Modeling of the steel-concrete push-out test

被引:12
|
作者
Bouchair, A. [1 ]
Bujnak, J. [2 ]
Duratna, P. [1 ,2 ]
Lachal, A. [3 ]
机构
[1] Univ Blaise Pascal, Lami, BP 206, F-63000 Clermont Ferrand, France
[2] Univ Zilina, Fac Civil Engn, Dept Struct & Bridges, Zilina 01026, Czech Republic
[3] INSA, LGCGM, Struct Engn Res Grp, Rennes, France
关键词
Finite element; Stud connector; Slip; Push-out test;
D O I
10.1016/j.proeng.2012.07.063
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In steel-concrete composite structures, the behavior of the shear connections is of a great importance. This behavior is generally characterized by the load-slip curve obtained from experimental push-out tests, however expensive and time-consuming. In this study, a numerical model is developed to represent the behavior of a push-out test. The theoretical model considers the non linear behavior of steel and concrete of the modeled specimens. The model is validated on the basis of experimental results from 4 push-out tests with samples using headed studs. The real behavior of the studs was simulated by a three-dimensional quarter-scale finite element model using software ATENA. The finite element calculation can represent well the real behavior of the push-out test. Then, the model has been used for further parametric analysis with flange thickness and different spacing of the studs. (c) 2012 Published by Elsevier Ltd. Selection and review under responsibility of University of Zilina, FCE, Slovakia.
引用
收藏
页码:102 / 107
页数:6
相关论文
共 50 条
  • [21] Cohesive Zone Model Based Numerical Analysis of Steel-Concrete Composite Structure Push-Out Tests
    Lin, J. P.
    Wang, J. F.
    Xu, R. Q.
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2014, 2014
  • [22] Push-out strength of concrete plugs in tubular steel piles
    Nezamian, A
    Al-Mahaidi, R
    Grundy, P
    O'Loughlin, B
    PROCEEDINGS OF THE TWELFTH (2002) INTERNATIONAL OFFSHORE AND POLAR ENGINEERING CONFERENCE, VOL 4, 2002, : 60 - 64
  • [23] Analysis Method of Bearing Capacity of Stud Connector in Steel-concrete Composite Structures Under Push-out Failure
    Pu Q.
    Xie H.
    Fan S.
    Wang W.
    Liu J.
    Gou H.
    Gongcheng Kexue Yu Jishu/Advanced Engineering Sciences, 2019, 51 (01): : 89 - 95
  • [24] Analysis on the behaviors of bond-slip between the shape steel and the concrete by push-out test
    Xue, Jian-Yang
    Zhao, Hong-Tie
    Yang, Yong
    Wu, Jian-Bin
    Wu, Kai
    Chen, Zong-Ping
    Xi'an Jianzhu Keji Daxue Xuebao/Journal of Xi'an University of Architecture and Technology, 2007, 39 (03): : 320 - 326
  • [25] Push-Out Test on Low-Density Concrete Filled Stiffened Steel Tubular Columns
    S. Sindhuja
    P. Bhuvaneshwari
    International Journal of Civil Engineering, 2021, 19 : 1399 - 1413
  • [26] Push-Out Test on Low-Density Concrete Filled Stiffened Steel Tubular Columns
    Sindhuja, S.
    Bhuvaneshwari, P.
    INTERNATIONAL JOURNAL OF CIVIL ENGINEERING, 2021, 19 (12) : 1399 - 1413
  • [27] FINITE ELEMENT MODELLING OF PUSH-OUT TESTS FOR BUBBLE DECK SYSTEM INCORPORATING INTO COMPOSITE STEEL-CONCRETE BEAMS
    Tan, E. L.
    Sisay, J.
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON STEEL AND ALUMINIUM STRUCTURES (ICSAS19), 2019, : 777 - 783
  • [28] FEM analysis of push-out test response of Hybrid Steel Trussed Concrete Beams (HSTCBs)
    Colajanni, Piero
    La Mendola, Lidia
    Latour, Massimo
    Monaco, Alessia
    Rizzano, Gianvittorio
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2015, 111 : 88 - 102
  • [29] Push-out tests for perfobond strip connectors with UHPC grout in the joints of steel-concrete hybrid bridge girders
    He, Shaohua
    Fang, Zhi
    Mosallam, Ayman S.
    ENGINEERING STRUCTURES, 2017, 135 : 177 - 190
  • [30] Push-out tests on steel sections encased in steel fibre reinforced concrete
    Zanon, Riccardo
    Schaefer, Markus
    Paoletti, Maxence
    Ruiz, Gonzalo
    de la Rosa, Angel
    Wolf, Sebastien
    STEEL CONSTRUCTION-DESIGN AND RESEARCH, 2025,