler is based (i.e., brief theory, calculation of water concentration, Performance and Reference Compounds), (2) the preparation of the device (i.e., sampler design, choice of the membrane and disk, mounting of the tool), and (3) calibration procedures (i.e., design of the calibration tank, tested parameters, sampling rates). (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:556 / 571
页数:16
相关论文
共 86 条
  • [1] AFNOR, 2011, 566723 NEI AFNOR NF, P38
  • [2] Calibration and use of the Chemcatcher® passive sampler for monitoring organotin compounds in water
    Aguilar-Martinez, R.
    Palacios-Corvillo, M. A.
    Greenwood, R.
    Mills, G. A.
    Vrana, B.
    Gomez-Gomez, M. M.
    [J]. ANALYTICA CHIMICA ACTA, 2008, 618 (02) : 157 - 167
  • [3] Application of Chemcatcher passive sampler for monitoring levels of mercury in contaminated river water
    Aguilar-Martinez, Rocio
    Milagros Gomez-Gomez, M.
    Greenwood, Richard
    Mills, Graham A.
    Vrana, Branislav
    Palacios-Corvillo, Maria A.
    [J]. TALANTA, 2009, 77 (04) : 1483 - 1489
  • [4] Assessment of Chemcatcher passive sampler for the monitoring of inorganic mercury and organotin compounds in water
    Aguilar-Martinez, Rocio
    Greenwood, Richard
    Mills, Graham A.
    Vrana, Branislav
    Palacios-Corvillo, Maria A.
    Gomez-Gomez, Maria M.
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2008, 88 (02) : 75 - 90
  • [5] Mercury and organotin compounds monitoring in fresh and marine waters across Europe by Chemcatcher passive sampler
    Aguilar-Martinez, Rocio
    Milagros Gomez-Gomez, M.
    Palacios-Corvillo, Maria A.
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2011, 91 (11) : 1100 - 1116
  • [6] Overview of passive Chemcatcher sampling with SPE pretreatment suitable for the analysis of NPEOs and NPs
    Ahkola, Heidi
    Herve, Sirpa
    Knuutinen, Juha
    [J]. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2013, 20 (03) : 1207 - 1218
  • [7] Chemcatcher® and DGT passive sampling devices for regulatory monitoring of trace metals in surface water
    Allan, Ian J.
    Knutsson, Jesper
    Guigues, Nathalie
    Mills, Graham A.
    Fouillac, Anne-Marie
    Greenwood, Richard
    [J]. JOURNAL OF ENVIRONMENTAL MONITORING, 2008, 10 (07): : 821 - 829
  • [8] Evaluation of the Chemcatcher and DGT passive samplers for monitoring metals with highly fluctuating water concentrations
    Allan, Ian J.
    Knutsson, Jesper
    Guigues, Nathalie
    Mills, Graham A.
    Fouillac, Anne-Marie
    Greenwood, Richard
    [J]. JOURNAL OF ENVIRONMENTAL MONITORING, 2007, 9 (07): : 672 - 681
  • [9] Short-term exposure testing of six different passive samplers for the monitoring of hydrophobic contaminants in water
    Allan, Ian J.
    Booij, Kees
    Paschke, Albrecht
    Vrana, Branislav
    Mills, Graham A.
    Greenwood, Richard
    [J]. JOURNAL OF ENVIRONMENTAL MONITORING, 2010, 12 (03): : 696 - 703
  • [10] Field Performance of Seven Passive Sampling Devices for Monitoring of Hydrophobic Substances
    Allan, Ian J.
    Booij, Kees
    Paschke, Albrecht
    Vrana, Branislav
    Mills, Graham A.
    Greenwood, Richard
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2009, 43 (14) : 5383 - 5390