Phase and amplitude sensitivities in surface plasmon resonance bio and chemical sensing

被引:237
作者
Kabashin, Andrei V. [1 ]
Patskovsky, Sergiy [2 ]
Grigorenko, Alexander N. [3 ]
机构
[1] Univ Mediterranee, Lab Lasers Plasmas & Procedes Photon, UMR 6182, CNRS,Fac Sci Luminy, F-13288 Marseille, France
[2] Ecole Polytech, Dept Engn Phys, Montreal, PQ H3C 3A7, Canada
[3] Univ Manchester, Dept Phys & Astron, Manchester M13 9PL, Lancs, England
基金
英国工程与自然科学研究理事会;
关键词
SENSOR; INTERFEROMETRY; INTERROGATION; POLARIMETRY; SPR;
D O I
10.1364/OE.17.021191
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We consider amplitude and phase characteristics of light reflected under the Surface Plasmon Resonance (SPR) conditions and study their sensitivities to refractive index changes associated with biological and chemical sensing. Our analysis shows that phase can provide at least two orders of magnitude better detection limit due to the following reasons: (i) Maximal phase changes occur in the very dip of the SPR curve where the vector of probing electric field is maximal, whereas maximal amplitude changes are observed on the resonance slopes: this provides a one order of magnitude larger sensitivity of phase to refractive index variations; (ii) Under a proper design of a detection scheme, phase noises can be orders of magnitude lower compared to amplitude ones, which results in a much better signal-to-noise ratio; (iii) Phase offers much better possibilities for signal averaging and filtering, as well as for image treatment. Applying a phase-sensitive SPR polarimetry scheme and using gas calibration model, we experimentally demonstrate the detection limit of 10(-8) RIU, which is about two orders of magnitude better compared to amplitude-sensitive schemes. Finally, we show how phase can be employed for filtering and treatment of images in order to improve signal-to-noise ratio even in relatively noisy detection schemes. Combining a much better physical sensitivity and a possibility of imaging and sensing in micro-arrays, phase-sensitive methodologies promise a substantial upgrade of currently available SPR technology. (C) 2009 Optical Society of America
引用
收藏
页码:21191 / 21204
页数:14
相关论文
共 65 条
[1]   SURFACE ELECTROMAGNETIC-WAVES ELLIPSOMETRY [J].
ABELES, F .
SURFACE SCIENCE, 1976, 56 (01) :237-251
[2]   Biosensor based on surface plasmon interferometry independent on variations of liquid's refraction index [J].
Alieva, E ;
Konopsky, VN .
SENSORS AND ACTUATORS B-CHEMICAL, 2004, 99 (01) :90-97
[3]  
[Anonymous], 2003, OPTICAL COMMUNICATIO
[4]   Laser stabilisation for the measurement of thermal noise [J].
Baigent, KG ;
Shaddock, DA ;
Gray, MB ;
McClelland, DE .
GENERAL RELATIVITY AND GRAVITATION, 2000, 32 (03) :399-409
[5]  
Born M., 2002, Principles of Optics
[6]   High-resolution angular measurement using surface-plasmon-resonance via phase interrogation at optimal incident wavelengths [J].
Chiang, HP ;
Lin, JL ;
Chang, RL ;
Su, SY ;
Leung, PT .
OPTICS LETTERS, 2005, 30 (20) :2727-2729
[7]   Characteristics of a paired surface plasma waves biosensor [J].
Chou, Chien ;
Wu, Hsieh-Ting ;
Huang, Yen-Chen ;
Chen, Yi-Ling ;
Kuo, Wen-Chuan .
OPTICS EXPRESS, 2006, 14 (10) :4307-4315
[8]   Phase jumps and interferometric surface plasmon resonance imaging [J].
Grigorenko, AN ;
Nikitin, PI ;
Kabashin, AV .
APPLIED PHYSICS LETTERS, 1999, 75 (25) :3917-3919
[9]   Dark-field surface plasmon resonance microscopy [J].
Grigorenko, AN ;
Beloglazov, AA ;
Nikitin, PI ;
Kuhne, C ;
Steiner, G ;
Salzer, R .
OPTICS COMMUNICATIONS, 2000, 174 (1-4) :151-155
[10]  
HALL JL, 2006, Patent No. 7233396