Pulmonary Venous Wedge Pressure Provides a Safe and Accurate Estimate of Pulmonary Arterial Pressure in Children with Shunt-Dependent Pulmonary Blood Flow

被引:4
作者
Hill, Kevin D. [1 ]
Janssen, Dana [1 ]
Ohmstede, David P. [2 ]
Doyle, Thomas P. [1 ]
机构
[1] Monroe Carell Jr Childrens Hosp Vanderbilt, Div Pediat Cardiol, Nashville, TN 37232 USA
[2] Presbyterian Pediat Cardiol, Charlotte, NC USA
关键词
pulmonary artery pressure; shunt; single ventricle; SINGLE VENTRICLE;
D O I
10.1002/ccd.22084
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: To compare two methods of pulmonary arterial pressure measurement in children with shunt-dependent pulmonary blood flow. Background: In children with shunt-dependent pulmonary blood flow, direct assessment of pulmonary arterial pressure requires passage of a catheter across the shunt. This can be technically difficult and dangerous. Use of the pulmonary venous wedge pressure offers an alternative but has not been validated in this patient population. Methods: We prospectively studied 18 children with shunt-dependent pulmonary blood flow. Pulmonary venous wedge pressure and directly measured pulmonary arterial pressures were independently assessed by two blinded cardiologists. Results: Directly measured mean pulmonary arterial pressure and pulmonary venous wedge pressure are closely correlated (R-2 = 0.80, P < 0.01). Agreement between the two measures is improved at lower mean pressures with greater differences at higher pressures. For 20 of 24 ipsilateral measurements, pulmonary various wedge pressure was >= directly measured pulmonary arterial pressure. Pulmonary venous wedge pressure never underestimated pulmonary arterial pressure by more than 3 mm Hg. Conclusions: Pulmonary venous wedge pressure provides a safe and accurate means of estimating pulmonary arterial pressure in children with shunt-dependent pulmonary blood flow. The slightly lower pressures seen on direct measurement compared with the reverse pulmonary vein may reflect impairment of flow across the shunt by the catheter. (C) 2009 Wiley-Liss, Inc.
引用
收藏
页码:747 / 752
页数:6
相关论文
共 17 条
[1]   FACTORS INFLUENCING SURVIVAL IN PATIENTS UNDERGOING THE BIDIRECTIONAL GLENN ANASTOMOSIS [J].
ALEJOS, JC ;
WILLIAMS, RG ;
JARMAKANI, JM ;
GALINDO, AJ ;
ISABELJONES, JB ;
DRINKWATER, D ;
LAKS, H ;
KAPLAN, S .
AMERICAN JOURNAL OF CARDIOLOGY, 1995, 75 (15) :1048-1050
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Cardiac magnetic resonance versus routine cardiac catheterization before bidirectional Glenn anastomosis in infants with functional single ventricle: A prospective randomized trial [J].
Brown, David W. ;
Gauvreau, Kimberlee ;
Powell, Andrew J. ;
Lang, Peter ;
Colan, Steven D. ;
del Nido, Pedro J. ;
Odegard, Kirsten C. ;
Geva, Tal .
CIRCULATION, 2007, 116 (23) :2718-2725
[5]   ESTIMATION OF PULMONARY-ARTERY PRESSURE FROM PULMONARY VEIN WEDGE PRESSURE [J].
CHERN, MS ;
YEH, SJ ;
LIN, FC ;
WU, DL ;
HUNG, JS .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1994, 31 (04) :277-282
[6]   5-YEAR TO 15-YEAR FOLLOW-UP AFTER FONTAN OPERATION [J].
DRISCOLL, DJ ;
OFFORD, KP ;
FELDT, RH ;
SCHAFF, HV ;
PUGA, FJ ;
DANIELSON, GK .
CIRCULATION, 1992, 85 (02) :469-496
[7]  
HAWKER RE, 1973, BRIT HEART J, V35, P386
[8]   OBSTRUCTION OF SYSTEMIC PULMONARY ARTERIAL SHUNTS BY DIAGNOSTIC CARDIAC CATHETERS [J].
LLOYD, TR ;
DONNERSTEIN, RL ;
SHIRAZI, F .
AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (10) :878-880
[9]   Computational model of the fluid dynamics in systemic-to-pulmonary shunts [J].
Migliavacca, F ;
Dubini, G ;
Pennati, G ;
Pietrabissa, R ;
Fumero, R ;
Hsia, TY ;
de Leval, MR .
JOURNAL OF BIOMECHANICS, 2000, 33 (05) :549-557
[10]   Modeling of the Norwood circulation: effects of shunt size, vascular resistances, and heart rate [J].
Migliavacca, F ;
Pennati, G ;
Dubini, G ;
Fumero, R ;
Pietrabissa, R ;
Urcelay, G ;
Bove, EL ;
Hsia, TY ;
De Leval, MR .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2001, 280 (05) :H2076-H2086