Effect of the aerobic capacity on the validity of the anaerobic threshold for determination of the maximal lactate steady state in cycling

被引:45
作者
Denadai, BS
Figuera, TR
Favaro, ORP
Gonçalves, M
机构
[1] UNESP, IB, Lab Avaliacao Performance Huamana, BR-13506900 Rio Claro, SP, Brazil
[2] UNESP, IB, Lab Biomecan, BR-13506900 Rio Claro, SP, Brazil
关键词
anaerobic threshold; lactate steady state; aerobic capacity; cycling;
D O I
10.1590/S0100-879X2004001000015
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The maximal lactate steady state (MLSS) is the highest blood lactate concentration that can be identified as maintaining a steady state during a prolonged submaximal constant workload. The objective of the present study was to analyze the influence of the aerobic capacity on the validity of anaerobic threshold (AT) to estimate the exercise intensity at MLSS (MLSS intensity) during cycling. Ten untrained males (UC) and 9 male endurance cyclists (EC) matched for age, weight and height performed one incremental maximal load test to determine AT and two to four 30-min constant submaximal load tests on a mechanically braked cycle ergometer to determine MLSS and MLSS intensity. AT was determined as the intensity corresponding to 3.5 mM blood lactate. MLSS intensity was defined as the highest workload at which blood lactate concentration did not increase by more than 1 mM between minutes 10 and 30 of the constant workload. MLSS intensity (EC = 282.1 +/- 23.8 W; UC = 180.2 +/- 24.5 W) and AT (EC = 274.8 +/- 24.9 W; UC = 187.2 +/- 28.0 W) were significantly higher in trained group. However, there was no significant difference in MLSS between EC (5.0 +/- 1.2 mM) and UC (4.9 +/- 1.7 mM). The MLSS, intensity and AT were not different and significantly correlated in both groups (EC: r = 0.77; UC: r = 0.81). We conclude that MLSS and the validity of AT to estimate MLSS intensity during cycling, analyzed in a cross-sectional design (trained x sedentary), do not depend on the aerobic capacity.
引用
收藏
页码:1551 / 1556
页数:6
相关论文
共 20 条
[11]  
Gaesser G A, 1996, Exerc Sport Sci Rev, V24, P35
[12]   JUSTIFICATION OF THE 4-MMOL/I LACTATE THRESHOLD [J].
HECK, H ;
MADER, A ;
HESS, G ;
MUCKE, S ;
MULLER, R ;
HOLLMANN, W .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1985, 6 (03) :117-130
[13]  
Heck H., 1990, Laktat in Der Leistungsdiagnostik
[14]   Effect of training on lactate/ventilatory thresholds: A meta-analysis [J].
Londeree, BR .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1997, 29 (06) :837-843
[15]   PHYSIOLOGICAL-RESPONSES DURING PROLONGED EXERCISE AT THE POWER OUTPUT CORRESPONDING TO THE BLOOD LACTATE THRESHOLD [J].
MOGNONI, P ;
SIRTORI, MD ;
LORENZELLI, F ;
CERRETELLI, P .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1990, 60 (04) :239-243
[16]   Maximal lactate steady state, critical power and EMG during cycling [J].
Pringle, JSM ;
Jones, AM .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2002, 88 (03) :214-226
[17]   Blood glucose responses in humans mirror lactate responses for individual anaerobic threshold and for lactate minimum in track tests [J].
Simoes, HG ;
Campbell, CSG ;
Kokubun, E ;
Denadai, BS ;
Baldissera, V .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1999, 80 (01) :34-40
[18]  
SIMON G, 1981, DTSCH Z SPORTMED, V32, P7
[19]   LACTATE KINETICS AND INDIVIDUAL ANAEROBIC THRESHOLD [J].
STEGMANN, H ;
KINDERMANN, W ;
SCHNABEL, A .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1981, 2 (03) :160-165
[20]   INDIVIDUAL ANAEROBIC THRESHOLD AND MAXIMUM LACTATE STEADY-STATE [J].
URHAUSEN, A ;
COEN, B ;
WEILER, B ;
KINDERMANN, W .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1993, 14 (03) :134-139