Comparative dosimetric study of three-dimensional conformal, dynamic conformal arc, and intensity-modulated radiotherapy for brain tumor treatment using novalis system

被引:31
作者
Ding, Meisong [1 ]
Newman, Francis [1 ]
Kavanagh, Brian D. [1 ]
Stuhr, Kelly [1 ]
Johnson, Tim K. [1 ]
Gaspar, Laurie E. [1 ]
机构
[1] Univ Colorado, Hlth Sci Ctr, Dept Radiat Oncol, Aurora, CO 80045 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2006年 / 66卷 / 04期
关键词
dosimetric comparison; three-dimensional conformal radiotherapy; dynamic arc radiotherapy; intensity-modulated radiotherapy;
D O I
10.1016/j.ijrobp.2005.09.009
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To investigate the dosimetric differences among three-dimensional conformal radiotherapy (3D-CRT), dynamic conformal arc therapy (DCAT), and intensity-modulated radiotherapy (IMRT) for brain tumor treatment. Methods and Materials: Fifteen patients treated with Novalis were selected. We performed 3D-CRT, DCAT, and 1MRT plans for all patients. The margin for the planning target volume (PTV) was 1 mm, and the specific prescription dose was 90% for all plans. The target coverage at the prescription dose, conformity index (CI), and heterogeneity index were analyzed for all plans. Results: For small tumors (PTV <= 2 cm(3)), the three dosimetric parameters had approximate values for both 3D-CRT and DCAT plans. The CI for the IMRT plans was high. For medium tumors (PTV > 2 to <= 100 cm(3)), the three plans were competitive with each other. The IMRT plans had a greater CI, better target coverage at the prescription dose, and a better heterogeneity index. For large tumors (PTV > 100 cm(3)), the IMRT plan had good target coverage at the prescription dose and heterogeneity index and approximate CI values as those in the 3D-CRT and DCAT plans. Conclusion: The results of our study have shown that DCAT is suitable for most cases in the treatment of brain tumors. For a small target, 3D-CRT is useful, and IMRT is not recommended. For larger tumors, IMRT is superior to 3D-CRT and very competitive in sparing critical structures, especially for big tumors. (c) 2006 Elsevier Inc.
引用
收藏
页码:S82 / S86
页数:5
相关论文
共 17 条
[1]   Intensity-modulated stereotactic radiotherapy vs. stereotactic conformal radiotherapy for the treatment of meningioma located predominantly in the skull base [J].
Baumert, BG ;
Norton, IA ;
Davis, JB .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 57 (02) :580-592
[2]   STATIC-FIELD CONFORMAL STEREOTAXIC RADIOSURGERY - PHYSICAL TECHNIQUES [J].
BOURLAND, JD ;
MCCOLLOUGH, KP .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (02) :471-479
[3]   A comparison of three stereotactic radiotherapy techniques; arcs vs. noncoplanar fixed fields vs. intensity modulation [J].
Cardinale, RM ;
Benedict, SH ;
Wu, QW ;
Zwicker, RD ;
Gaballa, HE ;
Mohan, R .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (02) :431-436
[4]  
EARL TA, 2001, INT J RADIAT ONCOL, V51, P405
[5]   Implementing IMRT in clinical practice: A joint document of the American Society for Therapeutic Radiology and Oncology and the American Association of Physicists in Medicine [J].
Galvin, JM ;
Ezzell, G ;
Eisbrauch, A ;
Yu, C ;
Butler, B ;
Xiao, Y ;
Rosen, I ;
Rosenman, J ;
Sharpe, M ;
Xing, L ;
Xia, P ;
Lomax, T ;
Low, DA ;
Palta, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 58 (05) :1616-1634
[6]   Dynamic arc radiosurgery and radiotherapy: Commissioning and verification of dose distributions [J].
Grebe, G ;
Pfaender, M ;
Roll, M ;
Luedemann, L .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (05) :1451-1460
[7]   Comparison of static conformal field with multiple noncoplanar arc techniques for stereotactic radiosurgery or stereotactic radiotherapy [J].
Hamilton, RJ ;
Kuchnir, FT ;
Sweeney, P ;
Rubin, SJ ;
Dujovny, M ;
Pelizzari, CA ;
Chen, GTY .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1221-1228
[8]   A comparison of arc-based and static mini-multileaf collimator-based radiosurgery treatment plans [J].
Kubo, HD ;
Pappas, CTE ;
Wilder, RB .
RADIOTHERAPY AND ONCOLOGY, 1997, 45 (01) :89-93
[9]   STEREOTAXIC RADIOTHERAPY OF IRREGULAR TARGETS - A COMPARISON BETWEEN STATIC CONFORMAL BEAMS AND NONCOPLANAR ARCS [J].
LAING, RW ;
BENTLEY, RE ;
NAHUM, AE ;
WARRINGTON, AP ;
BRADA, M .
RADIOTHERAPY AND ONCOLOGY, 1993, 28 (03) :241-246
[10]  
Li X. A., 2000, International Journal of Radiation Oncology Biology Physics, V48, P219, DOI 10.1016/S0360-3016(00)80233-3