USE OF CO2 CONCENTRATION DIFFERENCE OR CO2 BALANCE TO ASSESS VENTILATION RATE OF BROILER HOUSES

被引:1
作者
Xin, H. [1 ]
Li, H. [1 ]
Burns, R. T. [1 ]
Gates, R. S. [2 ]
Overhults, D. G. [3 ]
Earnest, J. W. [3 ]
机构
[1] Iowa State Univ, Dept Agr & Biosyst Engn, Ames, IA 50011 USA
[2] Univ Illinois, Dept Agr & Biol Engn, Urbana, IL 61801 USA
[3] Univ Kentucky, Dept Biosyst & Agr Engn, Res & Educ Ctr, Princeton, KY USA
关键词
Air emissions; Indirect animal calorimetry; Metabolic rate; Natural ventilation; MEASURING EMISSION RATES; LIVESTOCK BUILDINGS; MANURE STORES; AMMONIA; SLURRY;
D O I
暂无
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
Ventilation rate (VR) is one of the two key elements for quantifying aerial emissions from animal production facilities. Direct, continuous measurement of building VR can be challenging and impractical under certain circumstances, e.g., naturally ventilated animal housing or a large number of ventilation fans in the building. This study examined the suitability of estimating VR of broiler houses with built-up litter (mixture of manure and bedding), when supplemental heating was not in use, through either carbon dioxide (CO2) balance or the relationship of VR to CO2 concentration difference between exhaust and inlet air. The reference VR was based our direct measurement by continuously monitoring operation of the in-situ calibrated exhaust fans. The comparative analysis of the direct method vs. each indirect method was conducted for a measurement integration time (MIT) of 10, 30, 60, or 120 min. The analyses revealed that MIT of 30 min or greater resulted in non-significant differences in VR between the indirect and direct methods. The broiler building VR (m(3) s(-1)) may be related to the exhaust-inlet CO2 concentration difference (Delta CO2, ppm) as VR (+/- 3.0) = 4456 (+/- 41) Delta CO2-0.786(+/- 0.019) at 30 min MIT. The VR may also be determined by the CO2 balance method (including litter CO2 generation) with a correction factor of 0.97 at MIT of 30 to 120 min. If litter CO2 generation is omitted from the total building CO2 production, the actual VR may be estimated by applying a correction factor of 1.077 to the bird respiration CO2 balance VR. Hence, the CO2 balance or concentration difference method offers a viable alternative or supplemental check for quantifying building VR under certain conditions where direct, continuous VR measurement is not feasible.
引用
收藏
页码:1353 / 1361
页数:9
相关论文
共 18 条
[1]  
Brouwer E., 1965, ENERGY METABOLISM, P441, DOI DOI 10.4236/NS.2011.312129
[2]  
Burns RT, 2007, P INT S AIR QUAL WAS
[3]  
BURNS RT, 2006, P S AIR QUAL MEAS ME
[4]  
FEDDES JJR, 1984, CAN AGR ENG, V26, P53
[5]  
Gates RS, 2009, T ASABE, V52, P1345, DOI 10.13031/2013.27784
[6]  
Gates RS, 2004, T ASAE, V47, P1709, DOI 10.13031/2013.17613
[7]  
Li H, 2005, T ASAE, V48, P367, DOI 10.13031/2013.17950
[8]  
Moody L., 2008, QUALITY ASSURANCE PR
[9]  
MUHLBAUER RV, 2006, 064159 ASABE
[10]   A comparison of three balance methods for calculating ventilation rates in livestock buildings [J].
Pedersen, S ;
Takai, H ;
Johnsen, JO ;
Metz, JHM ;
Koerkamp, PWGG ;
Uenk, GH ;
Phillips, VR ;
Holden, MR ;
Sneath, RW ;
Short, JL ;
White, RP ;
Hartung, J ;
Seedorf, J ;
Schroder, M ;
Linkert, KH ;
Wathes, CM .
JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 1998, 70 (01) :25-37